Industry · rubber
Temperature control for presses, autoclaves and vulcanising lines
Vulcanising is a time-at-temperature process: the cure is decided by how long the rubber sits at the set point, so a press that overshoots on the first cycle scraps the batch, not just the cycle.
The four parts of a vulcanising loop
1 · Sense
A Pt100 in the platen and a second probe in the steam or oil line, so a heating fault is visible before the product is.
SE-TC-WRNK2362 · Control
PID with a ramp-soak profile: the platen has to arrive at temperature slowly enough that the surface and the core cure together.
SE-TC43 · Switch
A thyristor unit on the heaters, because a press zone is large and switching it on and off shortens element life.
SE-BDTY4 · Time
A cure timer that only starts when the platen is in band, which is what makes the cure time mean something.
SE-H3CR-AWhat to order, by equipment
| Equipment | Sensing | Control | Switching |
|---|---|---|---|
| Hydraulic press, 2–4 platens | Pt100 in each platen | TC4 per platen, ramp-soak | BDTY thyristor + CJX2 |
| Autoclave / vulcanising oven | 2 × Pt100, chamber and load | TC5 + H3CR-A cure timer | BSTY three-phase thyristor |
| Continuous vulcanising line | Pt100 per zone | TC4 per zone + LY-11J length counter | BDTY per zone |
The cure timer is the quality record: a batch that cured for 12 minutes at 150 °C can be proved, and a batch that cured 'about right' cannot.
What goes wrong on site
- The first cycle of the shift overshoots and the batch is scrapped
- Cold platen and a controller tuned hot. Use ramp-soak so the platen arrives slowly, and tune at working temperature.
- Cure time varies between operators
- The timer is started by hand. Wire it to the in-band relay so it can only start when the platen is actually at temperature.
- Heaters fail every few months
- Contactors switching a large resistive load. Move to a thyristor unit and the element life roughly doubles.
- Platen temperature is uneven across the face
- One probe reads the average of one spot. Fit two probes and control on the hotter one.
Related reading
Need help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.