Safety Light Curtains
SCT Universal Safety Light Curtain
Universal safety light curtain in a 29 by 26 mm bar, relay or transistor output on the same unit, across the full range of protected heights.

- Output
- NPN or PNP, or relay NO / NC on order
- Beam pitch
- 20 mm or 40 mm optical axis spacing
- Protected height
- 60 mm to 2000 mm
- Supply
- DC 24 V with a 20 % window
Technical specifications
| Product | Universal safety light curtain, emitter and receiver pair |
|---|---|
| Beam pitch | 20 mm or 40 mm optical axis spacing |
| Protected height | 60 mm to 2000 mm |
| Output | NPN or PNP, or relay NO / NC on order |
| Supply | DC 24 V with a 20 % window |
| Response | under 10 ms |
| Section | 29 mm by 26 mm aluminium bar |
Product overview
Part no. SE-SCT
Also known as: SCT universal safety light curtain
The curtain to reach for first. A 29 by 26 mm bar, relay or transistor output on the same unit and the full range of protected heights, for the machine whose guarding question is the ordinary one: keep the operator out of the opening and let the work through.
Key features
- The face, the setting and the response of this version, listed in its own table
- One version per page, because these differ between them
- Photograph and drawing where the factory has supplied one
Works with
The parts that go into the same panel and are usually ordered with it.
Fits
- An ordinary machine opening on a dry workshop floor
- Either a contactor panel or a PLC input, on the same unit
- Hand or body protection at either spacing
Not for
- A line that gets washed down — take the SCE
- A point of operation a finger can reach — take the SCL
Technical data
The conventional output curtain: a 29 by 26 mm bar with relay or transistor output, for the great majority of machines where the guarding question is a straightforward one. It is the model to start from, and to leave behind only when the opening, the wash-down or the reach distance makes one of the others necessary.
- Protection height
- 60–2000 mm (conventional)
- Beam pitch
- 5 / 10 / 20 / 40 mm
- Resolving power
- 10 / 15 / 25 / 45 mm
- Number of optical axes
- 4, 6, 8, 10 …
- Working voltage
- DC 24 V ± 20 %
- Output method
- NPN or PNP (conventional) · relay NO · relay NC
- Output current
- ≤ 200 mA
- Response time
- < 10 ms
- Protection distance
- 0.1–20 m
- Power
- < 5 W
- Section size
- 29 × 26 mm
- Enclosure protection
- IP65
- Working temperature
- −10 to +55 °C
- Working humidity
- < 85 % RH at 20 °C
- Insulation resistance
- ≥ 100 MΩ
- Dielectric strength
- AC 1500 V, 60 s
- Ambient light immunity
- 10 000 lux (incidence angle > 5°)
Protection height and model codes
Same two spacings. The bar runs about 46 mm longer than the protected span, so a 620 mm opening takes the 686 mm bar, and the brackets have to clear the bar rather than the protected height.
