AC Contactors
CJ20 AC Contactor
The open-frame contactor for the big circuits: ten to six hundred and thirty amps, up to 660 V, with the coil wound for AC or DC control.

- Use
- Remote making and breaking in circuits at 50 or 60 Hz, working voltage up to 660 V and rated current up to 630 A
- Standard
- GB 14048.5 and IEC 60947-5-1
- Coil
- AC 50 Hz at 110, 127, 220 or 380 V; DC at 110 or 220 V
- Life
- CJ20-10 to CJ20-160 at 10,000,000 mechanical operations; CJ20-250 to CJ20-630 at 6,000,000
Technical specifications
| Series | CJ20 AC contactor |
|---|---|
| Use | Remote making and breaking in circuits at 50 or 60 Hz, working voltage up to 660 V and rated current up to 630 A |
| Standard | GB 14048.5 and IEC 60947-5-1 |
| Coil | AC 50 Hz at 110, 127, 220 or 380 V; DC at 110 or 220 V |
| Life | CJ20-10 to CJ20-160 at 10,000,000 mechanical operations; CJ20-250 to CJ20-630 at 6,000,000 |
| Ambient | −5 °C to +40 °C averaged over 24 hours; altitude 2000 m or less |
| Installation | Class III, tilt no more than 5° from vertical |
| Pollution | Degree 3 |
| Auxiliary | Two normally open and two normally closed on the small frames, contact rating AC-15 500 VA and DC-13 60 W |
| CJ20-10 | Ith 10 A · 2.2 kW at 220 V · 4 kW at 380 V · 4 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 65 VA / 9 VA · fuse RT16-20 |
| CJ20-16 | Ith 16 A · 4.5 kW at 220 V · 7.5 kW at 380 V · 11 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 62 VA / 9.5 VA · fuse RT16-32 |
| CJ20-25 | Ith 32 A · 5.5 kW at 220 V · 11 kW at 380 V · 13 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 93 VA / 14 VA · fuse RT16-50 |
| CJ20-40 | Ith 55 A · 11 kW at 220 V · 22 kW at 380 V · 22 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 175 VA / 19 VA · fuse RT16-80 |
| CJ20-63 | Ith 80 A · 18 kW at 220 V · 30 kW at 380 V · 35 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 480 VA / 57 VA · fuse RT16-160 |
| CJ20-100 | Ith 125 A · 28 kW at 220 V · 50 kW at 380 V · 50 kW at 660 V · 1200 operations an hour · AC-3 life 100 ×10⁴ · coil 570 VA / 61 VA · fuse RT16-250 |
| CJ20-160 | Ith 200 A · 48 kW at 220 V · 85 kW at 380 V · 85 kW at 660 V · 600 operations an hour · AC-3 life 100 ×10⁴ · coil 855 VA / 85.5 VA · fuse RT16-315 |
| CJ20-250 | Ith 315 A · 80 kW at 220 V · 132 kW at 380 V · — kW at 660 V · 600 operations an hour · AC-3 life 60 ×10⁴ · coil 1710 VA / 152 VA · fuse RT16-400 |
| CJ20-400 | Ith 400 A · 115 kW at 220 V · 200 kW at 380 V · 220 kW at 660 V · 600 operations an hour · AC-3 life 60 ×10⁴ · coil 1710 VA / 250 VA · fuse RT16-500 |
| CJ20-630 | Ith 630 A · 175 kW at 220 V · 300 kW at 380 V · — kW at 660 V · 600 operations an hour · AC-3 life 60 ×10⁴ · coil 3578 VA / 91.2 VA · fuse RT16-630 |
Product overview
Part no. SE-CJ20
Also known as: CJ20 contactor · CJ20 AC contactor
The open-frame contactor, the one that shows its arc chutes: ten to six hundred and thirty amps, up to six hundred and sixty volts, and a coil wound for AC or DC as the control circuit is. The large frames take the auxiliary contacts on the front and the thermal relay underneath.
Key features
- 10 A to 630 A open frame
- Coil AC 110 to 380 V or DC 110 to 220 V
- Auxiliary contacts on the front
Works with
The parts that go into the same panel and are usually ordered with it.
How the code reads
The open-frame code is short: the family, the design number, the current in amps, one letter for the energy-saving version, and a suffix that states the auxiliary contact voltage. Everything a quote needs is in those five places, which is why the catalogue asks for the code rather than the current alone.
1CJ220-3□4□/506
- 1
AC contactor
- 2
Design sequence number
- 3
Rated operational current in amps, at 380 V in AC-3
10, 16, 25, 40, 63, 100, 160, 250, 400 or 630
- 4
Derivative code
Blank: standard · S: AC and DC energy-saving type
The energy-saving versions start at CJ20-63 and above
- 5
Auxiliary specification code
06 states 660 V for the auxiliary circuit
Three codes, decoded
The same family at three sizes: the small frame most panels use, the energy-saving version that starts at 63 A, and the 660 V auxiliary suffix.
CJ20-25/06
25 A frame, standard version, 660 V auxiliary circuit
CJ20-63S/06
63 A with the energy-saving coil, the smallest frame that offers it
CJ20-400/06
400 A frame for the main incomer of a panel
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All AC Contactors
CJ19 Capacitor Contactor
SE-CJ19
Made for capacitors rather than motors: the damping device is inside the case, so the closing surge is held to twenty times the rated current and the…
View details
LC2-Z DC Contactor
SE-LC2-Z
A contactor built for direct current: the arc does not cross zero on a DC circuit, so the chamber and the throw are made for it. Nine to ninety-five…
View details
LC2-N Reversing Contactor
SE-LC2-N
The reversing pair: two contactors on a common base with a mechanical interlock between them, so forward and reverse can never close together. Nine…
View details
CJX2-F Reversing Contactor
SE-CJX2-F
The large F frames built as a reversing pair: two contactors side by side with the interlocking bar across them, so a forward command cannot meet a…
View detailsNeed help selecting the right model?