SSR-LA Analog Controlled Solid State Relay, 4–20mA Input, 10A–100A

SSR-LA Series Analog Controlled Solid State Relay is a single-phase solid state voltage regulator module designed for proportional AC load control. It accepts a standard 4–20mA analog input signal and adjusts the AC output voltage accordingly, making it suitable for heating systems, temperature control equipment, fans, packaging machines and industrial automation applications.
The SSR-LA series is available in 10A, 25A, 40A, 60A, 80A and 100A current ratings, with an output voltage range of 0–2

SSR-LA Analog Controlled Solid State Relay, 4–20mA Input, 10A–100A

Select the number of specifications

Please check the product information you want!

Key Features Technical Specifications Applications FAQ

  • 4–20mA analog input control
  • Proportional AC voltage output
  • Single-phase solid state voltage regulation
  • Output voltage range: 0–250VAC
  • Available current ratings: 10A to 100A
  • Opto-isolated internal circuit design
  • High dielectric strength over 4KV
  • High isolation resistance over 100MΩ / 500VDC
  • High surge current and surge voltage resistance
  • Suitable for heating and automation control systems

ItemSpecification
Product SeriesSSR-LA Series
Product TypeAnalog Controlled Solid State Relay
Control Signal4–20mA
Output TypeProportional AC Voltage Output
Output Voltage Range0–250VAC
Rated Current10A / 25A / 40A / 60A / 80A / 100A
Output Voltage Range Ratio7%–95%
Peak Voltage600VAC
On-State Voltage Drop≤5.6V
Off-State Leakage Current≤8mA rms
Dielectric Strength4000Vrms
Isolation Resistance≥100MΩ / 500VDC
Ambient Temperature-20°C to +75°C
Mounting MethodScrew Mount
CertificationCE


  • Electric heating control
  • Temperature control systems
  • Industrial ovens
  • Packaging machinery
  • Drying equipment
  • Plastic machinery
  • Fan speed control
  • HVAC equipment
  • Automation control cabinets
  • Resistive load voltage regulation

Q1: What is the difference between SSR-LA and SSR-DA?
SSR-DA is mainly used for ON/OFF switching, while SSR-LA accepts a 4–20mA analog signal and provides proportional AC voltage output.

Q2: What input signal does SSR-LA support?
SSR-LA supports standard 4–20mA analog current input.

Q3: What output voltage does SSR-LA provide?
The SSR-LA series provides proportional AC output with a voltage range of 0–250VAC.

Q4: What current ratings are available?
Available models include 10A, 25A, 40A, 60A, 80A and 100A.

Q5: Does SSR-LA need a heatsink?
Yes. A suitable heatsink is recommended, especially when the load current is high or the module works continuously.


No comment

Key Features
  • 4–20mA analog input control
  • Proportional AC voltage output
  • Single-phase solid state voltage regulation
  • Output voltage range: 0–250VAC
  • Available current ratings: 10A to 100A
  • Opto-isolated internal circuit design
  • High dielectric strength over 4KV
  • High isolation resistance over 100MΩ / 500VDC
  • High surge current and surge voltage resistance
  • Suitable for heating and automation control systems

Technical Specifications
ItemSpecification
Product SeriesSSR-LA Series
Product TypeAnalog Controlled Solid State Relay
Control Signal4–20mA
Output TypeProportional AC Voltage Output
Output Voltage Range0–250VAC
Rated Current10A / 25A / 40A / 60A / 80A / 100A
Output Voltage Range Ratio7%–95%
Peak Voltage600VAC
On-State Voltage Drop≤5.6V
Off-State Leakage Current≤8mA rms
Dielectric Strength4000Vrms
Isolation Resistance≥100MΩ / 500VDC
Ambient Temperature-20°C to +75°C
Mounting MethodScrew Mount
CertificationCE


Applications
  • Electric heating control
  • Temperature control systems
  • Industrial ovens
  • Packaging machinery
  • Drying equipment
  • Plastic machinery
  • Fan speed control
  • HVAC equipment
  • Automation control cabinets
  • Resistive load voltage regulation

FAQ

Q1: What is the difference between SSR-LA and SSR-DA?
SSR-DA is mainly used for ON/OFF switching, while SSR-LA accepts a 4–20mA analog signal and provides proportional AC voltage output.

Q2: What input signal does SSR-LA support?
SSR-LA supports standard 4–20mA analog current input.

Q3: What output voltage does SSR-LA provide?
The SSR-LA series provides proportional AC output with a voltage range of 0–250VAC.

Q4: What current ratings are available?
Available models include 10A, 25A, 40A, 60A, 80A and 100A.

Q5: Does SSR-LA need a heatsink?
Yes. A suitable heatsink is recommended, especially when the load current is high or the module works continuously.


SSR-LA Analog Controlled Solid State Relay, 4–20mA Input, 10A–100A
SSR-LA Series Analog Controlled Solid State Relay is a single-phase solid state voltage regulator module designed for proportional AC load control. It accepts a standard 4–20mA analog input signal and adjusts the AC output voltage accordingly, making it suitable for heating systems, temperature control equipment, fans, packaging machines and industrial automation applications.
The SSR-LA series is available in 10A, 25A, 40A, 60A, 80A and 100A current ratings, with an output voltage range of 0–2
Long press to look detail
Long by picture save/share
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully

SSR-LA Analog Controlled Solid State Relay, 4–20mA Input, 10A–100A

Enquiry
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully

Follow Us

Follow Us

Copyright © 2005-2025 Beijing Strong Electric Co., Ltd. All Rights Reserved.

Service Center

Please choose online customer service to communicate

Contacts
Scan a QR Code
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了