Multi-zone temperature control for injection moulding and extrusion
Barrel zones, hot runner tips and mould cooling all fail differently. The controller, the switching element and the probe have to be matched per zone, not bought as one part number for the whole machine.
The four parts of a temperature zone
1 · Probe
Spring-loaded or bolt-on probes for the barrel, thin-tip probes for hot runner nozzles. A loose probe reads the air gap, not the melt.
SE-TC-M122 · Controller
One controller per zone, or a multi-channel unit where the panel space is tight. TC5 for the reading at arm's length, TC4 where three output types have to be selectable.
SE-TC53 · Switching
SSR for barrel zones up to 3 kW; thyristor units where the zone is large or the current must be limited softly. Zero-cross keeps the noise off the instrument supply.
SE-SSR-DA4 · Count and time
Shot counters and cycle timers give the batch record: how many shots, how long the cycle ran, when the mould was last changed.
SE-JDM11-6H-CWhat to order, by machine
| Machine | Probes | Controller | Switching | Metering |
|---|---|---|---|---|
| Small injection machine, 4–6 zones | K-type bolt-on, 1 per zone | TC4, SSR drive output | SSR-DA 25 A + HS-SSR, 1 per zone | |
| Hot runner, 8–16 tips | Thin-tip K probes | TC5, 4–20 mA output | SSR-DA 10–25 A, one per tip | |
| Extruder barrel, 5–7 zones, 9–30 kW total | Spring-loaded M12 probes | TC4, 4–20 mA output | BDTY / BSTY thyristor unit |
The metering column is where most panels are short: a shot counter and a cycle timer turn a temperature log into a production record. Add JDM11-6H-C for the count and H3CR-A for the cycle if the machine has no PLC.
What goes wrong on a moulding machine
- One zone reads several degrees low and the heater stays on
- A probe that has backed out of its well reads the barrel wall instead of the melt. Check the spring pressure and the probe depth before touching the controller.
- Hot runner tips read unstable at start-up
- Thin-tip probes have almost no thermal mass. Autotune with the mould at working temperature, and keep the tip probe isolated from the manifold block.
- The SSR fails every few months on the same zone
- Usually a heat sink that is too small or a panel without airflow. Size the sink for the current plus 30 %, and mount it vertically.
- Cycle time drifts through the shift
- A cycle timer records it. Without one, the drift is invisible until the parts show it, which is why the H3CR-A earns its place on the panel.