Industry · web handling

Temperature, tension and length on textile, printing and drying lines

On a stenter or a printing line the product never stops moving, so the control has to work while the web runs: the heater modulates rather than switches, the length counter follows the roller, and the drive holds the speed.

What a running web needs

1 · Modulate

A thyristor unit on the heater modulates the power continuously, which is what keeps a stenter zone flat instead of cycling between two temperatures.

SE-BDTY

2 · Control

A PID controller with a 4–20 mA output drives the thyristor; the same family covers the drying cans and the hot-air zone.

SE-TC4

3 · Measure

A rotary encoder or a measuring wheel gives the length; the counter totals metres per roll so the batch matches the order.

SE-LY-11J

4 · Drive

A VFD holds the line speed and the draw between sections, which is where the register on a printing line is won or lost.

SE-VFD-H350

What to order, by line

LineHeatingControlMeasurement
Stenter, 6–10 zonesBDTY thyristor per zoneTC4 with 4–20 mA outputEncoder + LY-11J length counter
Printing line with dryerBSTY three-phase thyristorTC4 per dryer zoneEncoder + line-speed display
Coating / laminatingBDTY single phaseTC4 + TC5 in the same panelMeasuring wheel counter

Length is the number the customer argues about: a roll measured 2 % short is a claim. A measuring-wheel counter with a 10-year memory settles the argument at the end of the shift.

What goes wrong on site

Zone temperature swings 5 °C and the fabric shades
An SSR switching a large heater. Move to a thyristor unit with phase-angle control, or split the zone into two smaller heaters.
The length counter reads short on long runs
Wheel slip. Check the wheel pressure on the web and the 1:3 ratio setting before recalibrating.
Register drifts across the web
Draw between sections, not temperature. Check the VFD speed loop and the dancer or load cell.
Heater fails open on one zone and the alarm never shows
No current monitoring. A thyristor unit with a current limit or a simple current relay makes the failure visible.

Related reading

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.