AC Contactors
LC2-D AC Contactor
Three and four pole AC contactor from 9 A to 170 A, with the coil voltage ordered by code and add-on blocks for the front and side auxiliaries.

- Standard
- IEC 60947-4-1 and GB 14048.4
- Ratings
- 9 A to 170 A in AC-3 at 380–440 V; up to 95 A at 690 V
- Utilisation
- AC-3 and AC-4
- Insulation
- Rated insulation voltage 690 V, rated impulse withstand 6 kV
Technical specifications
| Series | LC2-D AC contactor, three and four pole |
|---|---|
| Standard | IEC 60947-4-1 and GB 14048.4 |
| Ratings | 9 A to 170 A in AC-3 at 380–440 V; up to 95 A at 690 V |
| Utilisation | AC-3 and AC-4 |
| Insulation | Rated insulation voltage 690 V, rated impulse withstand 6 kV |
| Frequency | 50/60 Hz |
| Coil | 24 V to 660 V, code letter ordered with the model |
| Protection | IP20 |
| Ambient | −5 °C to +40 °C, 95 % RH maximum |
| Altitude | 2000 m or less |
| Flame resistance | V1 |
| Add-on blocks | LA1-DN on the front, LA8-DN at the side, LA2-DT or LA3-DR air delay head |
| Overload relay | LR2-D13 on 09 to 25, LR2-D23 on 32, LR2-D33 on 40 to 115, LR2-150 on 150 and 170 |
Product overview
Part no. SE-LC2-D
Also known as: Schneider LC2-D · LC2-D contactor · LC2-D AC contactor
The general-purpose contactor for motor starting and load switching: three or four poles, nine amps in AC-3 at 380–440 volts up to a hundred and seventy, and a coil ordered anywhere from twenty-four to six hundred and sixty volts. The frame takes auxiliary blocks on the front and at the side, an air delay head if the sequence needs one, and the matching thermal relay bolts straight underneath.
Key features
- 9 A to 170 A in AC-3 at 380–440 V
- Coil 24 V to 660 V by code
- Front and side auxiliary blocks
Works with
The parts that go into the same panel and are usually ordered with it.
Technical parameter
Thirteen frames from a ninth of the way up the range to the largest, in three-pole and four-pole versions. The table is the manufacturer's own, read across so a single column is one frame at every voltage.
| Model | 09 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 | 115 | 150 | 170 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Poles | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3 | 3 | 3 |
| Rated operational current, 200–240 V | 11 | 15 | 22 | 30 | 40 | 50 | 60 | 75 | 90 | 110 | 125 | 165 | 175 |
| Rated operational current, 380–440 V | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 | 115 | 150 | 170 |
| Rated operational current, 500–550 V | 7 | 9 | 12 | 18 | 21 | 34 | 39 | 42 | 49 | 59 | 100 | 120 | 125 |
| Rated operational current, 660–690 V | 7 | 9 | 12 | 18 | 24 | 34 | 39 | 42 | 49 | 59 | 100 | 120 | 125 |
| Conventional thermal current Ith | 20 | 25 | 32 | 40 | 50 | 60 | 80 | 80 | 125 | 125 | 200 | 250 | 250 |
| Rated power AC-3, 220/230/240 V (kW) | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 | 30 | 40 | 55 |
| Rated power AC-3, 380/400 V (kW) | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 |
| Rated power AC-3, 415 V (kW) | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | 45 | 45 | 55 | 75 | 90 |
| Rated power AC-3, 440 V (kW) | 4 | 5.5 | 9 | 11 | 15 | 22 | 30 | 37 | 45 | 45 | 55 | 75 | 90 |
| Rated power AC-3, 660/690 V (kW) | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 45 | 75 | 90 | 100 |
| Operating cycles per hour, AC-3 | 1200 | 1200 | 1200 | 1200 | 600 | 600 | 600 | 600 | 600 | 600 | 500 | 500 | 500 |
| Operating cycles per hour, AC-4 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 250 | 250 | 250 |
| Mechanical life, AC-3 (×10³) | 1000 | 1000 | 1000 | 1000 | 800 | 800 | 600 | 600 | 600 | 600 | 600 | 600 | 600 |
| Mechanical life, AC-4 (×10³) | 200 | 200 | 200 | 200 | 200 | 150 | 150 | 150 | 100 | 100 | 100 | 100 | 100 |
| Mechanical life (×10⁵) | 10 | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 |
| Matching fuse | RT16-20 | 20 | 32 | 40 | RT16-50 | 63 | 80 | 80 | 100 | 125 | 250 | 250 | 250 |
| Tightening torque (N·m) | 1.2 | 1.2 | 1.7 | 2.0 | 2.5 | 5 | 5 | 5 | 9 | 9 | 9 | 9 | 9 |
Making capacity is ten times the rated current in AC-3 and twelve times in AC-4; breaking capacity is eight and twelve respectively.
