Temperature Controllers
XMT M / MS Single-Display Temperature Controller
Single-display panel temperature controllers in four sizes — 48×48, 48×96, 72×72 and 96×96 mm — with Mode, up and down keys and upper and lower limit lamps.

- Models
- XMTG, XMTE, XMTD and XMTA, each in an M relay build, an S SSR build, or an MS build with the alarm relay added
- Panel sizes
- 48×48, 48×96, 72×72 and 96×96 mm
- Panel cutouts
- 45×45, 45×92, 68×68 and 92×92 mm
- Supply
- 220 VAC or 380 VAC
Technical specifications
| Series | XMT M / MS single-display temperature controller |
|---|---|
| Models | XMTG, XMTE, XMTD and XMTA, each in an M relay build, an S SSR build, or an MS build with the alarm relay added |
| Panel sizes | 48×48, 48×96, 72×72 and 96×96 mm |
| Panel cutouts | 45×45, 45×92, 68×68 and 92×92 mm |
| Supply | 220 VAC or 380 VAC |
| Accuracy | ±1 °C |
| Measuring range | 0–400 °C |
| Display | One four-digit display, large enough to read across a shop floor |
| Front keys | Mode, up and down |
| Indicator lamps | Upper-limit, measured-value and lower-limit legends beside the display, plus ON/OFF lamps showing the output state |
| What the front does | The display shows the measurement. The mode key steps between the alarm limit and the output limit, the two arrows set whichever is showing, and the lamp beside each says which one that is |
| Mounting | Panel mount with the snap-in clips on the case sides |
Product overview
Part no. SE-XMT-MSindustry model XMT-MS
Also known as: XMT-M single-display temperature controller · XMT-MS temperature controller
One big display and three keys. The measurement fills the front, the mode key steps between the alarm limit and the output limit, and a lamp beside each tells the operator which one is on show. It is the controller for a machine where someone walks up, reads a number and turns a limit — not for one that needs a menu.
Key features
- Four bezels: 48×48, 48×96, 72×72 and 96×96 mm
- One four-digit display, large enough to read across a shop floor
- Mode, up and down keys across the bottom
- Upper-limit, measured-value and lower-limit legends beside the display, plus ON/OFF lamps showing the output state
- The codes after the size name the output version, the input and the alarm; the ordering table for each size lists the relay, SSR drive and alarm combinations available for that size
- 0–400 °C range, ±1 °C accuracy, 220 VAC or 380 VAC supply
- Panel cutouts 45×45, 45×92, 68×68 and 92×92 mm
Works with
The parts that go into the same panel and are usually ordered with it.
Ordering & Selection Guide
XMT + bezel letter (64mm depth) + output letters (M relay, S SSR, MS relay + alarm) + supply voltage (220 or 380 VAC).
Bezel letters (64mm depth)
- G
- 48×48mm · cut-out 45×45
- E
- 48×96mm · cut-out 45×92
- D
- 72×72mm · cut-out 68×68
- A
- 96×96mm · cut-out 92×92
Output letters
- M
- Relay contact output
- S
- SSR drive output (external SSR)
- MS
- Relay output + alarm relay
Supply digits
- 220
- 220 VAC standard supply
- 380
- 380 VAC three-phase panel supply
Worked example
XMTD-MS220
XMTD-MS220: 72×72mm front, relay + alarm relay, 220 VAC supply (use 380 for three-phase panel).
Documents for this family
- XMT-1000 series wiring207 KB · 2026-11-19
- XMT-6000 (6311 / 6511) wiring325 KB · 2026-11-18
- XMT-8000 series wiring308 KB · 2026-11-18
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 3 years
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related guides
TEL96-9001 or TEL96-2001: Choosing the Right Oven Temperature Controller
The TEL96 series is a 96 x 96 mm on/off oven temperature controller built around a K-type thermocouple input and a 10 A relay contact. It is made in two versions, the TEL96-9001…
Read guide FAQ · 2025-06-17TCN4 PT100 Decimal Display and Hysteresis Setting Guide
Step-by-step guide to enabling PT100 1-digit decimal display and setting hysteresis (HYS) on the TCN4 temperature controller for stable ON/OFF control.
Read guide Technical Guides · 2025-05-31TC5 Setup Guide: PT100 Input, Decimal Display and 45–50°C Range Control
Setup guide for the TC5 series temperature controller, covering PT100 input selection, decimal display resolution and 45–50°C hysteresis range control.
Read guideRelated models
All Temperature Controllers
6311 Series Digital Temperature Controllers (XMTG / XMTE / XMTD / XMTA fronts)
SE-XMT-6311
The XMT-6311 is the four-bezel member of the XMT-6000 family, and the only one here that reaches the large strip format. One body is built as…
View details
8411 Series PID Temperature Controllers (XMTG / XMTE / XMTD / XMTA fronts)
SE-XMT-8411
The 8000 series is the smaller series' body with a wider instrument behind the bezel: one input that takes the whole thermocouple and RTD range, a…
View details
XMT-1000 Series Digital Temperature Controller
SE-XMT-1000
The measured value on the display, the setpoint on a three-digit thumbwheel switch underneath. No menu, no key sequence: whoever is standing at the…
View details
XMTD Series Digital Temperature Controller
SE-XMTD
The XMTD-2001 and XMTD-2201 are 72×72 mm panel-mount On/Off temperature controllers built for straightforward, menu-free operation. Operators set the…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.