REX-C900 96 × 96 mm (1/4 DIN) 220VAC digital PID temperature controller

96 × 96 mm (1/4 DIN) bezel, 92 × 92mm cut-out. 110mm deep. Three output stages are ordered in this bezel, each with its own order code.

Download manual (PDF) · 12 pages

Ordering & Selection Guide

Five positions. The bezel is the model number itself, then the control mode, the input and its range, the output, and the alarm pair.

PositionOrder codeWhat it selects
1REX-C100 / C400 / C700 / C900Case size: 48 × 48, 48 × 96, 72 × 72 or 96 × 96mm
2FControl mode: F reverse acting for heating, D direct acting for cooling
3K02Input and its range: K02 is a K thermocouple over 0–400 °C; other letters select J, R, S, B, E, N, T, Pt100, Cu50 or a linear signal
4M / V / 8 / gOutput stage: M relay 250VAC 3A, V SSR drive switching 0/12 V DC, 8 current 4–20mA, g zero-crossing trigger pulse for an external triac
5*ANAlarm pair: the first letter is alarm 1 and the second is alarm 2, each one of N none, A deviation high, B deviation low, C deviation both ways, D band, E deviation high held, F deviation low held, G deviation both ways held, H process high, J process low, K process high held, L process low held; the letters after the first may also set the input option (N multiple inputs, B alarm 2 fitted, N-DA K input only, N-24VAC or N-24VDC for a low-voltage supply)

Technical specifications

Accuracy±0.5 %FS ±1 °C
Supply voltage220VAC 50/60Hz, 10VA
Control methodPID with autotuning, or ON/OFF
IndicationDual 4-digit 7-segment LED, PV red above SV green
Setting methodFront-panel membrane keys
AlarmsTwo relay outputs, N or A to L selectable
Operating environment0–50 °C, 30–85 %RH, no condensation

Output types

PositionOutputLoad
MElectromagnetic relayContact rating 3A at 250VAC. Switches a contactor coil or a small heater directly. The terminal pair is printed on the case diagram and differs between models.
VSSR drive SE-SSR-DAVoltage pulse 0–12VDC for an external solid state relay. The load current becomes the relay's rating.
8Current output4–20mA analogue output for an SCR power regulator, a recorder or a PLC input.
gTriac, zero crossingZero-crossing trigger pulse for a thyristor module; used on older panels and rebuilt furnaces.

Inputs and the probe that suits each

Order codeOutputRangeProbe
KThermocouple0–1372 °C (K02 setting: 0–400 °C)SE-TC-WRNK236
JThermocouple0–750 °C—
EThermocouple0–1000 °CSE-TC-RING
NThermocouple0–1300 °C—
TThermocouple−200–400 °C—
RThermocouple−50–1769 °C—
SThermocouple0–1769 °C—
BThermocouple−50–1769 °C—
Pt100RTD−199.9–649.0 °CSE-RTD-PT100
Cu50RTD−50.0–150.0 °CSE-RTD-CU50
0–5V / 1–5VLinear0.0–100.0 (scaled)—
0–20mA / 4–20mALinear0.0–100.0 (scaled)—

Order codes of this bezel

NoOrder codeOutputTerminals
1REX-C900FK02-M*ANBuilt-in electromechanical relay, 250VAC 3A, dry contacton the case diagram
2REX-C900FK02-V*ANVoltage pulse output, 0–12VDC, for an external solid state relayon the case diagram
3REX-C900FK02-8*ANAnalogue current output, 4–20mA (0–10mA on request)on the case diagram

Dimensions

REX-C900 general arrangement

General arrangement: bezel, the two bodies behind the panel, and the panel cut-out. The full sheet is sent with the quotation.