Temperature Controllers

BT-72BD / BT-96BD / BT-72VD / BT-96VD Dial Temperature Controller

BT-72BD, BT-96BD, BT-72VD and BT-96VD dial controllers: 0–400°C range, ±1°C accuracy, 10A resistive load relay, 72×72 / 96×96mm bezels.

BT-96VD, BT-96BD, BT-72VD and BT-72BD dial temperature controllers, the V models with a printed dial and the B models with a three-digit thumbwheel
BT-72VD (72×72mm) and BT-72BD above, BT-96VD and BT-96BD (96×96mm) below; the V models take a printed dial, the B models a three-digit thumbwheel
Panel size
72×72 / 96×96mm
Panel cutout
68×68 / 92×92mm
Control output
Relay only
Supply voltage
220VAC 50/60Hz
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesBT-72BD / BT-96BD / BT-72VD / BT-96VD (dial-set panel-mount temperature controller)
ModelsBT-72BD and BT-96BD set on a three-digit thumbwheel; BT-72VD and BT-96VD on a printed dial. The digits are the bezel size, B marks the thumbwheel and V the dial.
Setting methodThree-digit thumbwheel on the B models, rotary dial with a pointer on the V models; both set one setpoint and read the measured value on the LED
DisplayRed three-digit LED, measured value only — the setpoint is read off the thumbwheel or the dial
Control methodTwo-position (ON/OFF) and time-proportioning control
Switching differentialSet by the ALS screw on the front panel (operating deviation adjustment)
InputK thermocouple as standard; E and Pt100 to order
Temperature range0–400°C
Resolution1°C
Control outputRelay only
Relay contact rating10A resistive load
Alarm outputAvailable on request. The ALARM lamp is fitted on the V models, so confirm the output count on the unit before ordering.
Supply voltage220VAC 50/60Hz
Accuracy±1°C
Front lampsGreen while the heater is on, red when it is off, and red when no thermocouple is connected
Panel size72×72 / 96×96mm
Panel cutout68×68 / 92×92mm
Dimensions (depth)108mm on the 72×72 and 125mm on the 96×96, behind the bezel
MountingPanel mount, snap-in clip
HousingABS, self-extinguishing
CertificationCE

Product overview

Part no. SE-BD-VDindustry model BD-VD

Also known as: BT-72BD / BT-96BD temperature controller · BT-72BD / BT-96BD On/Off dial temperature controller

The BT-72BD, BT-96BD, BT-72VD and BT-96VD set the temperature by hand and read the measured value off a red three-digit LED. The B models use a three-digit thumbwheel, the V models a printed dial with a pointer, and both carry one setpoint and one relay with no menu to walk through. The two digits in the code are the bezel size, and the range is 0–400°C with ±1°C accuracy — enough for sealing bars, drying ovens and small tanks.

Key features

  • Setpoint on a three-digit thumbwheel (B models) or a printed dial with a pointer (V models), visible on the front and hard to change by accident
  • Red three-digit LED readout of the measured temperature
  • Two-position (ON/OFF) and time-proportioning control
  • 0–400°C range on a K thermocouple, with E and Pt100 to order
  • Relay output — 10A resistive load
  • 72×72 / 96×96mm bezels on 68×68 / 92×92mm cut-outs
  • 108mm on the 72×72 and 125mm on the 96×96, behind the bezel
  • Switching differential set by the ALS screw on the front panel, not in a menu
  • Front lamps for heater on, heater off and a disconnected thermocouple
  • ABS, self-extinguishing housing, CE marked

Works with

The parts that go into the same panel and are usually ordered with it.

Model selection

ModelSetpointPanel sizePanel cut-outDepthWeight
BT-72BDThree-digit thumbwheel72×72mm68×68mm108mm0.240kg
BT-96BDThree-digit thumbwheel96×96mm92×92mm125mm0.315kg
BT-72VDRotary dial72×72mm68×68mm108mm0.255kg
BT-96VDRotary dial96×96mm92×92mm125mm0.330kg

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What panel size and cut-out does the BT-72BD / BT-96BD / BT-72VD / BT-96VD need?

72×72 / 96×96mm. The cut-out is 68×68 / 92×92mm

Which sensors can the BT-72BD / BT-96BD / BT-72VD / BT-96VD read?

K thermocouple as standard; E and Pt100 to order

What output options does the BT-72BD / BT-96BD / BT-72VD / BT-96VD have?

Relay only

What supply voltage does the BT-72BD / BT-96BD / BT-72VD / BT-96VD need?

220VAC 50/60Hz

How accurate is the BT-72BD / BT-96BD / BT-72VD / BT-96VD?

±1°C, at 1°C resolution

Does the BT-72BD / BT-96BD / BT-72VD / BT-96VD have alarm outputs?

Available on request. The ALARM lamp is fitted on the V models, so confirm the output count on the unit before ordering

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.