Temperature Controllers
CHB402FK02-M*AN — CHB402 with built-in electromechanical relay
The version to order when the controller only has to close a contactor coil, or a small heater under 3A.

- Output
- Built-in electromechanical relay, 250VAC 3A, dry contact
- Bezel
- 48 × 96
- Panel cut-out
- 45 × 92
Technical specifications
| Series | CHB series PID temperature controller |
|---|---|
| Models | CHB401 / CHB402 / CHB702 / CHB902 |
| Panel sizes | 48×48×82, 48×96×75, 72×72×73 and 96×96×66 mm |
| Panel cutouts | 45×45, 45×92, 68×68 and 92×92 mm |
| Supply | 220 VAC, 50/60 Hz, with a 380 V build |
| Accuracy | ±0.5% or ±1.0% FS |
| Control | PID with autotuning, and on/off with an adjustable differential |
| Input | K, E, J, S, R, B, N and T thermocouples, plus Pt100 and Cu50 |
| Output | two outputs on one instrument: a relay contact and an SSR drive |
| Alarm | full-range setting |
| Operating environment | 0–50 °C, 30–85% RH, no corrosive gas |
Product overview
Part no. SE-CHB
Also known as: CHB temperature controller · CHB PID controller
The CHB is the CH body built with both outputs fitted: a relay contact and an SSR drive on the same instrument, so a machine that heats through a contactor and a solid state relay does not need two controllers. Ten input types, PID with autotuning, and a full-range alarm setting.
Ordering code
CHB402FK02-M*AN
The version to order when the controller only has to close a contactor coil, or a small heater under 3A.
| Order code | CHB402FK02-M*AN |
|---|---|
| Bezel (mm) | 48 × 96 |
| Cut-out (mm) | 45 × 92 |
| Output | Built-in electromechanical relay, 250VAC 3A, dry contact |
| Output terminals | on the case diagram |
| Input | Universal, K thermocouple fitted |
| Alarm | Two relays, A to L selectable |
| Supply | 220VAC 50/60Hz, 10VA |
What it can switch: Switches a contactor coil or a heater up to 3A directly; anything larger needs a contactor or an SSR
Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.
Other output stages of the same bezel
Reading this order code
How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.
| Position | Reads | Meaning |
|---|---|---|
| 1 | CHB402 | 48 × 96 mm (1/8 DIN) bezel on a 45 × 92mm panel cut-out |
| 2 | F | Control mode: reverse acting, the usual choice for heating |
| 3 | K02 | Input: K thermocouple over 0–400 °C; other letters select J, E, N, T, R, S, B, Pt100 or Cu50 |
| 4 | M | Built-in electromechanical relay, 250VAC 3A, dry contact |
| 5 | *AN | Alarm pair: A is an upper deviation alarm, N leaves the second alarm off; N-24VDC or N-24VAC would set a low-voltage supply instead |
Key features
- CHB401 / CHB402 / CHB702 / CHB902
- Panel cutouts 45×45, 45×92, 68×68 and 92×92 mm
- K, E, J, S, R, B, N and T thermocouples, plus Pt100 and Cu50, selectable on the unit
- two outputs on one instrument: a relay contact and an SSR drive
- ±0.5% or ±1.0% FS accuracy, 220 VAC, 50/60 Hz, with a 380 V build supply
Works with
The parts that go into the same panel and are usually ordered with it.
Ordering & Selection Guide
Six positions after CHB, the same six the CH series uses: the panel size, the control action, the input and its range, the main output, then one letter for each alarm. The prefix is what tells the two apart at the counter.
① · Panel size (mm)
| 401 | 48×48×82, cut-out 45×45 |
| 402 | 48×96×75, cut-out 45×92 |
| 702 | 72×72×73, cut-out 68×68 |
| 902 | 96×96×66, cut-out 92×92 |
② · Control action
| F | PID, reverse action — heating |
| D | PID, direct action — cooling |
③ · Input type and range
| K02 | K thermocouple |
| E02 | E thermocouple |
| D10 | Pt100 RTD |
| P10 | Cu50 RTD |
④ · Main output
| M | Relay contact (RELAY) |
| V | Voltage pulse (SSR drive) |
| 8 | Current output 4–20 mA |
⑤⑥ · First and second alarm
| N | No alarm configured |
| A | Upper deviation |
| B | Lower deviation |
| C | Upper and lower deviation |
| D | Deviation band |
| E | Upper deviation, hold action |
| F | Lower deviation, hold action |
| G | Upper and lower deviation, hold action |
| H | Process high (absolute) |
| J | Process low (absolute) |
| K | Process high, hold action |
| L | Process low, hold action |
Worked example
CHB702FK02-MAB
72×72×73 on a 68×68 cut-out, reverse action for heating, K thermocouple input, relay as the main output, and the two alarms set to upper and lower deviation.