Selection and ordering
The frame is chosen by the motor's full-load current at the working voltage; the last two digits of the code then fix the contact arrangement. Two digits for a single auxiliary, three for the main poles alone, and the longer codes for the four-pole and mixed versions.
| Frames | Poles | Auxiliary | Type | Model |
|---|---|---|---|---|
| 9 A | 3 | 1 NO | 3NO+NO | LC2-D0910 |
| 9 A | 3 | 1 NC | 3NO+NC | LC2-D0901 |
| 9 A | 4 | — | 4NO | LC2-D09004 |
| 9 A | 2 | 2 | 2NO+2NC | LC2-D09008 |
| 12 A | 3 | 1 NO | 3NO+NO | LC2-D1210 |
| 12 A | 3 | 1 NC | 3NO+NC | LC2-D1201 |
| 12 A | 4 | — | 4NO | LC2-D12004 |
| 12 A | 2 | 2 | 2NO+2NC | LC2-D12008 |
| 18 A | 3 | 1 NO | 3NO+NO | LC2-D1810 |
| 18 A | 3 | 1 NC | 3NO+NC | LC2-D1801 |
| 25 A | 3 | 1 NO | 3NO+NO | LC2-D2510 |
| 25 A | 3 | 1 NC | 3NO+NC | LC2-D2501 |
| 25 A | 4 | — | 4NO | LC2-D25004 |
| 25 A | 2 | 2 | 2NO+2NC | LC2-D25008 |
| 32 A | 3 | 1 NO | 3NO+NO | LC2-D3210 |
| 32 A | 3 | 1 NC | 3NO+NC | LC2-D3201 |
| 40 A | 3 | 1 NO + 1 NC | 3NO+NO+NC | LC2-D4011 |
| 40 A | 4 | — | 4NO | LC2-D40004 |
| 40 A | 2 | 2 | 2NO+2NC | LC2-D40008 |
| 50 A | 3 | 1 NO + 1 NC | 3NO+NO+NC | LC2-D5011 |
| 50 A | 4 | — | 4NO | LC2-D50004 |
| 50 A | 2 | 2 | 2NO+2NC | LC2-D50008 |
| 65 A | 3 | 1 NO + 1 NC | 3NO+NO+NC | LC2-D6511 |
| 65 A | 4 | — | 4NO | LC2-D65004 |
| 65 A | 2 | 2 | 2NO+2NC | LC2-D65008 |
| 80 A | 3 | 1 NO + 1 NC | 3NO+NO+NC | LC2-D8011 |
| 80 A | 4 | — | 4NO | LC2-D80004 |
| 80 A | 2 | 2 | 2NO+2NC | LC2-D80008 |
| 95 A | 3 | 1 NO + 1 NC | 3NO+NO+NC | LC2-D9511 |
| 95 A | 4 | — | 4NO | LC2-D95004 |
| 95 A | 2 | 2 | 2NO+2NC | LC2-D95008 |
| 115 A | 3 | — | 3NO | LC2-D115 |
| 150 A | 3 | — | 3NO | LC2-D150 |
| 170 A | 3 | — | 3NO | LC2-D170 |
Coil voltage code
Two characters: the voltage, then the frequency. The same coil at fifty, sixty and fifty-sixty hertz carries three consecutive letters, so a B5 is the twenty-four volt coil at fifty hertz and a B7 the same coil for either.
