Motor Protection & Voltage Relays
Choose by what can go wrong. The phase failure relays (XJ3, APR) drop the contactor when a phase is missing or the sequence reverses; the voltage protectors (AVP, JVM) hold the contactor closed only while the supply is inside the window; and the current protectors (MK, MKC) cover the motors that have no overload relay of their own.
Filter by Specifications
Showing 20 of 20 models
Adjust filters

XJ3-G Phase Failure Relay
SE-XJ3-G
The plain phase relay: it drops the contactor when a phase goes missing and refuses to let it pull in on the wrong sequence. The C version watches…
View details
XJ3-D Voltage Protector
SE-XJ3-D
The full-protection version: over-voltage, under-voltage, a missing phase and a reversed sequence all drop the contactor, and both time delays are…
View details
RST25 Phase Sequence Relay
SE-RST25
Sequence only, in a body narrow enough to sit beside the contactor: one normally open contact, closed while the phases are in order.
View details
JVM-1 Voltage Monitor
SE-JVM-1
The monitor version of the sequence relay: a taller case with room for the terminals, one normally open contact, and the same 3 A rating as the rest…
View details
JVM-2 Voltage Monitor
SE-JVM-2
The same monitor with the terminal layout the older panels were drilled for.
View details
TRD-N Star-Delta Timer
SE-TRD-N
The delay that covers the start: it holds through the inrush, releases when the motor is up to speed, and resets in a third of a second so a restart…
View details
AMD-N Speed Detector
SE-AMD-N
The relay that watches rotation rather than current: four time ranges cover a slow pump shaft up to a fast fan, and the contact drops when the pulses…
View details
TWB-ND Reversing Relay
SE-TWB-ND
The interlock in a box: ask for reverse and it waits for the forward contactor to drop before it moves, which is what keeps a motor from being…
View details
MK-05 Motor Protector
SE-MK-05
It reads the current through a core and drops the contactor when the reading falls outside the window, with the sensitivity set between five and…
View details
MKC-06 Over-Voltage Protector
SE-MKC-06
A two-module cut-out that opens when the supply climbs: rated for the usual three-phase systems, with an eight amp contact and a normally open output…
View details
AVP-63A Voltage Protector
SE-AVP-63A
The protector with the current loop as well as the voltage window: over-current, under-voltage and over-voltage are each set on the face, and the…
View details
AVP-01 Voltage Protector
SE-AVP-01
The member of the family with a switch beside the display: the same over-current, under-voltage and over-voltage settings, on a face that can be…
View details
AVP-02 Voltage Protector
SE-AVP-02
The version with the three-digit display, so the voltage and the current can be read without a meter.
View details
SZ-3LVA Three-Phase Voltage Protector
SE-SZ-3LVA
The three-phase member: three rows of digits show what each phase is doing, and the same current and voltage settings decide when the load is dropped.
View details
PU-NC Sensor Power Supply
SE-PU-NC
The supply that keeps a sensor alive in a panel with no low-voltage rail: it takes the mains, feeds the head from a stabilised output, and switches a…
View details
C-6 Sensor Controller
SE-C-6
The amplifier half of a sensing pair. It feeds the head from its own supply terminals, takes the return on the input, and switches a relay that a PLC…
View details
JGZ1 Brake Solid State Relay
SE-JGZ1
The brake supply in one block: alternating current in, direct current out, and no contacts to wear, so a brake that is applied every cycle does not…
View details
SS-22 Speed Controller
SE-SS-22
A controller for the small motors: six watts up to two hundred and fifty, mounted either way round so the knob can face the operator whichever side…
View details
APR-3 / APR-4 Phase Relays
SE-APR-3
One family, three duties. Every version reads the three phases on its own, so it works whatever the load current is, and keeps the contactor coil…
View details
AG4Q-K Latching Relay
SE-AG4Q-K
The memory relay: a pulse sets it and the contact stays put when the coil is dead, so a start command survives a supply dip and a two-position…
View detailsThese parts, in a machine
The same parts are specified differently from one machine to the next. These pages show the set to order, the faults that follow and the part numbers that go with them.
Other product lines
Need help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.