Product line
Hour Meters
Choose by how the meter is fed and where it sits. The mechanical versions need no supply of their own, because the current through the load drives them; the electronic ones take a supply and count to hundredths, with an LCD or a front reset according to the letter in the code. The compact SYS and SH pair fit a small cut-out and take a wide supply; the DHC runs on its own cell on a base-mounting case; and the LCD panel meters cover the panels that are read like an instrument rather than at arm's length. Every version counts hours for maintenance intervals and controls nothing.
Looking for something else? Counters if the machine produces pieces, strokes or metres that have to be counted · Time switches if something has to switch on at a time of day rather than after a number of hours
Selection
How to choose an hour meter
Four things decide it, in this order: the body that fits the panel, the count range, the supply that is already in the machine, and how the count is read out. Everything else — quartz accuracy, sealing, temperature — follows from the body you pick.
1 · Body and cut-out
Start from the hole in the door. The HM and BZ versions use the 45 × 45 mm cut-out; the compact SYS and SH bodies hang on 44.5 × 23.6 or a 50 mm round cut-out; the 48 × 48 mm square is the smallest full-size face. Card-button cases snap in without screws, rail cases clip on the DIN rail, and the DHC and HTET bodies mount on a base or an open frame rather than a panel.
2 · Count range
A maintenance interval on a machine is read in whole hours, so five figures with a tenths wheel (0–99999.9 h) covers years of service. Where the count is a production quantity rather than running time — the 999,999 range — take a version with six figures. Sub-second accuracy only matters when the same body is used to time short cycles.
3 · Supply
Match the supply to what the panel already carries. The electrical versions take AC 220–240 V, 110 V or 24 V at 50 or 60 Hz; the wide-supply versions (DC 10–80 V / AC 100–250 V) cover the machine that runs on 24 V control and 230 V mains from the same part number, which is what keeps a single stock line. The mechanical versions need no supply at all: the current through the load drives them.
4 · Reading the count
Plain figures for a panel that is read at arm's length, an LCD where the light is poor, a reset key where the interval has to be started again from the front, and a remote reset on a flying lead where the meter sits behind a closed door. Where the machine already carries a bus, LY-758D puts the count on CAN-bus instead of a wire pair.
Selection table — every version
| Body | Model | Face / cut-out | Count range | Supply | Frequency | Reset | Mounting |
|---|---|---|---|---|---|---|---|
| HM | BZ142-1 | 72 × 72 × 36 mm | 0–99,999.99 h | AC 110 V, 220 V 50 Hz | 50 Hz | No reset | Panel, 45 × 45 cut-out |
