LR-D Thermal Overload Relay
Overload relay that plugs onto the contactor: eighteen setting ranges from a tenth of an amp to thirty-eight, with manual or automatic reset.

- Function
- Thermal protection that plugs onto the contactor, with manual or automatic reset
- Auxiliary
- One normally open and one normally closed contact
- Tripping class
- Class 10 A
- Matching contactor
- LR-D13 on CJX2N-09 to 25, LR-D23 on CJX2N-32, LR-D33 on CJX2N-38; LR-K12 on CJX2-K06, K09 and K12
Technical specifications
| Series | LR-D thermal overload relay, with LR-K for the miniature frames |
|---|---|
| Function | Thermal protection that plugs onto the contactor, with manual or automatic reset |
| Auxiliary | One normally open and one normally closed contact |
| Tripping class | Class 10 A |
| Matching contactor | LR-D13 on CJX2N-09 to 25, LR-D23 on CJX2N-32, LR-D33 on CJX2N-38; LR-K12 on CJX2-K06, K09 and K12 |
| LR-D06 | Setting range 1 to 1.6 A |
| LR-D07 | Setting range 1.6 to 2.5 A |
| LR-D08 | Setting range 2.5 to 4 A |
| LR-D10 | Setting range 4 to 6 A |
| LR-D12 | Setting range 5.5 to 8 A |
| LR-D14 | Setting range 7 to 10 A |
| LR-D16 | Setting range 9 to 13 A |
| LR-D21 | Setting range 12 to 18 A |
| LR-D22 | Setting range 16 to 24 A |
| LR-D32 | Setting range 23 to 32 A |
| LR-D35 | Setting range 30 to 38 A |
| LR-K12 ranges | 0.1 to 0.16 A, 0.16 to 0.25 A, 0.25 to 0.4 A, 0.4 to 0.63 A, 0.63 to 1 A and 1 to 1.6 A |
| LR-F53/220 | Version for the F115 to F225 contactors |
| LR-F73/330 | Version for the F265 to F330 contactors |
Product overview
Part no. SE-LR-D
Also known as: Schneider LR-D · LR-D thermal overload relay · thermal overload relay
A contactor switches the motor; the thermal relay is what stops it cooking when the load jams. The LR-D range runs from a tenth of an amp to thirty-eight, in eighteen setting ranges, with manual or automatic reset and one changeover contact to drop the coil.
Key features
- 0.1 A to 38 A setting ranges
- Manual or automatic reset
- Plugs onto the CJX2N contactor
Works with
The parts that go into the same panel and are usually ordered with it.
Settings and tripping ranges
Two frame families cover the range: the D13, D23 and D33 blocks that clip straight under a contactor, and the larger D150 to D630 and F53/F73 units with busbar terminals for the heavy end. Protection is IP20 with the cover on, and the trip class is 10A throughout.
- Models
- LR2-D13 · D23 · D33 · D150 · D200 · D400 · D630 · LR2-F53 · F73
- Standard
- IEC 60947-4-1
- Approvals
- CE · CCC
- Tripping class
- 10A
- Rated insulation voltage Ui
- 690 / 1000 V
- Rated impulse withstand Uimp
- 6 / 8 kV
- Signalling
- Trip indicator
- Tightening torque
- 0.8 N·m
- Degree of protection
- IP20
- Ambient temperature
- −5 to +40°C, max 95% humidity
- Storage temperature
- −40 to +75°C
- Max operating altitude
- 2000 m
- Flame resistance
- V1
- Mounting
- Directly under the contactor
LR-D compact series for CJX2 contactors
A shorter frame that clips under the CJX2 range, with the same 1NO+1NC trip contact and a choice of manual or automatic reset. Two blocks cover the setting ranges: D06 to D14 up to 10A, then D16 to D35 through to 38A.
| Frame | Model | Setting range |
|---|---|---|
| D06 – D14 | ||
| LR-D06 | 1–1.6 | |
| LR-D07 | 1.6–2.5 | |
| LR-D08 | 2.5–4 | |
| LR-D10 | 4–6 | |
| LR-D12 | 5.5–8 | |
| LR-D14 | 7–10 | |
| D16 – D35 | ||
| LR-D16 | 9–13 | |
| LR-D21 | 12–18 | |
| LR-D22 | 16–24 | |
| LR-D32 | 23–32 | |
| LR-D35 | 30–38 | |
Reset mode, contact arrangement and the contactor each block clips onto, from the manufacturer's sheet.
Selection and ordering
The setting range is what gets ordered, not the motor rating: pick the relay whose range contains the motor's full-load current, and the table gives the fuse that protects it and the contactor it clips onto. Where two relays overlap, the wider one leaves room to adjust after commissioning.
| Frame | Model | Relay setting current | Setting range | aM fuse | gG fuse | Matched contactor |
|---|---|---|---|---|---|---|
| Frame 13 | ||||||
| 13 | LR2-D1301 | 0.16A | 0.10–0.16 | 0.25 | 2 | LC1-D09 |
| LR2-D1302 | 0.25A | 0.16–0.25 | 0.5 | 2 | LC1-D09 | |
| LR2-D1303 | 0.40A | 0.25–0.40 | 1 | 2 | LC1-D09 | |
| LR2-D1304 | 0.63A | 0.40–0.63 | 1 | 2 | LC1-D09 | |
| LR2-D1305 | 1.0A | 0.63–1.0 | 2 | 4 | LC1-D09 | |
| LR2-D1306 | 1.6A | 1.0–1.6 | 2 | 4 | LC1-D09 | |
| LR2-D1306X | 2.0A | 1.25–2.0 | 4 | 6 | LC1-D09 | |
| LR2-D1307 | 2.5A | 1.6–2.5 | 4 | 6 | LC1-D09 | |
| LR2-D1308 | 4.0A | 2.5–4.0 | 6 | 10 | LC1-D09 | |
| LR2-D1310 | 6.0A | 4.0–6.0 | 8 | 16 | LC1-D09 | |
| LR2-D1312 | 8.0A | 5.5–8.0 | 12 | 20 | LC1-D09 | |
| LR2-D1314 | 10A | 7–10 | 12 | 20 | LC1-D12 | |
| LR2-D1316 | 13A | 9–13 | 16 | 25 | LC1-D18 | |
| LR2-D1321 | 18A | 12–18 | 20 | 35 | LC1-D18 | |
| LR2-D1322 | 25A | 17–25 | 25 | 50 | LC1-D25 | |
| Frame 23 | ||||||
| 23 | LR2-D2353 | 32A | 23–32 | 40 | 63 | LC1-D32 |
| LR2-D2355 | 40A | 30–40 | 40 | 80 | LC1-D40 | |
| Frame 33 | ||||||
| 33 | LR2-D3353 | 32A | 23–32 | 40 | 63 | LC1-D32 |
| LR2-D3355 | 40A | 30–40 | 40 | 100 | LC1-D40 | |
| LR2-D3357 | 50A | 37–50 | 63 | 100 | LC1-D50 | |
| LR2-D3359 | 65A | 48–65 | 63 | 100 | LC1-D65 | |
| LR2-D3361 | 70A | 55–70 | 80 | 125 | LC1-D80 | |
| LR2-D3363 | 80A | 63–80 | 80 | 125 | LC1-D80 | |
| LR2-D3365 | 93A | 80–93 | 160 | 160 | LC1-D95 | |
| LR2-D150 | 150A | 80–150 | 200 | 250 | LC1-F115–F150 | |
| LR2-D200 | 200A | 120–200 | 315 | 315 | LC1-F115–F150 | |
| LR2-D400 | 400A | 160–400 | 400 | 630 | LC1-F225–F400 | |
| LR2-D630 | 630A | 315–630 | 630 | 800 | LC1-F330–F630 | |
F53 and F73 for the heavy end
The two bar-mounted families take over where the D-series stops. Same ordering rule: the range first, then the fuse, then the contactor it sits on.
| Model | Setting range | aM fuse | gG fuse | Matched contactor |
|---|---|---|---|---|
| LR2-F53/50 | 30–50 | 50 | 80 | LC1-F115–F185 |
| LR2-F53/80 | 48–80 | 80 | 125 | LC1-F115–F185 |
| LR2-F53/100 | 60–100 | 100 | 200 | LC1-F115–F185 |
| LR2-F53/150 | 90–150 | 160 | 250 | LC1-F115–F185 |
| LR2-F53/220 | 132–220 | 250 | 315 | LC1-F225–F265 |
| LR2-F73/330 | 200–330 | 400 | 500 | LC1-F225–F500 |
| LR2-F73/500 | 300–500 | 500 | 800 | LC1-F225–F500 |
| LR2-F73/630 | 380–630 | 630 | 800 | LC1-F400–F630 |
Tripping curve
Time against current, as a multiple of the setting. The solid line is a cold start and the dashed one a hot start; both are for the 10A class. A relay that trips too early on a hot restart is usually set too close to the motor's full-load current.