| Coil (V) | 50 Hz | 60 Hz | 50/60 Hz |
|---|---|---|---|
| 24 V | B5 | B6 | B7 |
| 36 V | C5 | — | C7 |
| 48 V | E5 | E6 | E7 |
| 110 V | F5 | F6 | F7 |
| 127 V | G5 | G6 | G7 |
| 220 V | M5 | M6 | M7 |
| 230 V | P5 | P6 | P7 |
| 240 V | U5 | U6 | U7 |
| 380 V | Q5 | Q6 | Q7 |
| 415 V | N5 | N6 | N7 |
| 440 V | R5 | R6 | R7 |
| 480 V | T5 | T6 | T7 |
| 500 V | S5 | — | — |
| 600 V | — | S6 | — |
| 660 V | Y5 | — | — |
How the code reads
Frame current, then the contact arrangement. For the four-pole and mixed versions the last group reads as pole counts rather than a sequence number.
1LC22-D340411
- 1
LC2 series
- 2
D: three-pole or four-pole AC frame
- 3
Rated current at 380–440 V
- 4
Contact arrangement
Electrical life
Operating times against the current being broken, one line per frame. The vertical drop marks where a frame stops being economical at that current, which is the point to move up a size rather than keep replacing worn contacts.

Overall and mounting dimensions
Two bodies cover the range, so the table gives the outline of each and the fixing centres inside it. The last row is the only one that departs from the two bodies: the three largest frames are a deeper casting with a wider fixing span.

| Model | A | B | C | D | E | a | b | Φ |
|---|---|---|---|---|---|---|---|---|
| LC2-D09-12 | 47 | 76 | 82 | 113 | 133 | 34/35 | 50/60 | 2-/Φ4.5 |
| LC2-D18 | 47 | 76 | 87 | 118 | 138 | 34/35 | 50/60 | 2-/Φ4.5 |
| LC2-D25 | 57 | 86 | 95 | 126 | 146 | 40 | 48 | 2-/Φ4.5 |
| LC2-D32 | 57 | 86 | 100 | 131 | 151 | 40 | 48 | 2-/Φ4.5 |
| LC2-D40-65 | 77 | 129 | 116 | 145 | 165 | 40 | 100/110 | 3-/Φ6.5 |
| LC2-D80-95 | 87 | 129 | 127 | 156 | 176 | 40 | 100/110 | 3-/Φ6.5 |
| LC2-D09008-12008 | 47 | 76 | 82 | 113 | 133 | 34/35 | 50/60 | 2-/Φ4.5 |
| LC2-D25008 | 57 | 86 | 95 | 126 | 146 | 40 | 48 | 2-/Φ4.5 |
| LC2-D40008-65008 | 86 | 129 | 116/129 | 145 | 165 | 40 | 100/110 | 3-/Φ6.5 |
| LC2-D80008-95008 | 97 | 129 | 127/140 | 156 | 176 | 40 | 100/110 | 3-/Φ6.5 |
| LC2-D115-170 | 120 | 154 | 118 | — | — | 110 | 130 | 4-/Φ6.5 |
Accessories that fit every frame
One set of auxiliary blocks, one delay head and one reversing build cover the whole range, so a panel built around the small frames can grow without changing accessories.
| LA1-DN | front-mounted auxiliary contact block |
| LA8-DN | side-mounted auxiliary contact block |
| LA2-DT / LA3-DR | pneumatic time-delay head, on-delay or off-delay |
| LC2-DN | mechanical interlock for the reversing pair |
The overload relays listed against each frame in the technical table are the LR2-D family on this site, so a starter is ordered as one contactor plus one relay.
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All AC Contactors
LC2-Z DC Contactor
SE-LC2-Z
A contactor built for direct current: the arc does not cross zero on a DC circuit, so the chamber and the throw are made for it. Nine to ninety-five…
View details
LC2-N Reversing Contactor
SE-LC2-N
The reversing pair: two contactors on a common base with a mechanical interlock between them, so forward and reverse can never close together. Nine…
View details
LC6K Mini Contactor
SE-LC6K
The miniature body for the boxes where a standard contactor will not fit: six to sixteen amps in AC-3, a DC coil that stays silent when it pulls in,…
View details
CJX2 AC Contactor
SE-CJX2
A contactor is the mechanical answer to the same job a solid state relay does: switch a heater or a motor from a control signal. CJX2 covers the…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.