| HM | HM-1 | 72 × 72 × 36 mm | 0–99,999.99 h | AC 110 V, 220 V 50 Hz | 50 Hz | No reset | Panel, 45 × 45 cut-out |
| HM | HM-1/uwz48 | — | 0–99999.99 h | AC 220–240 V, 110 V or 24 V, 50/60 Hz | 50/60 Hz | No reset | Card-button or DIN rail |
| HM | HM-1D | 72 × 72 × 36 mm | 0–999,999.59 h | 12–36 VDC/AC, 100–240 VAC, 380 VAC | 50/60 Hz | No reset | Panel, 45 × 45 cut-out |
| HM | HM-1R | 72 × 72 × 36 mm | 0–999,999.59 h | 12–36 VDC/AC, 100–240 VAC, 380 VAC | 50/60 Hz | Front reset | Panel, 45 × 45 cut-out |
| HM | HM-2 | 48 × 48 × 36 mm | 0–99,999.99 h | AC 110 V, 220 V 50 Hz | 50 Hz | No reset | Panel, 45 × 45 cut-out |
| HM | HM-2/uwz48 | — | 0–99999.99 h | AC 220–240 V, 110 V or 24 V, 50/60 Hz; AC/DC 10–60 V | 50/60 Hz | No reset | Card-button or DIN rail |
| HM | HM-2D | 72 × 72 × 36 mm | 0–999,999.59 h | 12–36 VDC/AC, 100–240 VAC, 380 VAC | 50/60 Hz | No reset | Panel, 45 × 45 cut-out |
| HM | HM-2R | 48 × 48 × 36 mm | 0–999,999.59 h | 12–36 VDC/AC, 100–240 VAC, 380 VAC | 50/60 Hz | Front reset | Panel, 45 × 45 cut-out |
| HM | HM-D48 | 48 × 48 × 36 mm | 0–999.59 h | 110 V, 220 V, 380 V | 50 Hz | No reset | Panel, 45 × 45 cut-out |
| SYS | SYS | — | 0–9999.9 h | DC 12–36 V / AC 150–240 V | 50/60 Hz | No reset | Panel |
| SYS | SYS-1 | 54 × 32 × 58.5 mm | 0–99,999.9 h | 10–80 VDC, 100–250 VAC | 50/60 Hz | No reset | Panel |
| SYS | SYS-1D | — | 0–99999.9 h | DC 10–60 V / AC 150–240 V | 50/60 Hz | No reset | Panel |
| SYS | SYS-1D-R | 54 × 32 × 58.5 mm | 0–999,999.59 h | 12–36 VDC/AC, 100–240 VAC, 380 VAC | 50/60 Hz | Front reset | Panel |
| SYS | SYS-2 | — | 0–99999.9 h | DC 10–80 V / AC 100–250 V | 50/60 Hz | No reset | Panel |
| SYS | SYS-3 | — | 0–99999.9 h | DC 10–80 V / AC 100–250 V | 50/60 Hz | No reset | Panel |
| SYS | SYS-3D | — | 0–99999.9 h | DC 10–60 V / AC 150–240 V | 50/60 Hz | No reset | Panel |
| SYS | SYS-4 | — | 0–99999.9 h | DC 10–80 V / AC 100–250 V | 50/60 Hz | No reset | Panel |
| SYS | SYS-5 | — | 0–99999.9 h | DC 10–80 V / AC 100–250 V | 50/60 Hz | No reset | Panel |
| SYS | SYS-N | — | 0–9999.9 h | DC 12–36 V / AC 150–240 V | 50/60 Hz | No reset | Panel |
| SYS | SYS-R | — | 0–99999.9 h | DC 12–36 V / AC 150–240 V | 50/60 Hz | No reset | Panel |
| SH | SH-1 | 59 × 59 × 55 mm | 0–99,999.9 h | 10–80 VDC, 100–250 VAC | 50/60 Hz | No reset | Panel, 50 mm round |
| SH | SH-1D | — | 0–99999.99 h | DC 10–60 V | 50/60 Hz | No reset | Panel, 50 mm round |
| SH | SH-1D2 | — | 0–99999.99 h | DC 10–60 V | 50/60 Hz | No reset | Panel, 50 mm round |
| SH | SH-2 | — | 0–99999.99 h | DC 10–80 V / AC 100–250 V | — | No reset | Panel |
| SH | SH-3 | — | 0–99999.99 h | DC 10–80 V / AC 100–250 V | — | No reset | Panel |
| LY | LY-05D1 | — | 0–99999.9 h | DC 10–60 V / AC 150–240 V | 50/60 Hz | Remote reset | Panel |
| LY | LY-05D2 | — | 0–99999.9 h | DC 10–60 V / AC 150–240 V | 50/60 Hz | Remote reset | Panel |
| LY | LY-05T | — | 0–99999.9 h | AC/DC 6–270 V | 50/60 Hz | No reset | Panel |
