Food equipment is judged on repeatability: the same bake, the same fry, the same batch. That puts the sensor and the controller in the middle of the product quality, not at the edge of it.
What a baking or frying loop needs
1 · Sense
A Pt100 or K-type probe in the chamber, plus a second probe on the product side where the bake has to be proven. Stainless sheaths, food-grade cable.
SE-TC-SS2 · Control
PID with a clear dual display so the operator reads set point and actual from the door. TC5 for the bright white LED, TC4 where the output type has to be selectable.
SE-TC53 · Switch
SSR with a heat sink for the element bank, or a three-phase thyristor unit on a tunnel oven where the load is measured in tens of kilowatts.
SE-SSR-DA4 · Time and count
Bake time on an H3CR-A, batch count on a JDM9 preset counter, so a shift ends at the figure the packing line expects.
SE-H3CR-AWhat to order, by equipment
| Equipment | Sensing | Control | Switching |
|---|---|---|---|
| Deck oven, 2–6 kW per deck | K-type, 6 mm sheath | TC4 + SSR-DA 25 A | HS-SSR heat sink |
| Convection oven / proofing cabinet | Pt100 in the chamber | TC5 + SSR-DA 40 A | HS-SSR, fan interlock |
| Continuous fryer / tunnel oven | 2 × K-type, product and chamber | TC5 with 4–20 mA output | BSTY three-phase thyristor unit |
For export to the EU or North America, quote the CE or UL version at the same time: the certification decides the market, and the controller is the part that carries the mark.
What goes wrong on site
- Bakes drift through the day and recover overnight
- A probe coated with carbon reads the crust, not the air. Clean or replace the probe before touching the tuning.
- The element bank cycles too hard and the contactor welds
- An SSR that fails closed, or a contactor sized on average current instead of inrush. Check the failed part before replacing it.
- The display reads fine but the product is undercooked
- The probe sits in a corner where the airflow is different from the product zone. Move the probe to the working zone.
- Temperature overshoots on start-up by 30 °C
- Autotune empty. A loaded oven has a different thermal mass; tune it with a typical load inside.