AC Contactors
CJX2-F Reversing Contactor
The F frames built as a reversing pair: two contactors and an interlocking bar, from a hundred and fifteen to eight hundred amps.

- Dimensions
- Overall and mounting dimensions per model are listed on the sample sheet, a × b × b1 × c × G × G1 × J × L × P1 in millimetres
- Use
- Reversible starting of three-phase motors, with the interlock bar between the two contactors
- Mounting
- Panel, with the fixing bar across the pair
- CJX2-F115N dimensions
- a 345, b 162, b1 137, c 171, G 80, G1 71, J 57, L 107, P1 77
Technical specifications
| Series | CJX2-F reversing contactor, mechanically interlocked |
|---|---|
| Use | Reversible starting of three-phase motors, with the interlock bar between the two contactors |
| Accessories | One-pole main contact block, three and four pole reversing power connectors, vertical and horizontal interlockers, interlocking fixing bar |
| Mounting | Panel, with the fixing bar across the pair |
| CJX2-F115N | 115 A at 400 V · 30 kW at 220/230 V · 55 kW at 380/400 V · 59 kW at 415 V · 59 kW at 440 V · 75 kW at 500 V · 80 kW at 660/690 V · 65 kW at 1000 V |
| CJX2-F150N | 150 A at 400 V · 40 kW at 220/230 V · 45 kW at 380/400 V · 80 kW at 415 V · 80 kW at 440 V · 90 kW at 500 V · 100 kW at 660/690 V · 65 kW at 1000 V |
| CJX2-F185N | 185 A at 400 V · 63 kW at 220/230 V · 90 kW at 380/400 V · 100 kW at 415 V · 100 kW at 440 V · 110 kW at 500 V · 110 kW at 660/690 V · 100 kW at 1000 V |
| CJX2-F225N | 225 A at 400 V · 75 kW at 220/230 V · 110 kW at 380/400 V · 110 kW at 415 V · 110 kW at 440 V · 129 kW at 500 V · 129 kW at 660/690 V · 100 kW at 1000 V |
| CJX2-F265N | 265 A at 400 V · 100 kW at 220/230 V · 132 kW at 380/400 V · 140 kW at 415 V · 140 kW at 440 V · 160 kW at 500 V · 160 kW at 660/690 V · 147 kW at 1000 V |
| CJX2-F330N | 330 A at 400 V · 110 kW at 220/230 V · 160 kW at 380/400 V · 180 kW at 415 V · 200 kW at 440 V · 200 kW at 500 V · 220 kW at 660/690 V · 160 kW at 1000 V |
| CJX2-F400N | 400 A at 400 V · 147 kW at 220/230 V · 200 kW at 380/400 V · 220 kW at 415 V · 250 kW at 440 V · 257 kW at 500 V · 280 kW at 660/690 V · 185 kW at 1000 V |
| CJX2-F500N | 500 A at 400 V · 200 kW at 220/230 V · 250 kW at 380/400 V · 280 kW at 415 V · 295 kW at 440 V · 355 kW at 500 V · 355 kW at 660/690 V · 335 kW at 1000 V |
| CJX2-F630N | 630 A at 400 V · 220 kW at 220/230 V · 335 kW at 380/400 V · 375 kW at 415 V · 400 kW at 440 V · 400 kW at 500 V · 450 kW at 660/690 V · 425 kW at 1000 V |
| CJX2-F800N | 800 A at 400 V · 220 kW at 220/230 V · 450 kW at 380/400 V · 425 kW at 415 V · 425 kW at 440 V · 450 kW at 500 V · 475 kW at 660/690 V · 450 kW at 1000 V |
| Dimensions | Overall and mounting dimensions per model are listed on the sample sheet, a × b × b1 × c × G × G1 × J × L × P1 in millimetres |
| CJX2-F115N dimensions | a 345, b 162, b1 137, c 171, G 80, G1 71, J 57, L 107, P1 77 |
| CJX2-F150N dimensions | a 345, b 170, b1 137, c 171, G 80, G1 71, J 57, L 107, P1 71 |
| CJX2-F185N dimensions | a 357, b 174, b1 137, c 181, G 80, G1 78, J 59.5, L 113.5, P1 78 |
| CJX2-F225N dimensions | a 357, b 197, b1 137, c 181, G 80, G1 78, J 59.5, L 113.5, P1 62 |
| CJX2-F265N dimensions | a 425, b 203, b1 145, c 213, G 96, G1 109, J 61.5, L 141, P1 100 |
| CJX2-F330N dimensions | a 447, b 206, b1 145, c 219, G 96, G1 124, J 65.5, L 145, P1 107 |
| CJX2-F400N dimensions | a 446, b 206, b1 209, c 219, G 80, G1 170, G2 157, J 64.5, J2 67, L 145, P1 107 |
| CJX2-F500N dimensions | a 485, b 238, b1 209, c 232, G 80, G1 170, G2 156, J 84.5, J2 66, L 146, P1 112 |
| CJX2-F630N dimensions | a 636, b 304, b1 280, c 255, G 180, G1 139, G2 68.5, J 155, P1 137 |
| CJX2-F800N dimensions | a 636, b 304, b1 280, c 255, G 180, G1 139, G2 68.5, J 155, P1 137 |
Product overview
Part no. SE-CJX2-F
Also known as: Chint CJX2-F · CJX2-F contactor · CJX2-F AC contactor
The large F frames built as a reversing pair: two contactors side by side with the interlocking bar across them, so a forward command cannot meet a reverse one. One hundred and fifteen amps up to eight hundred, with the power connectors and the one-pole block available to match.
Key features
- 115 A to 800 A reversing pairs
- Interlocking bar across the pair
- Power connectors and one-pole block to match
Works with
The parts that go into the same panel and are usually ordered with it.
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All AC Contactors
CJX2 AC Contactor
SE-CJX2
A contactor is the mechanical answer to the same job a solid state relay does: switch a heater or a motor from a control signal. CJX2 covers the…
View details
CJX2-F Three Pole Contactor
SE-CJX2-F-2
The large F frame in three poles, for the circuits that carry a whole machine rather than a motor: a hundred and fifteen to three hundred and thirty…
View details
CJX2-F Four Pole Contactor
SE-CJX2-F-3
The same large F frame with four main contacts, for the supplies where the neutral breaks with the phases or where a second load rides on the same…
View details
CJX2N AC Contactor
SE-CJX2N
The contactor with the auxiliary set already built in, so a panel that needs one NO and one NC contact does not have to buy the block. Nine to…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.