Variable Frequency Drives

H350 Series Variable Frequency Drive (VFD)

Variable frequency drives from 0.4kW to 15kW with V/F control with multi-step speed, analogue 0–10V and 4–20mA reference, in single-phase 220V and three-phase 380V input versions.

H350 series compact variable frequency drive, front view
H350 compact VFD with the VCD BOP-3 operator, 115 x 150 x 150 mm on the 0.75 kW to 3 kW versions.
Output
three-phase 220VAC or 380VAC, matched to the input configuration
Input
single-phase 220VAC, 50/60Hz
Power range
0.4kW to 15kW
Input (380V builds)
three-phase 380VAC, 50/60Hz
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

ProductVariable frequency drive for three-phase motor speed control
Power range0.4kW to 15kW
Inputsingle-phase 220VAC, 50/60Hz
Input (380V builds)three-phase 380VAC, 50/60Hz
Outputthree-phase 220VAC or 380VAC, matched to the input configuration
ControlV/F control with multi-step speed, analogue 0–10V and 4–20mA reference
Protectionover-current, over-voltage, under-voltage, over-heat and short circuit
Coolingfan-cooled, panel or wall mounting
ApplicationsFans, pumps, conveyors, mixers and machine tool spindles
350 0.4 kW0.4 kW, single phase 220–240 V · 2.1 A · 1.0 kg
350 0.75 kW0.75 kW, single phase 220–240 V · 4 A · 1.0 kg
350 1.5 kW1.5 kW, single phase 220–240 V · 7 A · 1.1 kg
350 2.2 kW2.2 kW, single phase 220–240 V · 9.5 A · 1.1 kg
350 3.0 kW3.0 kW, single phase 220–240 V · 11 A · 1.15 kg
350 0.75 kW 3800.75 kW, three phase 380–440 V · 2.5 A · 1.0 kg
350 1.5 kW 3801.5 kW, three phase 380–440 V · 4.1 A · 1.1 kg
350 2.2 kW 3802.2 kW, three phase 380–440 V · 5.8 A · 1.15 kg
350 3.0 kW 3803.0 kW, three phase 380–440 V · 7.9 A · 1.2 kg
350 4.0 kW4.0 kW, three phase 220–240 V · 9.4 A · 2.3 kg
350 5.5 kW5.5 kW, three phase 220–240 V · 12.6 A · 2.35 kg
350 7.5 kW7.5 kW, three phase 220–240 V · 16.1 A · 2.35 kg

Product overview

Part no. SE-VFD-H350industry model VFD-H350

Also known as: H350 VFD · H350 frequency inverter · H350 variador de frecuencia

The H350 series takes a fixed supply and gives a three-phase motor a variable one, so speed follows the process instead of the mains. Three input configurations cover the usual panel arrangements: single-phase 220V to three-phase 220V, three-phase 380V to three-phase 380V, and single-phase 220V to three-phase 380V. Power runs from 0.4kW to 15kW.

Key features

  • Power range from 0.4kW to 15kW
  • Single-phase 220V input, three-phase 220V output
  • Three-phase 380V input, three-phase 380V output
  • Single-phase 220V input stepped up to three-phase 380V
  • Analogue 0–10V and 4–20mA speed reference
  • Multi-step speed and panel keypad control
  • Over-current, over-voltage, over-heat and short-circuit protection
  • Fan-cooled, panel or wall mounting

Works with

The parts that go into the same panel and are usually ordered with it.

Panel and keys

Five controls on the faceplate: value up and value down, the set key, the start and stop keys, and the speed knob in the middle. The display is four digits above the digital operator marking.

Front panel of the H350 compact drive
Front panel of the H350 compact drive

Dimensions, weights and output current

The cabinet is sized from three of these columns: the overall size for the space, the packing size for the shipping carton, and the gross weight for the freight quote. Output current is what the motor actually sees.

