Solid State Relays & SCR Power Modules

SSR Heatsink / Aluminum Heat Sink for Solid State Relay

SSR heatsink radiator for solid state relays, with aluminium heat dissipation for 10A-120A SSR modules in heating and automation systems.

SSR heat sink profiles: single-phase and three-phase extruded aluminium bases
SSR Heat Sink: Extruded aluminium alloy.
Material
Extruded aluminium alloy
Construction
Multi-fin extrusion with a flat mounting face
Stock profiles
11 families: I, W, T, Ib, Ic, TH, D, E, H, F and Y; availability confirmed by quotation
Relay mounting
Single-phase panel-mount SSRs fix on 48mm hole centres; three-phase blocks bolt through their own footprint
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

MaterialExtruded aluminium alloy
ConstructionMulti-fin extrusion with a flat mounting face
Stock profiles11 families: I, W, T, Ib, Ic, TH, D, E, H, F and Y; availability confirmed by quotation
Relay mountingSingle-phase panel-mount SSRs fix on 48mm hole centres; three-phase blocks bolt through their own footprint
FinishMill finish as standard; black anodizing to order
Manufacturing OptionsCustom cutting, rapid tooling, CNC machining, anodizing
InstallationScrew-fixed through the channels in the base
Fan MountingCooling fan option on H-110/H-150 (80×80×30mm) and F-120 (90×90×30mm); confirm fan fit per profile
PropertiesCorrosion resistant, wear resistant, heat resistant

Product overview

Part no. SE-HS-SSRindustry model HS-SSR

Also known as: SSR heat sink · heat sink for solid state relay

SSR Heatsink is an aluminium extrusion heat sink for solid state relay modules used in heating, temperature control, motor control, and industrial automation systems. It spreads the heat the relay generates and holds its base down where the module keeps its rating, so the relay survives continuous load instead of derating or failing early. The catalogue is organised into 11 profile families: I, W, T, Ib, Ic, TH, D, E, H, F and Y. Confirm the mounting dimensions and application-specific thermal requirements before ordering.

Key features

  • Extruded aluminium profile with a flat machined face, so the relay base sits on metal rather than on a casting skin
  • 11 profile families for single-phase, DIN-rail and three-phase applications; confirm mechanical fit and thermal requirements
  • Single-phase profiles use the standard panel-mount hole centres, so a standard SSR drops straight on
  • Drilled for a side fan; the fan size follows the profile width
  • Screw channels run the length of the base, so the assembly fixes down without a separate nut
  • Recommended for SSR loads above 10A, where a bare relay would derate or fail early
  • Cut to length, drilled, tapped and anodized to order
  • Suitable for heating equipment, control cabinets and machine panels

Works with

The parts that go into the same panel and are usually ordered with it.

Heat sink sizing by relay current

An SSR drops about 1.6 V whatever the load, so the heat it makes is the current times that drop: 40 A is roughly 64 W inside a box the size of a matchbox. The relay's rating only holds with a sink under it, and the sink has to be at or below the thermal resistance in this table.

Relay currentHeat in the relayHeat sink at or belowMounting
10 A16 W≤ 5.0 °C/WPlate 80 × 50 mm
15 A24 W≤ 3.0 °C/WPlate 100 × 60 mm
25 A40 W≤ 2.0 °C/WFinned 100 × 80 mm
40 A64 W≤ 1.2 °C/WFinned 120 × 100 mm
60 A96 W≤ 0.8 °C/WFinned 150 × 120 mm, fan assisted
80 A128 W≤ 0.6 °C/WFinned 200 × 120 mm, fan assisted
100 A160 W≤ 0.45 °C/WFinned 250 × 120 mm, forced air

Figures assume an ambient of 40 °C, a junction limit of 125 °C and thermal paste between relay and sink. Above 40 °C ambient, derate the current by about 1 % per °C, or fit the next size of sink. A relay mounted without a sink carries a fraction of its rating.

11 heatsink profile families (single-phase, DIN rail & three-phase)

Pick your group below — each card shows the extruded profile, cross-section dimensions (mm), rated SSR current and fan/DIN-rail options.

Single-phase panel mount (≤ 15 A – 80 A)

Standard extruded blocks for single-phase SSR-DA / AA / LA modules.

TYPE I (I-50) SSR heatsink dimensions
I-50 · 50×60×50 mm · Single-phase SSR ≤ 15 A
TYPE W (W-70 / W-100 / W-110) SSR heatsink dimensions
W-70 (≤ 40 A) · W-100 / W-110 (≤ 60 A)
TYPE T (T-80 / T-110) SSR heatsink dimensions
T-80 (≤ 60 A) · T-110 (≤ 80 A) · Optional DIN base
TYPE Ib SSR heatsink dimensions
Ib · 49×74×80 mm · Single-phase SSR ≤ 80 A
TYPE Ic SSR heatsink dimensions
Ic · 50×86×96 mm · Single-phase SSR ≤ 60 A

TS35 DIN-rail mount (≤ 40 A)

Factory-fitted with a TS35 DIN-rail clip for compact control cabinets.

