AC Contactors

CJ20 AC Contactor

The open-frame contactor for the big circuits: ten to six hundred and thirty amps, up to 660 V, with the coil wound for AC or DC control.

CJ20 contactor, AC 50 Hz at 110, 127, 220 or 380 V; DC at 110 or 220 V
CJ20: AC 50 Hz at 110, 127, 220 or 380 V; DC at 110 or 220 V; Remote making and breaking in circuits at 50 or 60 Hz…; Two normally open and two normally closed on the small frames, contact rating AC-15 500 VA and DC-13 60 W.
Use
Remote making and breaking in circuits at 50 or 60 Hz, working voltage up to 660 V and rated current up to 630 A
Standard
GB 14048.5 and IEC 60947-5-1
Coil
AC 50 Hz at 110, 127, 220 or 380 V; DC at 110 or 220 V
Life
CJ20-10 to CJ20-160 at 10,000,000 mechanical operations; CJ20-250 to CJ20-630 at 6,000,000
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesCJ20 AC contactor
UseRemote making and breaking in circuits at 50 or 60 Hz, working voltage up to 660 V and rated current up to 630 A
StandardGB 14048.5 and IEC 60947-5-1
CoilAC 50 Hz at 110, 127, 220 or 380 V; DC at 110 or 220 V
LifeCJ20-10 to CJ20-160 at 10,000,000 mechanical operations; CJ20-250 to CJ20-630 at 6,000,000
Ambient−5 °C to +40 °C averaged over 24 hours; altitude 2000 m or less
InstallationClass III, tilt no more than 5° from vertical
PollutionDegree 3
AuxiliaryTwo normally open and two normally closed on the small frames, contact rating AC-15 500 VA and DC-13 60 W
CJ20-10Ith 10 A · 2.2 kW at 220 V · 4 kW at 380 V · 4 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 65 VA / 9 VA · fuse RT16-20
CJ20-16Ith 16 A · 4.5 kW at 220 V · 7.5 kW at 380 V · 11 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 62 VA / 9.5 VA · fuse RT16-32
CJ20-25Ith 32 A · 5.5 kW at 220 V · 11 kW at 380 V · 13 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 93 VA / 14 VA · fuse RT16-50
CJ20-40Ith 55 A · 11 kW at 220 V · 22 kW at 380 V · 22 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 175 VA / 19 VA · fuse RT16-80
CJ20-63Ith 80 A · 18 kW at 220 V · 30 kW at 380 V · 35 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 480 VA / 57 VA · fuse RT16-160
CJ20-100Ith 125 A · 28 kW at 220 V · 50 kW at 380 V · 50 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 570 VA / 61 VA · fuse RT16-250
CJ20-160Ith 200 A · 48 kW at 220 V · 85 kW at 380 V · 85 kW at 660 V · 600 operations an hour · AC-3 life 100 ×10⁴ · coil 855 VA / 85.5 VA · fuse RT16-315
CJ20-250Ith 315 A · 80 kW at 220 V · 132 kW at 380 V · — kW at 660 V · 600 operations an hour · AC-3 life 60 ×10⁴ · coil 1710 VA / 152 VA · fuse RT16-400
CJ20-400Ith 400 A · 115 kW at 220 V · 200 kW at 380 V · 220 kW at 660 V · 600 operations an hour · AC-3 life 60 ×10⁴ · coil 1710 VA / 250 VA · fuse RT16-500
CJ20-630Ith 630 A · 175 kW at 220 V · 300 kW at 380 V · — kW at 660 V · 600 operations an hour · AC-3 life 60 ×10⁴ · coil 3578 VA / 91.2 VA · fuse RT16-630

Product overview

Part no. SE-CJ20

Also known as: CJ20 contactor · CJ20 AC contactor

The open-frame contactor, the one that shows its arc chutes: ten to six hundred and thirty amps, up to six hundred and sixty volts, and a coil wound for AC or DC as the control circuit is. The large frames take the auxiliary contacts on the front and the thermal relay underneath.

Key features

  • 10 A to 630 A open frame
  • Coil AC 110 to 380 V or DC 110 to 220 V
  • Auxiliary contacts on the front

Works with

The parts that go into the same panel and are usually ordered with it.

How the code reads

The open-frame code is short: the family, the design number, the current in amps, one letter for the energy-saving version, and a suffix that states the auxiliary contact voltage. Everything a quote needs is in those five places, which is why the catalogue asks for the code rather than the current alone.

1CJ220-3□4□/506

  1. 1

    AC contactor

  2. 2

    Design sequence number

  3. 3

    Rated operational current in amps, at 380 V in AC-3

    10, 16, 25, 40, 63, 100, 160, 250, 400 or 630

  4. 4

    Derivative code

    Blank: standard · S: AC and DC energy-saving type

    The energy-saving versions start at CJ20-63 and above

  5. 5

    Auxiliary specification code

    06 states 660 V for the auxiliary circuit

Three codes, decoded

The same family at three sizes: the small frame most panels use, the energy-saving version that starts at 63 A, and the 660 V auxiliary suffix.

  • CJ20-25/06

    25 A frame, standard version, 660 V auxiliary circuit

  • CJ20-63S/06

    63 A with the energy-saving coil, the smallest frame that offers it

  • CJ20-400/06

    400 A frame for the main incomer of a panel

Supply & OEM

Available with your logoMOQ 20 units·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related models

All AC Contactors

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.