H350 outline: 115mm wide, 150mm long and 150mm deep on the 0.75kW to 3kW versions
H350 outline: 115mm wide, 150mm long and 150mm deep on the 0.75kW to 3kW versions

Single-phase 220V in, three-phase 220V out

VersionOutput currentOverall (mm)Packing (mm)NetGross
H350-0D4-S2G2.1A150 × 115 × 130173 × 135 × 1721.0kg1.2kg
H350-0D75-S2G4A150 × 115 × 130173 × 135 × 1721.1kg1.3kg
H350-1D5-S2G7A150 × 115 × 150173 × 135 × 1721.1kg1.3kg
H350-2D2-S2G9.5A150 × 115 × 150173 × 135 × 1721.1kg1.3kg
H350-3D0-S2G11A150 × 115 × 150173 × 135 × 1721.15kg1.35kg

Three-phase 380V in, three-phase 380V out

VersionOutput currentOverall (mm)Packing (mm)NetGross
H350-0D75-T4G2.5A150 × 115 × 130173 × 135 × 1721.1kg1.3kg
H350-1D5-T4G4.1A150 × 115 × 150173 × 135 × 1721.1kg1.3kg
H350-2D2-T4G5.8A150 × 115 × 150173 × 135 × 1721.15kg1.35kg
H350-3D0-T4G7.9A150 × 115 × 150173 × 135 × 1721.2kg1.4kg
H350-3D7-T4G9.4A210 × 118 × 180265 × 175 × 2322.3kg2.55kg
H350-5D5-T4G12.6A210 × 118 × 180265 × 175 × 2322.35kg2.6kg
H350-7D5-T4G16.1A210 × 118 × 180265 × 175 × 2322.35kg2.6kg

Terminals and what each one does

Two blocks, and the split matters: R, S, T take the supply and U, V, W drive the motor, so the two must never be swapped. Everything on the lower strip is control-level, referenced to COM for the digital inputs and to GND for the analogue ones.

Wiring diagram
Main circuit and control circuit on one sheet: 220V takes R and S, 380V takes R, S and T, the braking resistor sits across P and B, and U, V, W carry the motor. The control side is COM with S1 to S5, GND with AVI and ACI, and the relay contacts RA, RB and RC.

Main circuit

TerminalFunctionNote
R · S · TSupply input380V versions use all three; 220V versions use R and S or R and T, as the terminal label shows.
U · V · WMotor outputKeep the cable under 50m to hold leakage current down. Never put a contactor or a capacitor on this side.
P · BBraking resistorAcross P and B, to the value in the table below.
PEEarthMust be connected; the drive is not isolated from the supply.

Control circuit

TerminalFunctionNote
COMDigital commonZero potential for S1 to S5.
S1Digital input 1Factory set to forward run (F2.13).
S2Digital input 2Factory set to reverse (F2.14).
S3Digital input 3Factory set to multi-speed step 1 (F2.15).
S4Digital input 4Factory set to multi-speed step 2 (F2.16).
S5Digital input 5Factory set to external reset (F2.17).
GNDAnalogue commonZero potential for AVI and ACI.
AVI0–10V inputSpeed reference, input resistance above 50kΩ.
10VReference supply+10V for a potentiometer, 10mA maximum.
ACI4–20mA inputSpeed reference, 100Ω input resistance.
A0Analogue outputWhat it reports is set by F2.10.
RA · RB · RCRelay outputContact rating AC 250V/3A, DC 24V/2A; function set by F2.20.

Braking resistor

Where the load has to stop quickly or is overhauled, a resistor goes across P and B. The value is set by the drive, not chosen freely: too low draws too much current through the brake switch, too high does nothing.

VersionResistor powerResistance
0.75kW 220V100W200Ω
1.5kW 220V300W100Ω
2.2kW 220V300W100Ω
3.0kW 220V500W100Ω
4.0kW 220V500W75Ω
5.5kW 220V1000W75Ω
0.75kW 380V100W750Ω
1.5kW 380V300W400Ω
2.2kW 380V300W250Ω
3.0kW 380V300W250Ω
4.0kW 380V500W150Ω
5.5kW 380V800W100Ω
7.5kW 380V1000W75Ω

Supply & OEM

Available with your logoMOQ 5 units·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related guides

Need help selecting the right model?