Separate mounting base
A relay does not have to sit under a contactor. The SAZ1 base carries it on 35mm rail or on screws, so an overload can protect a load that is switched elsewhere in the panel.
| Relay | Base |
|---|---|
| LR2-13 | SAZ1-13 |
| LR2-23 | SAZ1-23 |
| LR2-33 | SAZ1-33 |

Relay dimensions
45mm wide, 63mm high and 70 to 71mm deep for the compact frames, with the depth growing to 52mm at the D09 where the trip contact sits. The heavy families are drawn below at their own scale.


Circuit
Three main poles through 1-2, 3-4 and 5-6, one normally-closed trip contact across 95-96 and one normally-open across 97-98. Wire the trip contact into the contactor coil circuit, not into the load circuit.

Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All AC Contactors
Auxiliary Contacts and Delay Heads
SE-AUXILIARY-CONTAC
Everything that clips onto the contactor: front blocks from one NO up to four NC, a side block where the front is already full, air delay heads that…
View details
CJX2 AC Contactor
SE-CJX2
A contactor is the mechanical answer to the same job a solid state relay does: switch a heater or a motor from a control signal. CJX2 covers the…
View details
LC2-D AC Contactor
SE-LC2-D
The general-purpose contactor for motor starting and load switching: three or four poles, nine amps in AC-3 at 380–440 volts up to a hundred and…
View details
LC2-Z DC Contactor
SE-LC2-Z
A contactor built for direct current: the arc does not cross zero on a DC circuit, so the chamber and the throw are made for it. Nine to ninety-five…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.