Insulation Monitors

UBCH2 Dual-Channel DC Insulation Monitoring Device

Dual-channel DC insulation monitoring device watching two circuits from one unit, with the face, setting and response of this version in the table below.

SZDCG-UBCH2 dual-channel DC insulation monitoring device, front view
UBCH2: EV1 and EV2 strips, each with DC+ and DC−, a common alarm and the RS485 pair.
DC system voltage measured
0–1000 VDC
DC measurement accuracy
±2 V from 0 to 400 VDC, ±0.5 % from 400 to 1000 VDC
Vehicle-side voltage range
0–1000 VDC
Vehicle-side accuracy
±2 V from 0 to 400 VDC, ±0.5 % from 400 to 1000 VDC
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

ProductDC insulation monitor for unearthed systems
DC system voltage measured0–1000 VDC
DC measurement accuracy±2 V from 0 to 400 VDC, ±0.5 % from 400 to 1000 VDC
Vehicle-side voltage range0–1000 VDC
Vehicle-side accuracy±2 V from 0 to 400 VDC, ±0.5 % from 400 to 1000 VDC
Auxiliary supply10–30 VDC, ≤6 W
Insulation resistance range0 kΩ–10 MΩ across a 100–1000 VDC system
Insulation accuracy, Cy² 0–0.8 µF≤60 kΩ: ≤3 kΩ · 60 kΩ–1 MΩ: ≤5 %
Insulation accuracy, Cy² 0.8–3 µF≤60 kΩ: ≤6 kΩ · 60 kΩ–1 MΩ: ≤20 %
First reading after switch-on0.7–2.5 s
Reading refresh after a change0.5–3 s
Function switch operations20 × 10⁵
Storage / working temperature−55 to 90 °C / −40 to 75 °C

Product overview

Part no. SE-UBCH2

Also known as: UBCH2 insulation monitor

One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it is the cut-out it needs.

Key features

  • The face, the setting and the response of this version, listed in its own table
  • One version per page, because these differ between them
  • Photograph and drawing where the factory has supplied one

Works with

The parts that go into the same panel and are usually ordered with it.

Dimensions

Dimensional drawing of the insulation monitor
UBCH2 boxed outline: the same case as the UBCH1, with a strip for each channel.

Supply & OEM

Available with your logoMOQ 5 units·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.