| LY | LY-748 | — | 0–99999.9 h | AC/DC 12–36 V / AC 100–250 V | 50/60 Hz | No reset | Panel |
| LY | LY-748D | — | 0–99999.9 h | DC 12–36 V / AC 24–250 V | 50/60 Hz | No reset | Panel |
| LY | LY-758 | — | 0–99999.9 h | AC/DC 10–80 V / AC 100–250 V | 50/60 Hz | No reset | Panel |
| LY | LY-768 | — | 0–99999.9 h | AC/DC 10–80 V / AC 100–250 V | 50/60 Hz | No reset | Panel |
| LY | LY-891 | — | 0–99999.9 h | AC 220 V, 110 V or 24 V, 50/60 Hz | 50/60 Hz | No reset | Panel |
| LY | LY-891A | — | 0–99999.9 h | AC 220 V, 110 V or 24 V, 50/60 Hz | 50/60 Hz | No reset | Panel |
| LY | LY-DH1 | — | 0–99999.9 h | DC 10–60 V / AC 150–240 V | 50/60 Hz | No reset, or reset on the body | Panel |
| TH | TH-1 | — | 99999.99 h | 10–60 V and AC 180–240 V, AC or DC | — | No reset | Panel, 50 mm bezel |
| Panel LCD | DH48L | 48 × 48 × 100 mm | 1 s–999 m 59 s, 0.1–9,999.9 h, 1–9,999 h | AC 12–380 V, DC 12–24 V | 50/60 Hz | Front keys | Panel |
| Panel LCD | H7ET | 24 × 48 × 54 mm | 99,999.9 h to 9,999 h 59 m 59 s | Own lithium cell | 50/60 Hz | Front reset | Panel |
| Panel LCD | JDM11-6L | 24 × 48 × 54 mm | 9,999,999.9 h to 9,999 h 59 m 59 s | AC 12–380 V, DC 12–24 V | 50/60 Hz | Front reset | Panel |
| Cell | DHC3L-6 | 24 × 48 × 54 mm | 99,999.9 h to 9,999 h 59 m 59 s | Own lithium cell | 50/60 Hz | Front reset | Base, two screws |
| Cell | DHC3L-8 | 24 × 48 × 54 mm | 9,999,999.9 h to 99,999 h 59 m 59 s | Own lithium cell | 50/60 Hz | Front reset | Base, two screws |
| Other | HM-2FC and HM-2FD | — | 0–99999.99 h | AC 220 V, 110 V or 24 V, 50/60 Hz; AC/DC 10–60 V | 50/60 Hz | No reset | — |
| Other | HM-4 Rail | — | 0–99999.99 h | AC 220 V, 110 V or 24 V, 50/60 Hz; AC/DC 10–60 V | 50/60 Hz | No reset | — |
| Other | HTET and HTEC | — | 0–9999 h on HTET, 0–999999 on HTEC | DC 3–24 V or AC 24–240 V | 50/60 Hz | No reset | — |
| Other | LY-758D CAN-Bus | — | 0–99999.9 h | — | 50/60 Hz | No reset | — |
Frequency follows the supply: the AC versions are 50 Hz or 60 Hz, stated per model on the page. Where a cell reads “Mechanical”, the count is driven by the load current and no supply is wired.
Filter by Specifications
Showing 47 of 47 models
Adjust filters

HM-1 Hour Meter
SE-HM-1
Six-figure mechanical counter with a tenths wheel, driven by the current through the load, so it needs no supply of its own.
View details
SYS-2 Hour Meter
SE-SYS-2
Panel case, sealed against dust and vibration. Counts 0–99999.9 h with a quartz movement; supply DC 10–80 V / AC 100–250 V.
View details
LY-891A Hour Meter
SE-LY-891A
Panel case with no reset key: the figure stays where it is, so the meter reads the whole life of the machine rather than the last interval. The…
View details
SH-2 Hour Meter
SE-SH-2
Square case with a quartz movement and a five-figure counter. Counts running hours with a quartz movement; supply DC 10–80 V / AC 100–250 V.
View details
HM-2 Hour Meter
SE-HM-2
The same mechanical movement in the smaller case, for a cut-out that is already in the door.
