Safety Light Curtains
SCL Safety Light Curtain Grating
Fine-pitch safety light grating at five and ten millimetre spacing, close enough that a finger cannot pass: a point-of-operation guard, not a cell guard.

- Output
- NPN or PNP, or relay NO / NC on order
- Beam pitch
- 5, 10, 20 or 40 mm optical axis spacing
- Protected height
- 60 mm to 2000 mm
- Supply
- DC 24 V with a 20 % window
Technical specifications
| Product | Fine-pitch safety light grating, emitter and receiver pair |
|---|---|
| Beam pitch | 5, 10, 20 or 40 mm optical axis spacing |
| Protected height | 60 mm to 2000 mm |
| Output | NPN or PNP, or relay NO / NC on order |
| Supply | DC 24 V with a 20 % window |
| Response | under 10 ms |
| Section | 35 mm by 27 mm aluminium bar |
Product overview
Part no. SE-SCL-GRATINGindustry model SCL-GRATING
Also known as: SCL safety light curtain
The fine grid: five and ten millimetre spacing, close enough that a finger cannot pass between two beams. That is what makes it a point-of-operation guard rather than a cell guard — the machine has to stop before a hand reaches the tooling, and only a fine pitch gives the time.
Key features
- The face, the setting and the response of this version, listed in its own table
- One version per page, because these differ between them
- Photograph and drawing where the factory has supplied one
Works with
The parts that go into the same panel and are usually ordered with it.
Fits
- A point of operation a finger could reach
- A press, a small benchtop machine, a fine tooling station
- Where the stop has to happen before the hand arrives
Not for
- Cell or perimeter guarding, where the coarse pitch is enough
- A frame that cannot hold two bars parallel
Technical data
The fine pitch grating: five and ten millimetre spacing, which is what tells a finger from a hand. The protected height is the same range as the rest of the family, but the beam count climbs much higher because the beams sit closer together.
- Protection height
- 60–2000 mm (conventional)
- Beam pitch
- 5 / 10 / 20 / 40 mm
- Resolving power
- 10 / 15 / 25 / 45 mm
- Number of optical axes
- 4, 6, 8, 10 …
- Working voltage
- DC 24 V ± 20 %
- Output method
- NPN or PNP (conventional) · relay NO · relay NC
- Output current
- ≤ 200 mA
- Response time
- < 10 ms
- Protection distance
- 0.1–20 m
- Power
- < 5 W
- Section size
- 35 × 27 mm
- Enclosure protection
- IP65
- Working temperature
- −10 to +55 °C
- Working humidity
- < 85 % RH at 20 °C
- Insulation resistance
- ≥ 100 MΩ
- Dielectric strength
- AC 1500 V, 60 s
- Ambient light immunity
- 10 000 lux (incidence angle > 5°)
Protection height and model codes
Four spacings on one page, because a finger-protection job and a body-protection job are often the same machine. Pick the spacing by what has to be kept out, then the beam count by the height of the opening.
5 mm spacing, 10 mm resolution
| Beams | Protected height | Housing length | Model |
|---|---|---|---|
| 16 | 75 mm | 154 mm | SCL-16-10N |
| 24 | 115 mm | 194 mm | SCL-24-10N |
| 32 | 155 mm | 234 mm | SCL-32-10N |
| 40 | 195 mm | 274 mm | SCL-40-10N |
| 48 | 235 mm | 314 mm | SCL-48-10N |
| 56 | 275 mm | 354 mm | SCL-56-10N |
| 64 | 315 mm | 394 mm | SCL-64-10N |
| 72 | 355 mm | 434 mm | SCL-72-10N |
| 80 | 395 mm | 474 mm | SCL-80-10N |
| 88 | 435 mm | 514 mm | SCL-88-10N |
| 96 | 475 mm | 554 mm | SCL-96-10N |
| 104 | 515 mm | 594 mm | SCL-104-10N |
| 112 | 555 mm | 634 mm | SCL-112-10N |
| 120 | 595 mm | 674 mm | SCL-120-10N |
| 128 | 635 mm | 714 mm | SCL-128-10N |
10 mm spacing, 15 mm resolution
| Beams | Protected height | Housing length | Model |
|---|---|---|---|
| 8 | 70 mm | 114 mm | SCL-08-15N |
| 12 | 110 mm | 179 mm | SCL-12-15N |
| 16 | 150 mm | 219 mm | SCL-16-15N |
| 20 | 190 mm | 259 mm | SCL-20-15N |
| 24 | 230 mm | 299 mm | SCL-24-15N |
| 28 | 270 mm | 339 mm | SCL-28-15N |
