JR28 Thermal Overload Relay LRD LR2-D13 0.1A–25A

JR28 Thermal Overload Relay is used for AC motor overload protection in motor control circuits. It supports adjustable current settings, manual or automatic reset, test and stop buttons, and 1NO+1NC auxiliary contacts. Compatible with LRD and LR2-D13 type applications, it is suitable for pumps, fans, compressors, HVAC systems and industrial control panels.

JR28 Thermal Overload Relay LRD LR2-D13 0.1A–25A

Select the number of specifications

Please check the product information you want!

Key Features Technical Specifications Model Selection Reference FAQ

1. Motor Overload Protection

Protects motors from long-time overload operation and helps reduce motor burning risk.

2. Adjustable Current Setting

The rated current can be adjusted according to the motor operating current, making selection and installation more flexible.

3. Manual / Automatic Reset

Supports manual and automatic reset options for different control circuit requirements.

4. Test and Stop Button

Equipped with test and stop buttons for convenient maintenance and function checking.

5. NO / NC Auxiliary Contacts

Includes normally open and normally closed auxiliary contacts for control circuit connection.

6. Stable and Durable Structure

Compact structure with selected materials for stable operation and long service life.

7. Copper Conductive Pins

Pure copper pins provide better conductivity and more stable operation.


ItemSpecification
Product NameThermal Overload Relay
ModelJR28
Compatible TypeLRD / LR2-D13
Rated Insulation Voltage660V
Current Range0.1A–25A
Common Frame Current25A / 63A / 93A
Trip Class10A
Protection FunctionMotor overload protection
Reset ModeManual / Automatic reset
Contact Form1NO + 1NC
Auxiliary Contact95-96 NC, 97-98 NO
StandardIEC60947-4-1 / GB14048.4
ApplicationAC motor protection, pump, fan, compressor, control panel


Model Range              Current Range                     Suitable Application
JR28-250.1A–25A              Small and medium motor protection
JR28-6325A–63A              Medium motor control systems
JR28-9363A–93A              Larger motor control systems

Common JR28-25 current ranges include:

Model                                            Adjustable Current Range
JR28-25 0.1–0.16A0.1–0.16A
JR28-25 0.16–0.25A0.16–0.25A
JR28-25 0.25–0.4A0.25–0.4A
JR28-25 0.4–0.63A0.4–0.63A
JR28-25 0.63–1A0.63–1A
JR28-25 1–1.6A1–1.6A
JR28-25 1.6–2.5A1.6–2.5A
JR28-25 2.5–4A2.5–4A
JR28-25 4–6A4–6A
JR28-25 5.5–8A5.5–8A
JR28-25 7–10A7–10A
JR28-25 9–13A9–13A
JR28-25 12–18A12–18A
JR28-25 17–25A17–25A


Q1: What is the JR28 thermal overload relay used for?

A: It is used to protect AC motors from overload and long-time overcurrent operation.

Q2: Can it be used with CJX2 AC contactors?

A: Yes, it is commonly used together with CJX2 AC contactors for motor control circuits.

Q3: What current range is available?

A: JR28-25 supports adjustable current ranges from 0.1A to 25A.

Q4: Does it have auxiliary contacts?

A: Yes, it has 1 normally open and 1 normally closed auxiliary contact.

Q5: Does it support manual reset?

A: Yes, it supports manual and automatic reset options.

Q6: Is it a replacement for LRD or LR2-D13 type relays?

A: It can be used as a compatible replacement in many LRD and LR2-D13 thermal relay applications.

Q7: What applications is it suitable for?

A: It is suitable for pumps, fans, compressors, HVAC equipment, motor control cabinets and industrial machinery.

Q8: Can it be supplied together with AC contactors?

A: Yes, we can supply it together with CJX2 AC contactors as a complete motor control solution.


No comment

Key Features

1. Motor Overload Protection

Protects motors from long-time overload operation and helps reduce motor burning risk.