View details
SYS-3 Hour Meter
SE-SYS-3
Panel case with a bezel clip. Counts 0–99999.9 h with a quartz movement; supply DC 10–80 V / AC 100–250 V.
View details
LY-891 Hour Meter
SE-LY-891
Panel case with no reset key, so the count cannot be cleared from the front and the total always reads the life of the machine.
View details
SH-3 Hour Meter
SE-SH-3
Square case, deeper body, same quartz movement. Counts running hours with a quartz movement; supply DC 10–80 V / AC 100–250 V.
View details
HM-1R Hour Meter
SE-HM-1R
Electronic hour meter with a reset button on the front, so a service interval can be started again from the panel.
View details
SYS-4 Hour Meter
SE-SYS-4
Round case with the quartz movement. Counts 0–99999.9 h with a quartz movement; supply DC 10–80 V / AC 100–250 V.
View details
SH-1D Hour Meter
SE-SH-1D
Round case with the hour band and indicator lamps on the face. Counts running hours with a quartz movement; supply DC 10–60 V.
View details
HM-2FC and HM-2FD Hour Meters
SE-HM-2FC
Card-button case that snaps into the panel cut-out. Counts running hours with a quartz movement; supply AC 220 V, 110 V or 24 V, 50/60 Hz; AC/DC…
View details
HM-2R Hour Meter
SE-HM-2R
The reset version in the smaller case, with the button on the front.
View details
SYS-5 Hour Meter
SE-SYS-5
Round case, two fixing screws. Counts 0–99999.9 h with a quartz movement; supply DC 10–80 V / AC 100–250 V.
View details
SH-1D2 Hour Meter
SE-SH-1D2
Round case, the second body in the SH-1D pair. Counts running hours with a quartz movement; supply DC 10–60 V.
View details
HM-4 Rail Hour Meter
SE-HM-4
Guide-rail case that clips on the DIN rail. Counts running hours with a quartz movement; supply AC 220 V, 110 V or 24 V, 50/60 Hz; AC/DC 10–60 V.
View details
HM-1D Hour Meter
SE-HM-1D
Electronic hour meter with an LCD that counts hundredths, for the intervals that are measured in minutes rather than days.
View details
SYS Hour Meter
SE-SYS
Square mechanical case. Counts 0–9999.9 h with a quartz movement; supply DC 12–36 V / AC 150–240 V.
View details
HM-2/uwz48 Hour Meter
SE-HM-2-2
Snap or rail mounted case with a five-figure counter. Counts running hours with a quartz movement; supply AC 220–240 V, 110 V or 24 V, 50/60 Hz;…
View details
HM-2D Hour Meter
SE-HM-2D
The LCD version in the smaller case, same movement and same cut-out.
View details
SYS-N Hour Meter
SE-SYS-N
Square case, narrow bezel. Counts 0–9999.9 h with a quartz movement; supply DC 12–36 V / AC 150–240 V.
View details
HM-1/uwz48 Hour Meter
SE-HM-1-2
Snap-type or rail-type case, five figures. Counts running hours with a quartz movement; supply AC 220–240 V, 110 V or 24 V, 50/60 Hz.
View details
LY-758D CAN-Bus Hour Meter
SE-LY-758D
The hour meter that talks: instead of a wire per machine, the count goes out on the vehicle bus as an extended CAN frame, so a controller reads the…
View details
HM-D48 Hour Meter
SE-D48
A mechanical counter on a base-mounting case, for the machines that are counted from the side rather than the front.
View details
SYS-R Hour Meter
SE-SYS-R
Round case in the SYS family. Counts 0–99999.9 h with a quartz movement; supply DC 12–36 V / AC 150–240 V.
View details
HTET and HTEC Hour Meters
SE-HTET-HTEC
Open-frame module with a liquid-crystal display. Counts running hours with a quartz movement; supply DC 3–24 V or AC 24–240 V.
