Product line
AC Contactors
Choose by the current and by what the panel has to do with it. The LC2-D frame covers nine to a hundred and seventy amps in three or four poles; CJX2N adds a one NO and one NC auxiliary on the board; the F frames take the same job up to eight hundred amps, in three pole, four pole and mechanically interlocked pairs. Around them sit the versions a site asks for: the LC2-Z for direct current, the LC2-N reversing pair, the CJ19 for capacitor banks, the LC6K miniature body, the JKC1 in module width, the CJ20 open frame up to six hundred and thirty amps, and the LE1-D starter that arrives with contactor and relay already wired in a sealed box. Every one of them takes the LR-D thermal relay and the LA auxiliary, delay and interlock blocks that are listed with it.
Filter by Specifications
Showing 16 of 16 models
Adjust filters
Standard AC Contactors (9A–800A)
General-purpose 3-pole and 4-pole AC contactors (LC2-D, CJX2N, F-frame) for motor and resistive load switching from 9A up to 800A.

JZC4 Contactor Relay
SE-JZC4
The contactor body used as a relay, for the control circuits that need more contacts than the main contactor carries. Ten amps thermal and six amps…
View details
CJX2N AC Contactor
SE-CJX2N
The contactor with the auxiliary set already built in, so a panel that needs one NO and one NC contact does not have to buy the block. Nine to…
View details
CJX2-F Three Pole Contactor
SE-CJX2-F-2
The large F frame in three poles, for the circuits that carry a whole machine rather than a motor: a hundred and fifteen to three hundred and thirty…
View details
CJX2-F Four Pole Contactor
SE-CJX2-F-3
The same large F frame with four main contacts, for the supplies where the neutral breaks with the phases or where a second load rides on the same…
View details
CJX2 AC Contactor
SE-CJX2
A contactor is the mechanical answer to the same job a solid state relay does: switch a heater or a motor from a control signal. CJX2 covers the…
View details
LC2-D AC Contactor
SE-LC2-D
The general-purpose contactor for motor starting and load switching: three or four poles, nine amps in AC-3 at 380–440 volts up to a hundred and…
View detailsReversing, DC & Capacitor-Duty Contactors
Mechanically interlocked reversing pairs (LC2-N), DC coil/load contactors (LC2-Z), capacitor-bank contactors (CJ19) and open-frame units (CJ20).

LC2-Z DC Contactor
SE-LC2-Z
A contactor built for direct current: the arc does not cross zero on a DC circuit, so the chamber and the throw are made for it. Nine to ninety-five…
View details
LC2-N Reversing Contactor
SE-LC2-N
The reversing pair: two contactors on a common base with a mechanical interlock between them, so forward and reverse can never close together. Nine…
View details
CJ19 Capacitor Contactor
SE-CJ19
Made for capacitors rather than motors: the damping device is inside the case, so the closing surge is held to twenty times the rated current and the…
View details
CJX2-F Reversing Contactor
SE-CJX2-F
The large F frames built as a reversing pair: two contactors side by side with the interlocking bar across them, so a forward command cannot meet a…
View details
CJ20 AC Contactor
SE-CJ20
The open-frame contactor, the one that shows its arc chutes: ten to six hundred and thirty amps, up to six hundred and sixty volts, and a coil wound…
View detailsMiniature, Modular & Enclosed Starters
Compact LC6K miniature contactors, JKC1 modular DIN-rail contactors and pre-wired LE1-D enclosed motor starters.

LC6K Mini Contactor
SE-LC6K
The miniature body for the boxes where a standard contactor will not fit: six to sixteen amps in AC-3, a DC coil that stays silent when it pulls in,…
View details
LE1-D Magnetic Starter
SE-LE1-D
The contactor and the thermal relay already wired into one sealed box, with the start and stop buttons on the lid. Nine to ninety-five amps, IP65…
View details
JKC1 Modular Contactor
SE-JKC1
The contactor that lines up with the breakers: two to twelve modules of nine millimetres, twenty-five to a hundred amps in AC-7a, and a coil wound…
View detailsThermal Relays & Auxiliary Blocks
LR-D thermal overload relays and LA auxiliary, time-delay and mechanical interlock blocks matched to our AC contactor frames.

Auxiliary Contacts and Delay Heads
SE-AUXILIARY-CONTAC
Everything that clips onto the contactor: front blocks from one NO up to four NC, a side block where the front is already full, air delay heads that…
View details
LR-D Thermal Overload Relay
SE-LR-D
A contactor switches the motor; the thermal relay is what stops it cooking when the load jams. The LR-D range runs from a tenth of an amp to…
View detailsThese parts, in a machine
The same parts are specified differently from one machine to the next. These pages show the set to order, the faults that follow and the part numbers that go with them.
Other product lines
Need help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.