TYPE TH (TH-76) SSR heatsink dimensions
TH-76 · 76×44×72 mm · TS35 DIN rail · ≤ 40 A
TYPE D (D-74) SSR heatsink dimensions
D-74 · 74×48×55 mm · TS35 DIN rail · ≤ 40 A

Three-phase & industrial high-current (40 A – 250 A)

Heavy-duty blocks for three-phase SSRs, industrial modules and SCR voltage regulators; fan-ready on H and F series.

TYPE E (E-52 / E-105 / E-130) SSR heatsink dimensions
E-52 / E-105 / E-130 · 40 mm low-profile · 3-ph ≤ 80 A / 1-ph ≤ 120 A
TYPE H (H-110 / H-150) SSR heatsink dimensions
H-110 (≤ 60 A) · H-150 (≤ 80 A) · Fits 80×80×30 mm fan
TYPE F (F-120) SSR heatsink dimensions
F-120 · 3-ph ≤ 100 A / Ind. ≤ 120 A · Fits 90×90×30 mm fan
TYPE Y (Y-80 / Y-110 / Y-150) SSR heatsink dimensions
Y-80 / Y-110 / Y-150 · 3-ph ≤ 200 A / Industrial ≤ 250 A · 200/300/350 mm available

Selection & mounting

Selection rules

  • Match the heatsink to the SSR current rating first, then verify cabinet depth and vertical airflow clearance.
  • Above 10 A load current, mount the SSR on an aluminium heatsink with a thin, even film of thermal grease.
  • For heavy three-phase or industrial duty (H-110/150, F-120, Y-series) or panel ambient > 40 °C, add an 80×80×30 mm or 90×90×30 mm cooling fan.

3-step mounting

  1. 1Clean both the heatsink face and the SSR baseplate to bare metal, then apply thermal grease.
  2. 2Spread a thin, even film across the full contact face — no dry spots, no thick blobs.
  3. 3Seat the relay flat and tighten the mounting screws alternately so excess grease squeezes out evenly.
Fitting a solid state relay to the heatsink in three steps

Sizing the heatsink

A solid state relay does not lose much voltage, but it passes the whole load current through that loss. A thyristor output drops roughly 1.5 V while it conducts, so the heat to be removed is simply that drop times the current: about 38 W at 25 A, about 90 W at 60 A. The heatsink does not reduce the figure — it only decides how far the relay's base rises above the air in the cabinet.

Work back from the limit rather than from the current rating. A panel-mount SSR is usually rated to 80 °C at its base; in a cabinet sitting at 40 °C that leaves 40 °C of headroom. Divide the headroom by the dissipation and you have the thermal resistance the profile has to beat — about 1.0 °C/W at 25 A, about 0.45 °C/W at 60 A.

Those numbers assume free convection with the fins vertical. A fan blowing across the fins roughly halves the thermal resistance, which is why the wider profiles are drilled for one.

  • Mount the relay on a thin, even film of thermal compound. A dry joint adds several °C/W and is the usual reason a heatsink appears not to work.
  • Keep the fins vertical and leave clear air above and below them. A heatsink boxed in against a panel wall runs far hotter than its rating.
  • The 48 mm hole centres suit single-phase panel-mount SSRs; three-phase blocks bolt through their own footprint.
  • A silicone pad is cleaner to fit than compound but adds roughly 0.5 °C/W — fine at low current, not at the top of a profile's range.
  • Above about 25 A continuous, or in a sealed cabinet, fit the fan. Forced air is cheaper than the next profile up.

Supply & OEM

Accessory, supplied as a standard part·no printing or logo on this line

Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Not offered — supplied as a standard part
Shipping
Worldwide export

Frequently asked questions

Which profile should I choose for my SSR?

Choose from the 11 profile families after confirming the SSR baseplate, mounting holes, actual load current, cabinet temperature and cooling arrangement. Confirm thermal suitability for the application before ordering; the SSR nameplate current alone is not a heat sink performance rating.

Do I need the fan?

Not for intermittent or light duty. Above roughly 25 A continuous, or inside a sealed cabinet, the fan is what keeps the relay base under its 80 °C limit — forced air roughly halves the thermal resistance, which is usually cheaper than moving up a profile.

Why does the relay feel hot even on a heatsink?

Because the heatsink spreads heat, it does not absorb it. A 40 A load dissipates around 60 W inside the relay, and the whole assembly will sit tens of degrees above ambient by design. What matters is the base temperature at the relay, not the temperature of the fins.

Can the heatsink be cut or drilled?

Yes — it is an aluminium extrusion, so it can be cut to length, drilled and tapped. Custom cutting, rapid tooling, CNC machining and anodizing are all offered; send the drawing or the length you need.

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.