Temperature Controllers

E5EN / E5EM Series Thumbwheel Temperature Controller

E5EN and E5EM thumbwheel-set controllers for injection moulding machines: 48×96mm front, ±1°C accuracy and ranges from 0–199°C to 0–999°C.

E5EN with its digital readout and E5EM with its ribbon indicator, both thumbwheel set
E5EN at the left with the four-digit readout, E5EM beside it with the ribbon indicator; both take their setpoint from the thumbwheel underneath.
Panel size
48×96mm (1/8 DIN)
Panel cutout
45×92mm
Control output
Relay contact
Supply voltage
220VAC, 50/60Hz
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesE5EN / E5EM Series (panel-mount thumbwheel-set temperature controller for injection moulding machines)
ModelsE5EN (0–399°C, 0–999°C) / E5EM (0–199°C, 0–399°C, 0–999°C), all K thermocouple
Setting methodThree-digit thumbwheel on the front — the setpoint is dialled in and stays readable as a number, with no menu to enter
DisplayDigital LED readout of the measured value; the setpoint is not repeated on the display
Control methodPID with auto-tuning, ON/OFF
InputK thermocouple
Temperature rangeE5EN 0–399°C or 0–999°C; E5EM 0–199°C, 0–399°C or 0–999°C
Control outputRelay contact
Relay contact rating10A contact, 800W resistive load
Alarm outputHigh-limit alarm
Supply voltage220VAC, 50/60Hz
Accuracy±1°C
Response time3s
Panel size48×96mm (1/8 DIN)
Panel cutout45×92mm
Weight0.264kg (E5EN) / 0.271kg (E5EM)
MountingPanel mount, snap-in clip; base-bolt terminals
CertificationCE

Product overview

Part no. SE-E5EN

Also known as: Omron E5EN · E5EN temperature controller · E5EN On/Off temperature controller · E5EN controlador de temperatura

E5EN and E5EM are the 48×96mm controllers used on injection moulding machines and extruder barrels, where several zones sit side by side in one panel. The setpoint is dialled in on a three-digit thumbwheel and stays readable as a number, so an operator can see it and change it without entering a menu — which is what makes these the choice where a zone is set once per job. Both fit the same 45×92mm cutout and switch a 10A relay; the difference is the range ladder, with E5EM starting at 0–199°C for low-temperature zones and E5EN covering 0–399°C and 0–999°C. Accuracy is ±1°C and the response time 3s.

Key features

  • Three-digit thumbwheel setpoint on the front — no menu to enter, and the setting stays visible
  • 48×96mm front on a 45×92mm cutout — the standard moulding-machine zone size
  • E5EN 0–399°C and 0–999°C; E5EM 0–199°C, 0–399°C and 0–999°C
  • ±1°C accuracy, 3s response
  • 10A relay output with a high-limit alarm
  • K thermocouple input
  • PID with auto-tuning
  • 220VAC supply
  • CE marked

Works with

The parts that go into the same panel and are usually ordered with it.

Terminal connections and wiring

Eight terminals in one row. The thermocouple lands on 1 and 2, the supply on 5 and 3, and the relay output sits between 8 and 7. A link from 5 to 8 is what puts the live on the common of the contact, so without it the output switches nothing. The contact is dry and rated 5A: a heater inside that can hang straight off 7, anything larger needs a contactor.

Heater on the output contact

E5EM / E5EN220VAC supplyL on 5 · N on 3Heating elementThermocoupleblue (−)red (+)5–8 jumper87654321LN
LiveNeutralSensor signal

5 takes the live and 3 the neutral, and the link 5–8 makes 8 the live common. The contact closes 8 to 7, so the heater sits between 7 and the neutral on 3. Keep the load inside the 5A contact rating — a contact welded shut is what happens above it.

Contactor between the output and the load

E5EM / E5EN220VAC supplyL on 5 · N on 3ContactorA1L1L2L313NOA2T1T2T314NOHeating elementThermocoupleblue (−)red (+)5–8 jumper87654321LN
LiveNeutralSensor signal

7 now feeds A2 and A1 returns to the neutral on 3, so the controller only ever sees the coil current. The heater is switched by two poles: L2 takes the live and L1 the neutral, and T2 and T1 carry them down to the heater. L3, T3 and the auxiliary 13NO / 14NO stay unused on a single-phase load.

Wiring notes

  • The supply is 220 VAC across 5 and 3, with the live on 5. Terminals 4 and 6 stay empty on both of these diagrams.
  • 1 takes the red thermocouple lead and 2 the blue one. Reversed, the reading falls as the machine heats up — the usual first fault on a new version.
  • The output contact is rated 5A at 250 VAC resistive. A heater is resistive, a solenoid is not — derate for one, and fit a contactor above roughly 1kW.
  • With a contactor the coil goes on A1 and A2, never on the load terminals: a 5A contact closing a coil draws a fraction of what the heater does, and the contact lasts.

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.