View details
BZ142-1 Hour Meter
SE-BZ142-1
Mechanical totaliser with a terminal cover, in a case that takes the wires from below.
View details
SYS-1D Hour Meter
SE-SYS-1D-2
Panel case, the LCD version. Counts 0–99999.9 h with a quartz movement; supply DC 10–60 V / AC 150–240 V.
View details
SYS-1 Hour Meter
SE-SYS-1
Compact sealed meter in a rectangular case that takes a wide supply, AC or DC, on the same unit.
View details
SYS-3D Hour Meter
SE-SYS-3D
Panel case, the later LCD version. Counts 0–99999.9 h with a quartz movement; supply DC 10–60 V / AC 150–240 V.
View details
SYS-1D-R Hour Meter
SE-SYS-1D
The compact body with an LCD and a front reset, for the panels that are read and reset in service.
View details
LY-05T Hour Meter
SE-LY-05T
Round case on the widest supply in the range. Counts 0–99999.9 h with a quartz movement; supply AC/DC 6–270 V.
View details
SH-1 Hour Meter
SE-SH-1
Square compact meter with a wide supply, for the cut-out a pressure gauge would use.
View details
LY-DH1 Hour Meter
SE-DH1
Panel case, reset on the body. Counts 0–99999.9 h with a quartz movement; supply DC 10–60 V / AC 150–240 V.
View details
DHC3L-6 Hour Meter
SE-DHC3L-6
Base-mounting counter with its own lithium cell, so no supply is wired at all.
View details
LY-05D1 Hour Meter
SE-LY-05D1
Panel case with a remote reset on a flying lead. Counts 0–99999.9 h with a quartz movement; supply DC 10–60 V / AC 150–240 V.
View details
DHC3L-8 Hour Meter
SE-DHC3L-8
The same base-mounting body with the larger display, for a panel read at a step back.
View details
LY-05D2 Hour Meter
SE-LY-05D2
Panel case with a remote reset, second body. Counts 0–99999.9 h with a quartz movement; supply DC 10–60 V / AC 150–240 V.
View details
H7ET Hour Meter
SE-H7ET
LCD panel meter on its own cell, for the places where a wire is inconvenient.
View details
TH-1 Hour Meter
SE-TH-1
50 mm bezel, four-figure quartz movement. Counts 99999.99 h with a quartz movement; supply 10–60 V and AC 180–240 V, AC or DC.
View details
JDM11-6L Hour Meter
SE-JDM11-6L
LCD panel meter that takes a wide AC or DC supply on the same unit.
View details
LY-748 Hour Meter
SE-LY-748
Panel case, wide AC or DC supply. Counts 0–99999.9 h with a quartz movement; supply AC/DC 12–36 V / AC 100–250 V.
View details
DH48L Hour Meter
SE-DH48L
Digital unit with four time bases and a memory that holds its figure without power, for the intervals that are timed rather than run.
View details
LY-748D Hour Meter
SE-LY-748D
Panel case, higher accuracy movement. Counts 0–99999.9 h with a quartz movement; supply DC 12–36 V / AC 24–250 V.
View details
LY-758 Hour Meter
SE-LY-758
Panel case, wide supply. Counts 0–99999.9 h with a quartz movement; supply AC/DC 10–80 V / AC 100–250 V.
View details
LY-768 Hour Meter
SE-LY-768
Panel case, wide supply, larger bezel. Counts 0–99999.9 h with a quartz movement; supply AC/DC 10–80 V / AC 100–250 V.
View details
Industrial Hour Meter
SE-H01
A counter with nothing to set: the scale is printed on the face and the only connections are the two supply leads. It is built for plant, marine and…
View detailsThese parts, in a machine
The same parts are specified differently from one machine to the next. These pages show the set to order, the faults that follow and the part numbers that go with them.
Other product lines
Need help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.
