Temperature Controllers

KT49-5-01-2-A — KT49 with voltage pulse for an external ssr

The 48 × 96 mm (1/8 DIN) LCD controller with SSR drive output and Pt100 input.

KT temperature controller, 48×48×64, 48×96×64, 72×72×64 and 96×96×64 mm, thermocouple K, E, J, S, R, B, N or T…
KT: 48×48×64, 48×96×64, 72×72×64 and 96×96×64 mm; thermocouple K, E, J, S, R, B, N or T on the 1 versions, Pt100 or Cu50 on the 2 versions; relay contact 250 V AC 3 A, or SSR drive.
Output
Voltage pulse for an external SSR
Bezel
48 × 96
Panel cut-out
45 × 92
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesKT series LCD temperature controller
ModelsKT48 / KT49 / KT72 / KT96
Panel sizes48×48×64, 48×96×64, 72×72×64 and 96×96×64 mm
Panel cutouts45×45, 45×92, 68×68 and 92×92 mm
Range0–1370 °C
Supply100–240 VAC
Inputthermocouple K, E, J, S, R, B, N or T on the 1 versions, Pt100 or Cu50 on the 2 versions
Main outputrelay contact 250 V AC 3 A, or SSR drive
ControlPID, with the alarm set as an upper or a lower deviation
Response timeone second
Front protectionIP44
Mountingpanelled, 64 mm case behind every front

Product overview

Part no. SE-KT

Also known as: KT temperature controller · KT PID controller

An LCD controller in four bezels, all with a 64 mm case depth. Each size ships as a relay version or an SSR drive, with a thermocouple input that takes the whole range of types or an RTD input, and one alarm set as an upper or a lower deviation.

Ordering code

KT49-5-01-2-A

The 48 × 96 mm (1/8 DIN) LCD controller with SSR drive output and Pt100 input.

Order codeKT49-5-01-2-A
Bezel (mm)48 × 96
Cut-out (mm)45 × 92
OutputVoltage pulse for an external SSR
Output terminalsper the case diagram
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: Drives an external solid state relay, so the load current is the relay's rating

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Reading this order code

How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.

PositionReadsMeaning
①4948 × 96 mm (1/8 DIN) bezel on a 45 × 92mm cut-out
②5Voltage pulse for an external SSR
③2RTD input, Pt100 or Cu50
—01Body generation, fixed on current stock
④AOne alarm, set as an upper deviation; B is the lower-deviation version
Output terminals: per the case diagram·Drives an external solid state relay, so the load current is the relay's rating

Key features

  • The face, the setting and the response of this version, listed in its own table
  • One version per page, because these differ between them
  • Photograph and drawing where the factory has supplied one

Works with

The parts that go into the same panel and are usually ordered with it.

Ordering & Selection Guide

Four positions after KT: panel size (all share a 64mm body depth), output, input, and alarm letter. Series digits 01 are fixed.

KT48①4②01 1③A④

① · Panel size (64mm depth)

48
48×48mm · cut-out 45×45
49
48×96mm · cut-out 45×92
72
72×72mm · cut-out 68×68
96
96×96mm · cut-out 92×92

② · Output

4
Relay contact output (RELAY)
5
Voltage pulse output (SSR)

③ · Input

1
Thermocouple — K, E, J, S, R, B, N or T
2
RTD — Pt100 or Cu50

④ · Alarm

A
Upper deviation alarm
B
Lower deviation alarm

Worked example

KT48-4-01-1-A

KT48-4-01-1-A: 48×48 mm bezel (①=48), relay output (②=4), series 01 fixed, thermocouple input (③=1) and upper-deviation alarm (④=A). Set ③ to 2 for RTD, or ② to 5 for the voltage-pulse output that drives an external SSR.

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

Wiring

The whole range on one sheet, body by body: a contactor arrangement, a solid state relay arrangement and an alarm light for each, with the electrician's schematic and the terminal reference beside them. The circuit is the same idea throughout; the numbers belong to the case, so read the panel that matches yours.

KT series · wiring, schematics and terminal references

KT series · wiring, schematics and terminal references

The jumper changes with the build and is the part to check before powering up: 2–4 on the contactor build, 2–9 on the alarm build, and none on the SSR build, where the output pair is a 12 VDC drive. The sensor keeps its colours on every body — red to the signal terminal, blue to its pair.

Download the sheet (PDF)

Documents for this family

All documents

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What panel size and cut-out does the KT need?

48×48×64, 48×96×64, 72×72×64 and 96×96×64 mm. The cut-out is 45×45, 45×92, 68×68 and 92×92 mm

Which sensors can the KT read?

thermocouple K, E, J, S, R, B, N or T on the 1 versions, Pt100 or Cu50 on the 2 versions

What output options does the KT have?

relay contact 250 V AC 3 A, or SSR drive

What supply voltage does the KT need?

100–240 VAC

What is the temperature range?

0–1370 °C

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.