Temperature Controllers

CHB402FK02-M*AN — CHB402 with built-in electromechanical relay

The version to order when the controller only has to close a contactor coil, or a small heater under 3A.

CHB902, CHB402 and CHB702 PID temperature controllers
CHB902, CHB402 and CHB702: the same body in three bezels.
Output
Built-in electromechanical relay, 250VAC 3A, dry contact
Bezel
48 × 96
Panel cut-out
45 × 92
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesCHB series PID temperature controller
ModelsCHB401 / CHB402 / CHB702 / CHB902
Panel sizes48×48×82, 48×96×75, 72×72×73 and 96×96×66 mm
Panel cutouts45×45, 45×92, 68×68 and 92×92 mm
Supply220 VAC, 50/60 Hz, with a 380 V build
Accuracy±0.5% or ±1.0% FS
ControlPID with autotuning, and on/off with an adjustable differential
InputK, E, J, S, R, B, N and T thermocouples, plus Pt100 and Cu50
Outputtwo outputs on one instrument: a relay contact and an SSR drive
Alarmfull-range setting
Operating environment0–50 °C, 30–85% RH, no corrosive gas

Product overview

Part no. SE-CHB

Also known as: CHB temperature controller · CHB PID controller

The CHB is the CH body built with both outputs fitted: a relay contact and an SSR drive on the same instrument, so a machine that heats through a contactor and a solid state relay does not need two controllers. Ten input types, PID with autotuning, and a full-range alarm setting.

Ordering code

CHB402FK02-M*AN

The version to order when the controller only has to close a contactor coil, or a small heater under 3A.

Order codeCHB402FK02-M*AN
Bezel (mm)48 × 96
Cut-out (mm)45 × 92
OutputBuilt-in electromechanical relay, 250VAC 3A, dry contact
Output terminalson the case diagram
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: Switches a contactor coil or a heater up to 3A directly; anything larger needs a contactor or an SSR

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Reading this order code

How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.

PositionReadsMeaning
1CHB40248 × 96 mm (1/8 DIN) bezel on a 45 × 92mm panel cut-out
2FControl mode: reverse acting, the usual choice for heating
3K02Input: K thermocouple over 0–400 °C; other letters select J, E, N, T, R, S, B, Pt100 or Cu50
4MBuilt-in electromechanical relay, 250VAC 3A, dry contact
5*ANAlarm pair: A is an upper deviation alarm, N leaves the second alarm off; N-24VDC or N-24VAC would set a low-voltage supply instead
Output terminals: on the case diagram·Switches a contactor coil or a heater up to 3A directly; anything larger needs a contactor or an SSR

Key features

  • CHB401 / CHB402 / CHB702 / CHB902
  • Panel cutouts 45×45, 45×92, 68×68 and 92×92 mm
  • K, E, J, S, R, B, N and T thermocouples, plus Pt100 and Cu50, selectable on the unit
  • two outputs on one instrument: a relay contact and an SSR drive
  • ±0.5% or ±1.0% FS accuracy, 220 VAC, 50/60 Hz, with a 380 V build supply

Works with

The parts that go into the same panel and are usually ordered with it.

Ordering & Selection Guide

Six positions after CHB, the same six the CH series uses: the panel size, the control action, the input and its range, the main output, then one letter for each alarm. The prefix is what tells the two apart at the counter.

CHB702①F②K02③−M④A⑤B⑥

① · Panel size (mm)

40148×48×82, cut-out 45×45
40248×96×75, cut-out 45×92
70272×72×73, cut-out 68×68
90296×96×66, cut-out 92×92

② · Control action

FPID, reverse action — heating
DPID, direct action — cooling

③ · Input type and range

K02K thermocouple
E02E thermocouple
D10Pt100 RTD
P10Cu50 RTD

④ · Main output

MRelay contact (RELAY)
VVoltage pulse (SSR drive)
8Current output 4–20 mA

⑤⑥ · First and second alarm

NNo alarm configured
AUpper deviation
BLower deviation
CUpper and lower deviation
DDeviation band
EUpper deviation, hold action
FLower deviation, hold action
GUpper and lower deviation, hold action
HProcess high (absolute)
JProcess low (absolute)
KProcess high, hold action
LProcess low, hold action

Worked example

CHB702FK02-MAB

72×72×73 on a 68×68 cut-out, reverse action for heating, K thermocouple input, relay as the main output, and the two alarms set to upper and lower deviation.

