Solid State Relays & SCR Power Modules
SSR Heatsink / Aluminum Heat Sink for Solid State Relay
SSR heatsink radiator for solid state relays, with aluminium heat dissipation for 10A-120A SSR modules in heating and automation systems.

- Material
- Extruded aluminium alloy
- Construction
- Multi-fin extrusion with a flat mounting face
- Stock profiles
- 11 families: I, W, T, Ib, Ic, TH, D, E, H, F and Y; availability confirmed by quotation
- Relay mounting
- Single-phase panel-mount SSRs fix on 48mm hole centres; three-phase blocks bolt through their own footprint
Technical specifications
| Material | Extruded aluminium alloy |
|---|---|
| Construction | Multi-fin extrusion with a flat mounting face |
| Stock profiles | 11 families: I, W, T, Ib, Ic, TH, D, E, H, F and Y; availability confirmed by quotation |
| Relay mounting | Single-phase panel-mount SSRs fix on 48mm hole centres; three-phase blocks bolt through their own footprint |
| Finish | Mill finish as standard; black anodizing to order |
| Manufacturing Options | Custom cutting, rapid tooling, CNC machining, anodizing |
| Installation | Screw-fixed through the channels in the base |
| Fan Mounting | Cooling fan option on H-110/H-150 (80×80×30mm) and F-120 (90×90×30mm); confirm fan fit per profile |
| Properties | Corrosion resistant, wear resistant, heat resistant |
Product overview
Part no. SE-HS-SSRindustry model HS-SSR
Also known as: SSR heat sink · heat sink for solid state relay
SSR Heatsink is an aluminium extrusion heat sink for solid state relay modules used in heating, temperature control, motor control, and industrial automation systems. It spreads the heat the relay generates and holds its base down where the module keeps its rating, so the relay survives continuous load instead of derating or failing early. The catalogue is organised into 11 profile families: I, W, T, Ib, Ic, TH, D, E, H, F and Y. Confirm the mounting dimensions and application-specific thermal requirements before ordering.
Key features
- Extruded aluminium profile with a flat machined face, so the relay base sits on metal rather than on a casting skin
- 11 profile families for single-phase, DIN-rail and three-phase applications; confirm mechanical fit and thermal requirements
- Single-phase profiles use the standard panel-mount hole centres, so a standard SSR drops straight on
- Drilled for a side fan; the fan size follows the profile width
- Screw channels run the length of the base, so the assembly fixes down without a separate nut
- Recommended for SSR loads above 10A, where a bare relay would derate or fail early
- Cut to length, drilled, tapped and anodized to order
- Suitable for heating equipment, control cabinets and machine panels
Works with
The parts that go into the same panel and are usually ordered with it.
Heat sink sizing by relay current
An SSR drops about 1.6 V whatever the load, so the heat it makes is the current times that drop: 40 A is roughly 64 W inside a box the size of a matchbox. The relay's rating only holds with a sink under it, and the sink has to be at or below the thermal resistance in this table.
| Relay current | Heat in the relay | Heat sink at or below | Mounting |
|---|---|---|---|
| 10 A | 16 W | ≤ 5.0 °C/W | Plate 80 × 50 mm |
| 15 A | 24 W | ≤ 3.0 °C/W | Plate 100 × 60 mm |
| 25 A | 40 W | ≤ 2.0 °C/W | Finned 100 × 80 mm |
| 40 A | 64 W | ≤ 1.2 °C/W | Finned 120 × 100 mm |
| 60 A | 96 W | ≤ 0.8 °C/W | Finned 150 × 120 mm, fan assisted |
| 80 A | 128 W | ≤ 0.6 °C/W | Finned 200 × 120 mm, fan assisted |
| 100 A | 160 W | ≤ 0.45 °C/W | Finned 250 × 120 mm, forced air |
Figures assume an ambient of 40 °C, a junction limit of 125 °C and thermal paste between relay and sink. Above 40 °C ambient, derate the current by about 1 % per °C, or fit the next size of sink. A relay mounted without a sink carries a fraction of its rating.
11 heatsink profile families (single-phase, DIN rail & three-phase)
Pick your group below — each card shows the extruded profile, cross-section dimensions (mm), rated SSR current and fan/DIN-rail options.
Single-phase panel mount (≤ 15 A – 80 A)
Standard extruded blocks for single-phase SSR-DA / AA / LA modules.





TS35 DIN-rail mount (≤ 40 A)
Factory-fitted with a TS35 DIN-rail clip for compact control cabinets.


Three-phase & industrial high-current (40 A – 250 A)
Heavy-duty blocks for three-phase SSRs, industrial modules and SCR voltage regulators; fan-ready on H and F series.




