AC Contactors

CJX2 AC Contactor

CJX2 AC contactor for circuits up to 690V and up to 95A, with auxiliary contact blocks, pneumatic time-delay heads and surge suppressors.

CJX2-1210 AC contactor, front view with terminal markings
CJX2-1210: main contacts 1, 3, 5 in and 2, 4, 6 out, coil at A1 and A2.
Rated current
up to 95A
Rated voltage
up to 690V
Frequency
50 or 60Hz
Standards
GB 14048.5, IEC 60947-5-1
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

ProductAC contactor for remote switching and motor starting
Rated voltageup to 690V
Rated currentup to 95A
Frequency50 or 60Hz
StandardsGB 14048.5, IEC 60947-5-1
Accessoriesfront auxiliary block F4, pneumatic time-delay head F5, side auxiliary block NCF1, surge suppressor SR2

Product overview

Part no. SE-CJX2

Also known as: Chint CJX2 · CJX2 contactor · CJX2 AC contactor

A contactor is the mechanical answer to the same job a solid state relay does: switch a heater or a motor from a control signal. CJX2 covers the usual panel range, up to 95A at 690V, and pairs with a thermal overload relay to make a starter that trips on overload rather than sitting there cooking a motor.

Key features

  • Rated voltage up to 690V, rated current up to 95A
  • Remote making and breaking, and frequent motor starting
  • Combines with a thermal overload relay to form a starter
  • Contact arrangement chosen in the last two digits of the code
  • Front and side auxiliary contact blocks
  • Pneumatic time-delay heads, on-delay or off-delay
  • Surge suppressors in two current classes
  • GB 14048.5, IEC 60947-5-1

Works with

The parts that go into the same panel and are usually ordered with it.

Ratings & model code (09A–95A)

AC contactors up to 690V and 95A (50/60Hz) per GB 14048.5 / IEC 60947-5-1. Mounts by screw or 35mm DIN rail across the range (75mm rail from 40A up).

CJSeries

AC contactor family

XFrame

Compact frame (09A–95A)

2Design

2nd generation frame

09–95AC-3 current

Rated A at 380V AC-3

10 / 01 / 11Contacts

10=1NO, 01=1NC (≤32A); 11=1NO+1NC (≥40A); 04=4NO; 08=2NO+2NC

Parameter-09-12-18-25-32-40-50-65-80-95
Rated operating current (A)
380V AC-39121825324050658095
380V AC-43.557.78.51218.524283744
660V AC-36.68.91218213439424949
Thermal Ith (A)2025324050607080110125
3-phase motor AC-3 (kW)
220V2.2345.57.5111518.52225
380V45.57.5111518.522303745
660V5.57.59111518.530333745
Life & coil
Electrical AC-3 (×10⁴)1001001001001008080606060
Mechanical (×10⁴)1000100010001000100010001000100010001000
Coil inrush / hold (VA)70/970/970/9.570/9.5110/14110/14200/57200/57200/57200/57

Coil pull-in: 85–110% Us; release: 20–75% Us. Aux contacts: AC-15 360VA, DC-13 33W, 10A thermal. Example order: CJX2-0910, coil 220V 50Hz (M5), 10 pcs + F4-22, 5 pcs.

Technical references & accessories

Show coil voltage codes (24V–600V · 50Hz / 60Hz / 50–60Hz)
V24364248110127220230240380400415440480600
50HzB5C5D5E5F5G5M5P5U5Q5V5N5R5T5X5
60HzB6C6D6E6F6G6M6P6U6Q6V6N6R6T6X6
50/60HzB7C7D7E7F7G7M7P7U7Q7V7N7R7T7X7
Show dimensions & mounting hole patterns (09A–95A)
ModelA (W)B (H)C (D)D (+F4)E (+F5)a × bØ
CJX2-09 – 12477682120.5140.534/35 × 50/604.5
CJX2-18477687125.5145.534/35 × 50/604.5
CJX2-25578695133.5153.540 × 484.5
CJX2-325786100138.5158.540 × 484.5
CJX2-4011 – 651177129116154.5174.540 × 1056.5
CJX2-4004 – 650884129116–127154.5174.540 × 1056.5
CJX2-8011 – 951187129127165.5185.540 × 1056.5
CJX2-8004 – 950896129122–135160.5180.540 × 1056.5
Show electrical life curve (09A–95A)
CJX2 electrical life curves
Show accessories (F4 / F5 / NCF1 / SR2) & derived assemblies

Accessories

F4-20 / 11 / 02
2NO · 1NO+1NC · 2NC (top mount)
F4-40 / 31 / 22 / 13 / 04
4-pole top-mount auxiliary blocks
NCF1-11C
1NO+1NC side-mounted block
F5-T0 / T2 / T4
On-delay pneumatic head (0.1–3s · 0.1–30s · 10–180s)
F5-D0 / D2 / D4
Off-delay pneumatic head (0.1–3s · 0.1–30s · 10–180s)
SR2-A / SR2-B
Coil surge suppressor (A: 09–32A · B: 40–95A)

Derived assemblies

Delayed contactor
Contactor + F5 pneumatic head
Reversing contactor
2 contactors + mechanical interlock
Magnetic starter
Contactor + thermal overload relay
Capacitor contactor
Contactor + current-limiting block
Star-delta starter
3 contactors + F5 delay + F4 aux

Supply & OEM

Available with your logoMOQ 20 units·Lead time on quotation·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related models

All AC Contactors

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.