AC Contactors

LE1-D Magnetic Starter

A contactor and a thermal relay in one sealed enclosure, with start and stop on the lid: 9 A to 95 A and IP65, so a wet area needs no separate cabinet.

LE1-D contactor, 09, 12, 18, 25, 32, 40, 50, 65, 80 and 95
LE1-D: 09, 12, 18, 25, 32, 40, 50, 65, 80 and 95.
Standard
IEC 60947-4-1 and IEC 60943-1
Ratings
09, 12, 18, 25, 32, 40, 50, 65, 80 and 95
Voltage
Rated operational voltage 690 V, rated insulation 690 V, impulse withstand 8 kV
Frequency
50/60 Hz
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesLE1-D magnetic starter, contactor and thermal relay in one enclosure
StandardIEC 60947-4-1 and IEC 60943-1
Ratings09, 12, 18, 25, 32, 40, 50, 65, 80 and 95
VoltageRated operational voltage 690 V, rated insulation 690 V, impulse withstand 8 kV
Frequency50/60 Hz
ButtonsGreen start, red stop and reset on the lid
EnclosureDouble insulated IP65 on 09 to 32, metal IP65 on 40 to 95
LifeElectrical 5,000,000 operations; mechanical 50,000,000
Matching partsContactor LC2-D, thermal relay LR-D, both listed per model
Ambient−5 °C to +40 °C at 95 % RH; storage −40 °C to +75 °C; altitude 2000 m or less
LE1-D09contactor LC2-D09 · relay LR2-D13 · 2.2 kW at 220/230 V · 4 kW at 380/400 V · 4 kW at 415 V · 4 kW at 440 V · 5.5 kW at 660/690 V
LE1-D12contactor LC2-D12 · relay LR2-D13 · 3 kW at 220/230 V · 5.5 kW at 380/400 V · 5.5 kW at 415 V · 5.5 kW at 440 V · 7.5 kW at 660/690 V
LE1-D18contactor LC2-D18 · relay LR2-D13 · 4 kW at 220/230 V · 7.5 kW at 380/400 V · 9 kW at 415 V · 9 kW at 440 V · 10 kW at 660/690 V
LE1-D25contactor LC2-D25 · relay LR2-D13 · 5.5 kW at 220/230 V · 11 kW at 380/400 V · 11 kW at 415 V · 11 kW at 440 V · 15 kW at 660/690 V
LE1-D32contactor LC2-D32 · relay LR2-D13 · 7.5 kW at 220/230 V · 15 kW at 380/400 V · 15 kW at 415 V · 15 kW at 440 V · 18.5 kW at 660/690 V
LE1-D40contactor LC2-D40 · relay LR2-D33 · 11 kW at 220/230 V · 18.5 kW at 380/400 V · 22 kW at 415 V · 22 kW at 440 V · 30 kW at 660/690 V
LE1-D50contactor LC2-D50 · relay LR2-D33 · 15 kW at 220/230 V · 22 kW at 380/400 V · 25 kW at 415 V · 30 kW at 440 V · 33 kW at 660/690 V
LE1-D65contactor LC2-D65 · relay LR2-D33 · 18.5 kW at 220/230 V · 30 kW at 380/400 V · 37 kW at 415 V · 37 kW at 440 V · 37 kW at 660/690 V
LE1-D80contactor LC2-D80 · relay LR2-D33 · 22 kW at 220/230 V · 37 kW at 380/400 V · 45 kW at 415 V · 45 kW at 440 V · 45 kW at 660/690 V
LE1-D95contactor LC2-D95 · relay LR2-D33 · 25 kW at 220/230 V · 45 kW at 380/400 V · 45 kW at 415 V · 45 kW at 440 V · 45 kW at 660/690 V

Product overview

Part no. SE-LE1-D

Also known as: LE1-D contactor · LE1-D AC contactor

The contactor and the thermal relay already wired into one sealed box, with the start and stop buttons on the lid. Nine to ninety-five amps, IP65 whether the enclosure is the double-insulated one or the metal one, and the matching contactor and relay named against every model.

Key features

  • Contactor and relay in one enclosure
  • IP65, double insulated or metal
  • 9 A to 95 A

Works with

The parts that go into the same panel and are usually ordered with it.

Supply & OEM

Available with your logoMOQ 20 units·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related models

All AC Contactors

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.