Industry · packaging

Temperature, time and count for packaging machines

A sealing bar, a shrink tunnel and a labelling head each need a different loop: heat held at the jaw, a dwell time that repeats, and a count of what went through. The three usually come from three suppliers — they do not have to.

Three loops on one machine

1 · Heat

Jaw and tunnel temperature: a TC4 with SSR drive output holds the set point, a K-type probe sits in the bar where the film actually touches.

SE-TC4

2 · Dwell

The seal time repeats to a tenth of a second on an H3CR-A, which also gives the machine a delay-on and interval mode without a PLC.

SE-H3CR-A

3 · Count

Bags, boxes or pouches: a JDM9-4 counts up to a preset and closes a relay, which is what stops the line at the batch figure.

SE-JDM9-4

4 · Guard

Where an operator loads by hand, a light curtain stops the sealing head without a mechanical guard in the way of the film path.

SE-GM

What to order, by machine

MachineHeat controlTimingCountingExtras
Band sealer / continuous sealerTC4 + K probe + SSR-DA 25 AH3CR-A dwell timer—HS-SSR heat sink
Shrink tunnelTC5 + 2 × K probes + SSR-DA 40 AH3Y-2 delay on start—VFD for the conveyor belt
VFFS / pouch lineTC4 + SSR-DA + HS-SSRH3CR-A + H3Y-2JDM9-4 preset counterLight curtain at the load station

For a line that runs several film widths, the counter pays for itself in the first week: it stops the line at the batch figure instead of letting the operator count cartons by hand.

What goes wrong on a packaging line

Seals are weak at the start of a run and fine later
The jaw is cold. Either the controller is set to a slow start or the SSR is undersized and the bar takes too long to recover between cycles.
Dwell time drifts by a few tenths of a second
A mechanical timer will always drift. Replace it with an H3CR-A on the same base and the repeatability is in the timer, not in the operator's hand.
The counter miscounts when two products pass together
A photoelectric sensor counts edges; two touching items read as one. Set the sensor back, or count at the sealing jaw where the film separates them.
The machine stops for no reason mid-batch
Check the preset counter first: a counter wired to the stop relay will end the run at the figure, and that is working as intended.

Related reading

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.