What this series is built as

Every CHB leaves the factory with two outputs on the same instrument, a relay contact and an SSR drive. Which one drives the heater is set in the parameters; both are wired to their own terminals, so a machine can heat through a contactor and switch a solid state relay from the same device.

Panel and keys

PV is the measured value, red and uppermost; SV is the set point, green and beneath it. The dot row under the display names what the instrument is doing: OUT while the main output is on, AT while auto-tuning runs, AL1 and AL2 when either alarm has tripped. Four keys below trim the set point and walk the parameter list.

CHB702 front panel: PV measured temperature value in red digits, SV temperature set point in green digits, the OUT, AT, AL1 and AL2 indicators, and the SET, shift, decrease and increase keys
CHB702 front-panel layout: PV and SV rows, the output and alarm indicators, and the four keys. The CHB402 and CHB902 print the same layout on their own panel size.Open full diagram
Panel marking
PV
Measured temperature value, red upper row
SV
Temperature set point, green lower row
OUT
Main control output indicator
AT
Auto-tuning indicator
AL1 · AL2
Alarm output indicators 1 and 2
SET
Opens the parameter list and confirms an edit
≪
Shift key — moves between digits
∨
Decrease key
∧
Increase key

CH or CHB

The same instrument family inside: the same ten input types, the same relay-plus-SSR output, the same six code positions. What separates them is the front - the panel layout and the look - and the program, which differs slightly. The CH is the one that sells, so it is the safe default unless a customer asks for the CHB.

CHBCH
Inputten types, selectablethe same ten types
Outputrelay and SSR drive togetherrelay and SSR drive together
Code positionsthe same sixthe same six
Front and layoutits own panel arrangementits own, and the one that sells
Programslightly differentslightly different

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

CHB401

48 × 48mm (1/16 DIN) · cut-out 45 × 45mm

CHB402

48 × 96mm (1/8 DIN) · cut-out 45 × 92mm

CHB702

72 × 72mm · cut-out 68 × 68mm

CHB902

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

Wiring

Three arrangements for the CHB bodies — a contactor, a solid state relay and an alarm light — plus the terminal reference they all share. The block looks identical in each case; what changes is the jumper, and that is the part worth checking before you power up.

AC contactor and solid state relay wiring

AC contactor and solid state relay wiring

Contactor version: supply on 8 and 9, 9–13 jumper, and the relay closes 12 to 13 so the coil sits on A2 with A1 on neutral; the heater hangs across T1 and T2. SSR version: no jumper at all — the 12 VDC drive leaves on 11 (+) and 10 (−) and the module carries the heater current.

Alarm light wiring and the terminal reference

Alarm light wiring and the terminal reference

Alarm version: 9–2 jumper, with ALM1 switching 250 VAC 5 A across 2 and 3. The reference underneath gives every group: 220 VAC on 8 / 9, SSR drive 10 / 11, relay output 12 / 13 / 14, ALM1 on 2 / 3, and the sensor on 5 / 6 / 7.

Sensor, all versions: thermocouple red to 7 (+), blue to 6 (−); three-wire RTD with A on 5 and B on 6 and 7. Download the sheets (PDF)

Documents for this family

All documents

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What panel size and cut-out does the CHB need?

48×48×82, 48×96×75, 72×72×73 and 96×96×66 mm. The cut-out is 45×45, 45×92, 68×68 and 92×92 mm

Which sensors can the CHB read?

K, E, J, S, R, B, N and T thermocouples, plus Pt100 and Cu50

What output options does the CHB have?

two outputs on one instrument: a relay contact and an SSR drive

What supply voltage does the CHB need?

220 VAC, 50/60 Hz, with a 380 V build

How accurate is the CHB?

±0.5% or ±1.0% FS

Does the CHB have alarm outputs?

full-range setting

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.