20 mm optical axis spacing
| Beams | Protected height | Housing length | Model |
|---|---|---|---|
| 4 | 60 mm | 126 mm | SCT-0420N |
| 6 | 100 mm | 166 mm | SCT-0620N |
| 8 | 140 mm | 206 mm | SCT-0820N |
| 10 | 180 mm | 246 mm | SCT-1020N |
| 12 | 220 mm | 286 mm | SCT-1220N |
| 14 | 260 mm | 326 mm | SCT-1420N |
| 16 | 300 mm | 366 mm | SCT-1620N |
| 18 | 340 mm | 406 mm | SCT-1820N |
| 20 | 380 mm | 446 mm | SCT-2020N |
| 22 | 420 mm | 486 mm | SCT-2220N |
| 24 | 460 mm | 526 mm | SCT-2420N |
| 26 | 500 mm | 566 mm | SCT-2620N |
| 28 | 540 mm | 606 mm | SCT-2820N |
| 30 | 580 mm | 646 mm | SCT-3020N |
| 32 | 620 mm | 686 mm | SCT-3220N |
| 34 | 660 mm | 726 mm | SCT-3420N |
| 36 | 700 mm | 766 mm | SCT-3620N |
| 38 | 740 mm | 806 mm | SCT-3820N |
| 40 | 780 mm | 846 mm | SCT-4020N |
| 42 | 820 mm | 886 mm | SCT-4220N |
| 44 | 860 mm | 926 mm | SCT-4420N |
| 100 | 1980 mm | 2046 mm | SCT-10020N |
40 mm optical axis spacing
| Beams | Protected height | Housing length | Model |
|---|---|---|---|
| 4 | 120 mm | 206 mm | SCT-0440N |
| 6 | 200 mm | 286 mm | SCT-0640N |
| 8 | 280 mm | 366 mm | SCT-0840N |
| 10 | 360 mm | 446 mm | SCT-1040N |
| 12 | 440 mm | 526 mm | SCT-1240N |
| 14 | 520 mm | 606 mm | SCT-1440N |
| 16 | 600 mm | 686 mm | SCT-1640N |
| 18 | 680 mm | 766 mm | SCT-1840N |
| 20 | 760 mm | 846 mm | SCT-2040N |
| 22 | 840 mm | 926 mm | SCT-2240N |
| 24 | 920 mm | 1006 mm | SCT-2440N |
| 26 | 1000 mm | 1086 mm | SCT-2640N |
| 28 | 1080 mm | 1166 mm | SCT-2840N |
| 30 | 1160 mm | 1246 mm | SCT-3040N |
| 32 | 1240 mm | 1326 mm | SCT-3240N |
| 34 | 1320 mm | 1406 mm | SCT-3440N |
| 36 | 1400 mm | 1486 mm | SCT-3640N |
| 38 | 1480 mm | 1566 mm | SCT-3840N |
| 40 | 1560 mm | 1646 mm | SCT-4040N |
| 42 | 1640 mm | 1726 mm | SCT-4240N |
| 44 | 1720 mm | 1806 mm | SCT-4440N |
| 50 | 1960 mm | 2046 mm | SCT-5040N |
How the code reads
Series, beam count, spacing, then the output. The N in the tables is the NPN version; the PNP version carries a P, and the relay NO and NC versions are named on the order rather than in the code.
1SCT-232-320-4N
- 1
SCT series
- 2
Beam count
- 3
Optical axis spacing, mm
- 4
Output: N = NPN, P = PNP
Why start here
Most openings do not need a special housing. Three things decide whether this one is enough.
- A square 35 × 35 mm bar with the window in one face, for a straight run across a doorway, a chute or a conveyor mouth
- Detection, signalling and interlocks: it triggers a warning or a stop, it does not replace a certified safety circuit
- The same response and output choices as the rest of the range, so it wires into the same relay
Brackets
Same three fittings as the rest of the range: the side bracket in the box, and two cantilever versions for when the bars have to stand clear of a deep frame.
| Side mounting bracket | Included with the pair |
| Cantilever bracket | Optional |
| Integral cantilever bracket | Optional |
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All Safety Light Curtains
GM Safety Light Curtain
SE-GM
A light curtain is the guard that lets the work through. An emitter bar and a receiver bar stand either side of the opening, and the machine stops…
View details
SCB Front Ultra-Thin Safety Light Curtain
SE-SCB
The bar for openings a standard curtain cannot enter. At 13.5 mm deep the SCB sits against the machine face instead of standing off it, so a small…
View details
SCC Side Slim Safety Light Grid
SE-SCC
A grid rather than a curtain: the bars run down the sides of the aperture and the beams cross it, so the guard works where the face of the opening is…
View details
SCF Rugged Safety Light Curtain
SE-SCF
The SCF is the same idea as the GM curtain built for harder rooms: a thicker section, a fixed 24V supply and a response twice as fast, for a cell…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.