Control and protection for lifts, hoists and crane panels

A lifting panel is judged by what it refuses to do: it must not close on a lost phase, must not run a hoist on two phases, and must not let a limit switch failure turn into a runaway. The parts that refuse are the ones worth buying.

The four parts of a lifting panel

1 · Protect the supply

Phase-failure and voltage relays drop the main contactor on loss, reversal or an out-of-window supply — before the brake releases.

SE-XJ3-G

2 · Switch the motor

Reversing contactors for hoist and travel, mechanically interlocked; the same frame carries the brake rectifier feed.

SE-CJX2-F

3 · Hold the speed

A VFD for soft start and stop, which is what stops the load swinging on a travelling crane and takes the shock out of the gearbox.

SE-VFD-H350

4 · Count and time

Hours on the hoist motor for the service interval, and a delay on the brake release so the motor is at torque before the load is free.

SE-SYS-2

What to order, by equipment

EquipmentProtectionSwitchingDrive / metering
Electric hoist, 0.5–5 tXJ3-G phase relayCJX2-F reversing pairSYS-2 hour meter
Overhead travelling crane, 2-speedXJ3-G + thermal overloadCJX2-F + limit switch feedH350 VFD on long travel
Small goods liftXJ3-G + door interlock circuitCJX2 main + reversingH350 VFD, SYS-2 for service hours

The hour meter is the cheapest safety item on a hoist: the brake and the rope are replaced on hours, and a hoist with no meter is maintained on opinion.

What goes wrong on site

The hoist hums and will not lift
One phase missing, or a contactor pole welded. The XJ3-G should have dropped the main — if it did not, check that it is wired ahead of the coil, not after it.
The brake releases before the motor has torque
No delay on the brake feed. The load drops a few centimetres every start, which is the symptom that wears the rope.
Reversing contactors weld after a while
Plugging without a zero-speed or delay interlock. Add the delay, not a bigger contactor.
Crane travel jerks at start
Direct-on-line starting on a long travel drive. A VFD with an S-curve removes the swing and the gearbox shock.