Variable Frequency Drives

H710 Series Full Vector Variable Frequency Drive

H710 full vector variable frequency drives from 0.75kW to 500kW with full vector control with encoderless speed regulation, V/F and torque control, in single-phase 220V and three-phase 380V input versions.

H710 series full vector variable frequency drives in four frame sizes
H710 full vector drives, 0.75 kW to 500 kW across four frame sizes.
Output
three-phase 220VAC or 380VAC, matched to the input configuration
Power range
0.75kW to 500kW
Input (220V builds)
single-phase 220VAC, 50/60Hz, up to 5.5kW
Input (380V builds)
three-phase 380VAC, 50/60Hz
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

ProductFull vector variable frequency drive for three-phase motor control
Power range0.75kW to 500kW
Input (220V builds)single-phase 220VAC, 50/60Hz, up to 5.5kW
Input (380V builds)three-phase 380VAC, 50/60Hz
Outputthree-phase 220VAC or 380VAC, matched to the input configuration
Controlfull vector control with encoderless speed regulation, V/F and torque control
Digital inputseight multi-function inputs X1 to X8, 0–24V level, 5mA, common COM
Analogue I/Otwo analogue inputs AI1 and AI2, two analogue outputs AO1 and AO2, 10V reference
Digital outputsY1 and Y2 open-collector outputs
Protectionover-current, over-voltage, under-voltage, over-heat, phase loss and short circuit
Coolingfan-cooled, wall or cabinet mounting
710 0.75 kW0.75 kW · 2.1 A · 1.05 kg
710 1.5 kW1.5 kW · 3.8 A · 1.05 kg
710 2.2 kW2.2 kW · 5.1 A · 1.1 kg
710 4.0 kW4.0 kW · 8.5 A · 2.75 kg
710 5.5 kW5.5 kW · 13 A · 2.85 kg
710 7.5 kW7.5 kW · 16 A · 2.9 kg
710 11 kW11 kW · 24 A · 3.3 kg
710 15 kW15 kW · 32 A · 5.6 kg
710 18.5 kW18.5 kW · 36 A · 5.65 kg
710 22 kW22 kW · 44 A · 5.85 kg
710 30 kW30 kW · 58 A · 16.1 kg
710 37 kW37 kW · 70 A · 16.3 kg
710 45 kW45 kW · 90 A · 22.75 kg
710 55 kW55 kW · 110 A · 23.05 kg
710 75 kW75 kW · 152 A · 37 kg
710 90 kW90 kW · 172 A · 37.75 kg
710 110 kW110 kW · 205 A · 38.5 kg
710 132 kW132 kW · 253 A · 59.5 kg
710 160 kW160 kW · 304 A · 61.5 kg

Product overview

Part no. SE-VFD-H710industry model VFD-H710

Also known as: H710 VFD · H710 frequency inverter · H710 variador de frecuencia

The H710 is the full-vector member of the range: it closes the loop on motor speed rather than holding a voltage-to-frequency ratio open, so torque holds at low speed and the drive recovers from a load step without stalling. Single-phase 220V versions run to 5.5kW, three-phase 380V versions to 500kW.

Key features

  • Power range from 0.75kW to 500kW
  • Full vector control with encoderless speed regulation
  • Eight multi-function digital inputs, X1 to X8
  • Two analogue inputs and two analogue outputs
  • Open-collector outputs Y1 and Y2
  • Single-phase 220V versions up to 5.5kW
  • Three-phase 380V versions from 0.75kW to 500kW
  • Fan-cooled, wall or cabinet mounting

Works with

The parts that go into the same panel and are usually ordered with it.

Panel and keys

The H710 operator is not the H350 one. Five lamps along the top report hertz, amps, volts, alarm and reverse; the display is five digits; and the eight keys cover program, function, up, down, shift, enter, run and stop-reset, with the speed knob on the right.

Operating panel of the H710 full vector drive
Operating panel of the H710 full vector drive

Lamps, left to right

HZdisplay shows frequency
Adisplay shows current
Vdisplay shows voltage
ALMfault present
REVrunning in reverse

Keys

PRGenter or leave the parameter menu
FUNCswitch what the display reports
▲ / ▼raise or lower the value
►move to the next digit
ENTERconfirm the setting
RUNstart
STOP / RESETstop, and clear a fault

Dimensions and weights

The installation distance is the hole spacing on the back of the case; the overall size is the space the drive needs, and the packing size is the carton the forwarder measures. Gross weight is what the freight quote is built on.