Selection & mounting
Selection rules
- Match the heatsink to the SSR current rating first, then verify cabinet depth and vertical airflow clearance.
- Above 10 A load current, mount the SSR on an aluminium heatsink with a thin, even film of thermal grease.
- For heavy three-phase or industrial duty (H-110/150, F-120, Y-series) or panel ambient > 40 °C, add an 80×80×30 mm or 90×90×30 mm cooling fan.
3-step mounting
- 1Clean both the heatsink face and the SSR baseplate to bare metal, then apply thermal grease.
- 2Spread a thin, even film across the full contact face — no dry spots, no thick blobs.
- 3Seat the relay flat and tighten the mounting screws alternately so excess grease squeezes out evenly.

Sizing the heatsink
A solid state relay does not lose much voltage, but it passes the whole load current through that loss. A thyristor output drops roughly 1.5 V while it conducts, so the heat to be removed is simply that drop times the current: about 38 W at 25 A, about 90 W at 60 A. The heatsink does not reduce the figure — it only decides how far the relay's base rises above the air in the cabinet.
Work back from the limit rather than from the current rating. A panel-mount SSR is usually rated to 80 °C at its base; in a cabinet sitting at 40 °C that leaves 40 °C of headroom. Divide the headroom by the dissipation and you have the thermal resistance the profile has to beat — about 1.0 °C/W at 25 A, about 0.45 °C/W at 60 A.
Those numbers assume free convection with the fins vertical. A fan blowing across the fins roughly halves the thermal resistance, which is why the wider profiles are drilled for one.
- Mount the relay on a thin, even film of thermal compound. A dry joint adds several °C/W and is the usual reason a heatsink appears not to work.
- Keep the fins vertical and leave clear air above and below them. A heatsink boxed in against a panel wall runs far hotter than its rating.
- The 48 mm hole centres suit single-phase panel-mount SSRs; three-phase blocks bolt through their own footprint.
- A silicone pad is cleaner to fit than compound but adds roughly 0.5 °C/W — fine at low current, not at the top of a profile's range.
- Above about 25 A continuous, or in a sealed cabinet, fit the fan. Forced air is cheaper than the next profile up.
Supply & OEM
Accessory, supplied as a standard part·no printing or logo on this line
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Not offered — supplied as a standard part
- Shipping
- Worldwide export
Frequently asked questions
Which profile should I choose for my SSR?
Choose from the 11 profile families after confirming the SSR baseplate, mounting holes, actual load current, cabinet temperature and cooling arrangement. Confirm thermal suitability for the application before ordering; the SSR nameplate current alone is not a heat sink performance rating.
Do I need the fan?
Not for intermittent or light duty. Above roughly 25 A continuous, or inside a sealed cabinet, the fan is what keeps the relay base under its 80 °C limit — forced air roughly halves the thermal resistance, which is usually cheaper than moving up a profile.
Why does the relay feel hot even on a heatsink?
Because the heatsink spreads heat, it does not absorb it. A 40 A load dissipates around 60 W inside the relay, and the whole assembly will sit tens of degrees above ambient by design. What matters is the base temperature at the relay, not the temperature of the fins.
Can the heatsink be cut or drilled?
Yes — it is an aluminium extrusion, so it can be cut to length, drilled and tapped. Custom cutting, rapid tooling, CNC machining and anodizing are all offered; send the drawing or the length you need.
Related guides
How to Wire TCN4S and TCN4H/L/M Temperature Controllers: Contactor and SSR Methods
Terminal-by-terminal wiring instructions for the TCN4S-14RV and TCN4H/L/M-14RV PID temperature controllers, covering AC contactor (relay output) wiring, BSSR-25DA solid-state…
Read guide Product Updates · 2024-03-18SSR-25DA Solid State Relay: Electrical Data, Sizing, Heat Sink and Wiring
Electrical data, current sizing rules, heat sink and derating guidance, wiring practice and a fault-finding table for the SSR-25DA DC-controlled solid state relay used on…
Read guide Product Updates · 2025-04-04How to Choose a Solid State Relay: Input Type, Current Sizing, Switching Mode and Cooling
A practical selection reference for solid state relays: which input and output combination to specify, how to size load current and voltage including cold inrush, when to use…
Read guideRelated models
All Solid State Relays & SCR Power Modules
SSR-DA Single-Phase SSR — Standard Black Housing, 10A–100A
SE-SSR-DA
SSR-DA Series single-phase solid state relays from Beijing Strong Electric offer fast, silent zero-cross switching for AC resistive loads. Control…
View details
SSR-DA Single-Phase SSR — Standard, 10A–100A
SE-DA
SSR-DA Series Single Phase Solid State Relay switches AC loads from a 3–32VDC control signal. It is built for heating equipment, lighting systems,…
View details
SSR-LA Analog Control SSR — 4–20mA Input, 10A–120A
SE-LA
SSR-LA Series Analog Controlled Solid State Relay is a single-phase solid state voltage regulator module designed for proportional AC load control.…
View details
SSR3 Three Phase Solid State Relay — 10A–200A
SE-SSR3
SSR3 Three Phase Solid State Relay is an industrial-grade three-phase, DC-controlled AC solid state switching module. It accepts a 3–32VDC control…
View detailsNeed help selecting the right model?