What this series is built as
Every CHB leaves the factory with two outputs on the same instrument, a relay contact and an SSR drive. Which one drives the heater is set in the parameters; both are wired to their own terminals, so a machine can heat through a contactor and switch a solid state relay from the same device.
Panel and keys
PV is the measured value, red and uppermost; SV is the set point, green and beneath it. The dot row under the display names what the instrument is doing: OUT while the main output is on, AT while auto-tuning runs, AL1 and AL2 when either alarm has tripped. Four keys below trim the set point and walk the parameter list.

- PV
- Measured temperature value, red upper row
- SV
- Temperature set point, green lower row
- OUT
- Main control output indicator
- AT
- Auto-tuning indicator
- AL1 · AL2
- Alarm output indicators 1 and 2
- SET
- Opens the parameter list and confirms an edit
- ≪
- Shift key — moves between digits
- ∨
- Decrease key
- ∧
- Increase key
CH or CHB
The same instrument family inside: the same ten input types, the same relay-plus-SSR output, the same six code positions. What separates them is the front - the panel layout and the look - and the program, which differs slightly. The CH is the one that sells, so it is the safe default unless a customer asks for the CHB.
| CHB | CH | |
|---|---|---|
| Input | ten types, selectable | the same ten types |
| Output | relay and SSR drive together | relay and SSR drive together |
| Code positions | the same six | the same six |
| Front and layout | its own panel arrangement | its own, and the one that sells |
| Program | slightly different | slightly different |
One page per order code
Every code this family ships, with the bezel, the output stage and the terminals that output uses.
Wiring
Three arrangements for the CHB bodies — a contactor, a solid state relay and an alarm light — plus the terminal reference they all share. The block looks identical in each case; what changes is the jumper, and that is the part worth checking before you power up.
AC contactor and solid state relay wiring
Contactor version: supply on 8 and 9, 9–13 jumper, and the relay closes 12 to 13 so the coil sits on A2 with A1 on neutral; the heater hangs across T1 and T2. SSR version: no jumper at all — the 12 VDC drive leaves on 11 (+) and 10 (−) and the module carries the heater current.
Alarm light wiring and the terminal reference
Alarm version: 9–2 jumper, with ALM1 switching 250 VAC 5 A across 2 and 3. The reference underneath gives every group: 220 VAC on 8 / 9, SSR drive 10 / 11, relay output 12 / 13 / 14, ALM1 on 2 / 3, and the sensor on 5 / 6 / 7.
Sensor, all versions: thermocouple red to 7 (+), blue to 6 (−); three-wire RTD with A on 5 and B on 6 and 7. Download the sheets (PDF)
Documents for this family
- CHB series wiring96 KB · 2026-11-18
- CHB Contactor22 KB · 2026-11-18
- CHB SSR21 KB · 2026-11-18
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 3 years
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Frequently asked questions
What panel size and cut-out does the CHB need?
48×48×82, 48×96×75, 72×72×73 and 96×96×66 mm. The cut-out is 45×45, 45×92, 68×68 and 92×92 mm
Which sensors can the CHB read?
K, E, J, S, R, B, N and T thermocouples, plus Pt100 and Cu50
What output options does the CHB have?
two outputs on one instrument: a relay contact and an SSR drive
What supply voltage does the CHB need?
220 VAC, 50/60 Hz, with a 380 V build
How accurate is the CHB?
±0.5% or ±1.0% FS
Does the CHB have alarm outputs?
full-range setting
Related guides
TCN4 Series PID Temperature Controller: Model Codes, Inputs, Outputs and Commissioning
A working reference for engineers specifying or commissioning a TCN4 series digital PID temperature controller: how the four panel sizes differ, which sensor inputs are accepted,…
Read guide Product Updates · 2024-02-05REX-C Series PID Temperature Controller: Input Codes, Output Codes and Panel Data
A specification and commissioning reference for the REX-C family: how the input and output code letters work, panel and cutout dimensions for each model, PID setting ranges and…
Read guide Product Updates · 2024-02-04CH Series PID Temperature Controller: Sizes, Input and Output Codes, Alarm Modes
Panel dimensions, cutouts, input and output option codes, alarm mode selection and commissioning notes for the CH (REX-CH) short-body PID temperature controller family.
Read guideRelated models
All Temperature Controllers
REX-C100/C400/C700/C900 Digital PID Temperature Controller
SE-C100
REX Series Digital PID Temperature Controller is a classic and reliable industrial temperature control instrument designed for heating, cooling, and…
View details
C700 Digital Temperature Controller, 72 × 72mm Panel Frame | Strong Electric
SE-C700
72×72mm · 68×68mm · 24mm overall, 20mm of it behind the panel
View details
TC4H Digital PID Temperature Controller
SE-TC4H
48×96mm (1/8 DIN) · 45×92mm · 75mm total, 71mm behind the panel
View details
TC4L Digital PID Temperature Controller
SE-TC4L
96×96mm (1/4 DIN) · 92×92mm · 75mm total, 71mm behind the panel
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.