In temperature-sensitive applications such as incubators, heating chambers, or brewing systems, maintaining a precise temperature within a set range is essential. In this guide, we demonstrate how to configure the TCN5 Series Temperature Controller to work between 45°C and 50°C, using its built-in hysteresis control function.
This video tutorial showcases how to achieve:
This type of control is perfect for avoiding frequent on/off switching and maintaining system stability.
Watch how the TCN5 controller is configured to handle this logic using Hysteresis Control Mode:
III. Step-by-Step Configuration
1. Enter Parameter Setting Mode:
2. Set Control Mode to ON/OFF (PID:OFF):
3. Set the Desired Set Value (SV):
4. Set Hysteresis (oH) to 5.0°C:
5. Ensure Output is Set to Heating Mode:
Condition | Output Status |
Temp ≤ 45°C | ON (heating) |
Temp ≥ 50°C | OFF |
Temp 46–49°C | Holds last state (until next threshold) |
V. Applications
This control method is ideal for:
Please choose online customer service to communicate