AC Contactors
LC2-Z DC Contactor
Direct current contactor from 9 A to 95 A, up to 690 V, for battery, traction and capacitor circuits that need a DC-rated arc.

- Application
- DC power control, battery circuits and capacitor circuits; suitable for locomotives, diesel locomotives and electric train units
- Ratings
- Rated voltage up to 690 V, rated current up to 95 A
- Standard
- IEC 60947-4-1 and GB 14048.4
- Coil
- DC coil, voltage ordered with the model
Technical specifications
| Series | LC2-Z DC contactor, for direct current loads |
|---|---|
| Application | DC power control, battery circuits and capacitor circuits; suitable for locomotives, diesel locomotives and electric train units |
| Ratings | Rated voltage up to 690 V, rated current up to 95 A |
| Standard | IEC 60947-4-1 and GB 14048.4 |
| Coil | DC coil, voltage ordered with the model |
| Contacts | Main contacts plus auxiliary sets as the code shows |
| LC2-09Z | 2.2 kW / 3 HP at 200–240 V · 4 kW / 5.5 HP at 380–440 V · 5 kW / 7 HP at 500–550 V · 5.5 kW / 7.5 HP at 660–690 V · Ith 25 A |
| LC2-12Z | 3 kW / 4 HP at 200–240 V · 5.5 kW / 7.5 HP at 380–440 V · 7.5 kW / 10 HP at 500–550 V · 7.5 kW / 10 HP at 660–690 V · Ith 25 A |
| LC2-18Z | 4 kW / 5.5 HP at 200–240 V · 7.5 kW / 10 HP at 380–440 V · 9 kW / 12 HP at 500–550 V · 10 kW / 13.5 HP at 660–690 V · Ith 32 A |
| LC2-25Z | 5.5 kW / 7.5 HP at 200–240 V · 11 kW / 15 HP at 380–440 V · 15 kW / 20 HP at 500–550 V · 15 kW / 20 HP at 660–690 V · Ith 40 A |
| LC2-32Z | 7.5 kW / 10 HP at 200–240 V · 15 kW / 20 HP at 380–440 V · 18.5 kW / 25 HP at 500–550 V · 18.5 kW / 25 HP at 660–690 V · Ith 50 A |
| LC2-40Z | 11 kW / 15 HP at 200–240 V · 18.5 kW / 25 HP at 380–440 V · 30 kW / 40 HP at 500–550 V · 30 kW / 40 HP at 660–690 V · Ith 60 A |
| LC2-50Z | 15 kW / 20 HP at 200–240 V · 22 kW / 30 HP at 380–440 V · 37 kW / 50 HP at 500–550 V · 37 kW / 50 HP at 660–690 V · Ith 80 A |
| LC2-65Z | 18.5 kW / 25 HP at 200–240 V · 30 kW / 40 HP at 380–440 V · 37 kW / 50 HP at 500–550 V · 37 kW / 50 HP at 660–690 V · Ith 80 A |
| LC2-80Z | 22 kW / 30 HP at 200–240 V · 37 kW / 50 HP at 380–440 V · 45 kW / 60 HP at 500–550 V · 45 kW / 60 HP at 660–690 V · Ith 110 A |
| LC2-95Z | 25 kW / 35 HP at 200–240 V · 45 kW / 60 HP at 380–440 V · 45 kW / 60 HP at 500–550 V · 45 kW / 60 HP at 660–690 V · Ith 130 A |
Product overview
Part no. SE-LC2-Z
Also known as: Schneider LC2-Z · LC2-Z contactor · LC2-Z AC contactor
A contactor built for direct current: the arc does not cross zero on a DC circuit, so the chamber and the throw are made for it. Nine to ninety-five amps up to 690 volts, for battery banks, traction auxiliary circuits and capacitor switching.
Key features
- Direct current, up to 690 V and 95 A
- Traction and battery duties
- DC coil ordered by voltage
Works with
The parts that go into the same panel and are usually ordered with it.
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All AC Contactors
LC2-D AC Contactor
SE-LC2-D
The general-purpose contactor for motor starting and load switching: three or four poles, nine amps in AC-3 at 380–440 volts up to a hundred and…
View details
LC2-N Reversing Contactor
SE-LC2-N
The reversing pair: two contactors on a common base with a mechanical interlock between them, so forward and reverse can never close together. Nine…
View details
LC6K Mini Contactor
SE-LC6K
The miniature body for the boxes where a standard contactor will not fit: six to sixteen amps in AC-3, a DC coil that stays silent when it pulls in,…
View details
CJ19 Capacitor Contactor
SE-CJ19
Made for capacitors rather than motors: the damping device is inside the case, so the closing surge is held to twenty times the rated current and the…
View detailsNeed help selecting the right model?