Insulation Monitors
SZDCG-UBCS1-250 DC Insulation Monitor for Battery Systems
The battery-system version of the DIN-rail family: same case, same pluggable terminals at one pitch, and a response range that stops a decade earlier.

- DC system voltage measured
- 0–250 VDC
- Measurement accuracy
- ≤2 V +0.3 % across 50–250 VDC
- Auxiliary supply
- 10–30 VDC; 110 mA at 12 V or 60 mA at 24 V, ≤1.5 W
- Insulation resistance range
- 0 kΩ–1 MΩ across a 50–250 VDC system
Technical specifications
| Product | DC insulation monitor for unearthed systems |
|---|---|
| DC system voltage measured | 0–250 VDC |
| Measurement accuracy | ≤2 V +0.3 % across 50–250 VDC |
| Auxiliary supply | 10–30 VDC; 110 mA at 12 V or 60 mA at 24 V, ≤1.5 W |
| Insulation resistance range | 0 kΩ–1 MΩ across a 50–250 VDC system |
| Insulation accuracy at 50–125 V | 1 kΩ–200 kΩ: ≤3 kΩ · 200–500 kΩ: ≤10 % · 500 kΩ–1 MΩ: ≤20 % |
| Insulation accuracy at 125–250 V | 1 kΩ–200 kΩ: ≤3 kΩ · 200–500 kΩ: ≤5 % · 500 kΩ–1 MΩ: ≤10 % |
| With Cy² > 0.3 µF and Riso > 1 MΩ | >10 % |
| First reading / refresh | 0.7–2.5 s / 0.5–3 s |
| Earth-switch operations | 50 × 10⁵ |
| Storage / working temperature | −55 to 90 °C / −40 to 75 °C |
Product overview
Part no. SE-UBCS1-250industry model UBCS1-250
Also known as: SZDCG-UBCS1-250 insulation monitor
The battery-system version of the DIN-rail family, for the voltages a stationary battery runs at: same case, same pluggable terminals at the same pitch, and a response range that stops a decade earlier because the bus it watches never needs more.
Key features
- For stationary battery systems, not a kilovolt bus
- Accuracy stated per resistance band in the table
- Same DIN case and terminal pitch as the rest of the family
- First reading and refresh times given for a step change
Works with
The parts that go into the same panel and are usually ordered with it.
Dimensions

Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All Insulation Monitors
UBCS1 DIN-Rail DC Insulation Monitor
SE-UBCS1
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View details
SZDCG-UBCS1-60 DC Insulation Monitor for Control Circuits
SE-UBCS1-60
The control-circuit version: the low voltages a panel's own rail lives at. Same DIN case and the same terminals as the rest of the family, so a panel…
View details
UBC1 DC Insulation Monitor for Charging Posts
SE-UBC1
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View details
UBCH1 Boxed DC Insulation Monitoring Device
SE-UBCH1
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.