Single-phase 220V in, three-phase 220V out

PowerOutput currentHole spacing (mm)Overall (mm)Packing (mm)NetGross
0.75kW4.0A90*140152*102*140217*140*1851.1kg1.25kg
1.5kW7.0A90*140152*102*140217*140*1851.1kg1.25kg
2.2kW9.6A90*140152*102*140217*140*1851.1kg1.25kg
4kW17A128*228240*140*180302*185*2352.75kg3.2kg
5.5kW25A128*228240*140*180302*185*2352.85kg3.3kg

Three-phase 380V in, three-phase 380V out

PowerOutput currentHole spacing (mm)Overall (mm)Packing (mm)NetGross
0.75kW2.1A88*140151*100*138215*142*1831.05kg1.3kg
1.5kW3.8A88*140151*100*138215*142*1831.05kg1.35kg
2.2kW5.1A88*140151*100*138215*142*1831.05kg1.35kg
4kW8.5A107*202214*120*154265*170*2112.05kg2.45kg
5.5kW13A107*202214*120*154265*170*2112.05kg2.45kg
7.5kW16A128*228240*140*180302*185*2352.9kg3.35kg
11kW24A128*228240*140*180302*185*2353.3kg3.45kg
15kW32A187*305323*205*205395*285*3005.6kg6.5kg
18.5kW36A187*305323*205*205395*285*3005.75kg6.65kg
22kW44A187*305323*205*205395*285*3005.85kg6.75kg
30kW58A263*387407*283*200500*396*30511.4kg12.75kg
37kW70A263*387407*283*200500*396*30511.4kg12.75kg
45kW90A235*482510*320*256600*420*35522.75kg24.6kg
55kW110A235*482510*320*256600*420*35523.05kg24.9kg
75kW152A240*626650*380*275770*490*34337kg40.1kg
90kW172A240*626650*380*275770*490*34337.75kg41.5kg
110kW205A240*626650*380*275770*490*34338.5kg42.25kg
132kW253A320*730750*495*325870*635*50559.5kg69.5kg
160kW304A320*730750*495*325870*635*50561.5kg73kg
185kW350A320*730750*495*325870*635*50561.5kg73kg
200kW380A460*9801005*632*4401080*710*580117kg137kg
220kW426A460*9801005*632*4401080*710*580117kg137kg
250kW465A460*9801005*632*4401080*710*580117kg137kg
280kW520A460*9801005*632*4401080*710*580120kg140kg
315kW585A500*12001250*800*4501320*870*580175kg205kg
355kW650A500*12001250*800*4501320*870*580175kg205kg
400kW725A500*12001250*800*4501320*870*580180kg210kg
450kW820A500*12001250*800*4501320*870*580182kg212kg
500kW930A500*12001250*800*4501320*870*580182kg212kg

Wiring and terminals

One sheet carries both circuits. The main side is R, S and T in, U, V and W out to the motor, and a braking resistor across P and PB. The control side is everything else: seven digital inputs, two analogue inputs that take either a voltage or a current, two analogue outputs, two open-collector outputs, a pulse output, a relay and an RS485 pair.

Basic wiring diagram, H710 series
Basic wiring diagram, H710 series

Main circuit

TerminalFunction
R · S · TThree-phase 380V supply input
U · V · WOutput to the three-phase induction motor
P · PBBraking resistor across P and PB
PEProtective earth

Control circuit

TerminalFunction
X1 – X7Multi-function digital inputs
COMCommon for the digital inputs
+10VSupply for the speed potentiometer
AI1Analogue input 1, 0–10V or 4–20mA by jumper
AI2Analogue input 2, 0–10V or 4–20mA by jumper
+24V24V supply for the digital outputs
Y1 / Y2Open-collector outputs 1 and 2
DOPulse signal output
AO1 / AO2Analogue outputs, 0–10V or 4–20mA
GNDAnalogue common
TA · TB · TCRelay output, changeover contact
485+ / 485−RS485 communication pair

Supply & OEM

Available with your logoMOQ 5 units·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.