Control and protection for lifts, hoists and crane panels
A lifting panel is judged by what it refuses to do: it must not close on a lost phase, must not run a hoist on two phases, and must not let a limit switch failure turn into a runaway. The parts that refuse are the ones worth buying.
The four parts of a lifting panel
1 · Protect the supply
Phase-failure and voltage relays drop the main contactor on loss, reversal or an out-of-window supply — before the brake releases.
SE-XJ3-G2 · Switch the motor
Reversing contactors for hoist and travel, mechanically interlocked; the same frame carries the brake rectifier feed.
SE-CJX2-F3 · Hold the speed
A VFD for soft start and stop, which is what stops the load swinging on a travelling crane and takes the shock out of the gearbox.
SE-VFD-H3504 · Count and time
Hours on the hoist motor for the service interval, and a delay on the brake release so the motor is at torque before the load is free.
SE-SYS-2What to order, by equipment
| Equipment | Protection | Switching | Drive / metering |
|---|---|---|---|
| Electric hoist, 0.5–5 t | XJ3-G phase relay | CJX2-F reversing pair | SYS-2 hour meter |
| Overhead travelling crane, 2-speed | XJ3-G + thermal overload | CJX2-F + limit switch feed | H350 VFD on long travel |
| Small goods lift | XJ3-G + door interlock circuit | CJX2 main + reversing | H350 VFD, SYS-2 for service hours |
The hour meter is the cheapest safety item on a hoist: the brake and the rope are replaced on hours, and a hoist with no meter is maintained on opinion.
What goes wrong on site
- The hoist hums and will not lift
- One phase missing, or a contactor pole welded. The XJ3-G should have dropped the main — if it did not, check that it is wired ahead of the coil, not after it.
- The brake releases before the motor has torque
- No delay on the brake feed. The load drops a few centimetres every start, which is the symptom that wears the rope.
- Reversing contactors weld after a while
- Plugging without a zero-speed or delay interlock. Add the delay, not a bigger contactor.
- Crane travel jerks at start
- Direct-on-line starting on a long travel drive. A VFD with an S-curve removes the swing and the gearbox shock.