| 32 | 310 mm | 379 mm | SCL-32-15N |
| 36 | 350 mm | 419 mm | SCL-36-15N |
| 40 | 390 mm | 459 mm | SCL-40-15N |
| 44 | 430 mm | 499 mm | SCL-44-15N |
| 48 | 470 mm | 539 mm | SCL-48-15N |
| 52 | 510 mm | 579 mm | SCL-52-15N |
| 56 | 550 mm | 619 mm | SCL-56-15N |
| 60 | 590 mm | 659 mm | SCL-60-15N |
| 64 | 630 mm | 699 mm | SCL-64-15N |
20 mm spacing
| Beams | Protected height | Housing length | Model |
|---|---|---|---|
| 4 | 60 mm | 114 mm | SCL-04-20N |
| 6 | 100 mm | 179 mm | SCL-06-20N |
| 8 | 140 mm | 219 mm | SCL-08-20N |
| 10 | 180 mm | 259 mm | SCL-10-20N |
| 12 | 220 mm | 299 mm | SCL-12-20N |
| 14 | 260 mm | 339 mm | SCL-14-20N |
| 16 | 300 mm | 379 mm | SCL-16-20N |
| 18 | 340 mm | 419 mm | SCL-18-20N |
| 20 | 380 mm | 459 mm | SCL-20-20N |
| 22 | 420 mm | 499 mm | SCL-22-20N |
| 24 | 460 mm | 539 mm | SCL-24-20N |
| 26 | 500 mm | 579 mm | SCL-26-20N |
| 28 | 540 mm | 619 mm | SCL-28-20N |
| 30 | 580 mm | 659 mm | SCL-30-20N |
| 32 | 620 mm | 699 mm | SCL-32-20N |
40 mm spacing
| Beams | Protected height | Housing length | Model |
|---|---|---|---|
| 4 | 120 mm | 199 mm | SCL-04-40N |
| 6 | 200 mm | 279 mm | SCL-06-40N |
| 8 | 280 mm | 359 mm | SCL-08-40N |
| 10 | 360 mm | 439 mm | SCL-10-40N |
| 12 | 440 mm | 519 mm | SCL-12-40N |
| 14 | 520 mm | 599 mm | SCL-14-40N |
| 16 | 600 mm | 679 mm | SCL-16-40N |
| 18 | 680 mm | 759 mm | SCL-18-40N |
| 20 | 760 mm | 839 mm | SCL-20-40N |
| 22 | 840 mm | 919 mm | SCL-22-40N |
| 24 | 920 mm | 999 mm | SCL-24-40N |
| 26 | 1000 mm | 1079 mm | SCL-26-40N |
| 28 | 1080 mm | 1159 mm | SCL-28-40N |
| 30 | 1160 mm | 1239 mm | SCL-30-40N |
| 32 | 1240 mm | 1319 mm | SCL-32-40N |
How the code reads
Series, beam count, then the number that fixes the pitch. On the twenty and forty millimetre models that number is the spacing itself; on the fine-pitch models it is the resolution class the grating is built to, ten for the five millimetre grating and fifteen for the ten.
1SCL-232-320-4N
- 1
SCL series
- 2
Beam count
- 3
Spacing, or resolution class on the fine grids
- 4
Output: N = NPN, P = PNP
Finger protection or body protection
The spacing is the whole decision. A five millimetre grid will not let a finger through, so it guards a point of operation where a hand could reach the tooling. Twenty and forty millimetre spacings are for keeping a body out of a cell, where stopping for an arm is early enough.
- Wire the outputs to a safety relay, not straight to the contactor coil
- Check the resolution against the reach distance the machine allows, not against the gap alone
- The fine grids need the bars parallel within a millimetre or the near beams false-trip
- Cover the whole opening: a grid that stops short leaves a way round it
Brackets
A side bracket comes with the pair, and the two cantilever versions stand the bars clear of a deep frame.
| Side mounting bracket | Included with the pair |
| Cantilever bracket | Optional |
| Integral cantilever bracket | Optional |
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All Safety Light Curtains
GM Safety Light Curtain
SE-GM
A light curtain is the guard that lets the work through. An emitter bar and a receiver bar stand either side of the opening, and the machine stops…
View details
SCF Rugged Safety Light Curtain
SE-SCF
The SCF is the same idea as the GM curtain built for harder rooms: a thicker section, a fixed 24V supply and a response twice as fast, for a cell…
View details
SCE Waterproof Safety Light Curtain
SE-SCE
A light curtain for the rooms that get hosed down. The SCE puts the same optics inside a capped aluminium tube rated for directed water, so the guard…
View details
SCB Front Ultra-Thin Safety Light Curtain
SE-SCB
The bar for openings a standard curtain cannot enter. At 13.5 mm deep the SCB sits against the machine face instead of standing off it, so a small…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.