2. Adjustable Current Setting

The rated current can be adjusted according to the motor operating current, making selection and installation more flexible.

3. Manual / Automatic Reset

Supports manual and automatic reset options for different control circuit requirements.

4. Test and Stop Button

Equipped with test and stop buttons for convenient maintenance and function checking.

5. NO / NC Auxiliary Contacts

Includes normally open and normally closed auxiliary contacts for control circuit connection.

6. Stable and Durable Structure

Compact structure with selected materials for stable operation and long service life.

7. Copper Conductive Pins

Pure copper pins provide better conductivity and more stable operation.


Technical Specifications
ItemSpecification
Product NameThermal Overload Relay
ModelJR28
Compatible TypeLRD / LR2-D13
Rated Insulation Voltage660V
Current Range0.1A–25A
Common Frame Current25A / 63A / 93A
Trip Class10A
Protection FunctionMotor overload protection
Reset ModeManual / Automatic reset
Contact Form1NO + 1NC
Auxiliary Contact95-96 NC, 97-98 NO
StandardIEC60947-4-1 / GB14048.4
ApplicationAC motor protection, pump, fan, compressor, control panel


Model Selection Reference
Model Range              Current Range                     Suitable Application
JR28-250.1A–25A              Small and medium motor protection
JR28-6325A–63A              Medium motor control systems
JR28-9363A–93A              Larger motor control systems

Common JR28-25 current ranges include:

Model                                            Adjustable Current Range
JR28-25 0.1–0.16A0.1–0.16A
JR28-25 0.16–0.25A0.16–0.25A
JR28-25 0.25–0.4A0.25–0.4A
JR28-25 0.4–0.63A0.4–0.63A
JR28-25 0.63–1A0.63–1A
JR28-25 1–1.6A1–1.6A
JR28-25 1.6–2.5A1.6–2.5A
JR28-25 2.5–4A2.5–4A
JR28-25 4–6A4–6A
JR28-25 5.5–8A5.5–8A
JR28-25 7–10A7–10A
JR28-25 9–13A9–13A
JR28-25 12–18A12–18A
JR28-25 17–25A17–25A


FAQ

Q1: What is the JR28 thermal overload relay used for?

A: It is used to protect AC motors from overload and long-time overcurrent operation.

Q2: Can it be used with CJX2 AC contactors?

A: Yes, it is commonly used together with CJX2 AC contactors for motor control circuits.

Q3: What current range is available?

A: JR28-25 supports adjustable current ranges from 0.1A to 25A.

Q4: Does it have auxiliary contacts?

A: Yes, it has 1 normally open and 1 normally closed auxiliary contact.

Q5: Does it support manual reset?

A: Yes, it supports manual and automatic reset options.

Q6: Is it a replacement for LRD or LR2-D13 type relays?

A: It can be used as a compatible replacement in many LRD and LR2-D13 thermal relay applications.

Q7: What applications is it suitable for?

A: It is suitable for pumps, fans, compressors, HVAC equipment, motor control cabinets and industrial machinery.

Q8: Can it be supplied together with AC contactors?

A: Yes, we can supply it together with CJX2 AC contactors as a complete motor control solution.


JR28 Thermal Overload Relay LRD LR2-D13 0.1A–25A
JR28 Thermal Overload Relay is used for AC motor overload protection in motor control circuits. It supports adjustable current settings, manual or automatic reset, test and stop buttons, and 1NO+1NC auxiliary contacts. Compatible with LRD and LR2-D13 type applications, it is suitable for pumps, fans, compressors, HVAC systems and industrial control panels.
Long press to look detail
Long by picture save/share
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully

JR28 Thermal Overload Relay LRD LR2-D13 0.1A–25A

Enquiry
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully

Follow Us

Follow Us

Copyright © 2005-2025 Beijing Strong Electric Co., Ltd. All Rights Reserved.

Service Center

Please choose online customer service to communicate

Contacts
Scan a QR Code
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了