Temperature Controllers

XMT-1000 Series Digital Temperature Controller

Thumbwheel-set temperature controllers in four bezels, K or E thermocouple input over 0–999 °C across the stocked builds, ±1.0 %FS accuracy and a dry relay contact.

XMTG-1001, XMTE-1001, XMTD-1001 and XMTA-1001 thumbwheel temperature controllers
XMTA-1001 at the left, then XMTE, XMTD and XMTG: the same wheel under every display.
Output
Relay output, a dry (voltage-free) contact
Input
K or E thermocouple
Models
XMTG-1001, XMTE-1001, XMTD-1001 and XMTA-1001
Panel sizes
48×48×82, 48×96×107, 72×72×65 and 96×96×73 mm
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesXMT-1000, thumbwheel setpoint
ModelsXMTG-1001, XMTE-1001, XMTD-1001 and XMTA-1001
Panel sizes48×48×82, 48×96×107, 72×72×65 and 96×96×73 mm
Panel cutouts45×45, 45×92, 68×68 and 92×92 mm
Supply220 VAC 50/60 Hz
Accuracy±1.0 %FS
Range0–999 °C across the stocked builds
InputK or E thermocouple
Setpointthree-digit thumbwheel under the display
Control methodTwo-position (on/off) control with a fixed 2 °C differential
OutputRelay output, a dry (voltage-free) contact
Contact rating250 V 3 A
Operating environment0–50 °C, 30–85 %RH, no corrosive gas
Front protectionIP44
Response timeone second
MountingPanel mount, snap-in clips
Typical useOvens, incubators, packaging sealers, small heaters and other single-loop machines

Product overview

Part no. SE-XMT-1000

Also known as: XMT-1000 temperature controller · XMT-1000 On/Off temperature controller

The measured value on the display, the setpoint on a three-digit thumbwheel switch underneath. No menu, no key sequence: whoever is standing at the machine adjusts the thumbwheel and the heat changes. Four bezels, with the output options and contact rating of each build given on its sheet.

Key features

  • XMTG-1001, XMTE-1001, XMTD-1001 and XMTA-1001
  • Panels 48×48×82, 48×96×107, 72×72×65 and 96×96×73 mm, cut-outs 45×45, 45×92, 68×68 and 92×92 mm
  • K or E thermocouple input, 0–999 °C across the stocked builds
  • ±1.0 %FS accuracy, 220 VAC 50/60 Hz supply
  • Relay output, dry contact rated 250 V 3 A

Works with

The parts that go into the same panel and are usually ordered with it.

Four bezels

The 1000 series is the thumbwheel-set half of the XMT family: the measured value is on the display and the setpoint is on the three-digit wheel under it, so nobody has to walk a menu to change the heat.

ModelPanel (mm)Cutout (mm)
XMTG-100148 × 48 × 8245 × 45
XMTE-100148 × 96 × 10745 × 92
XMTD-100172 × 72 × 6568 × 68
XMTA-100196 × 96 × 7392 × 92

Ordering & Selection Guide

XMT, the bezel letter, a dash, the series figure 1, then the control mode, the alarm count and the input. The 1 is fixed and carries no position number.

XMTA①-1series0②1③1④

① · Panel size

G48×48×82, cut-out 45×45
E48×96×107, cut-out 45×92
D72×72×65, cut-out 68×68
A96×96×73, cut-out 92×92

② · Control mode

0Two-position control (on/off)
2Three-position control
3Time-proportioning control

③ · Alarm output

0No alarm output
1One alarm relay (ALM1)
2Two alarm relays (ALM1 and ALM2)

④ · Input type

1Thermocouple — K or E
2RTD — Pt100 or Cu50

Worked example

XMTA-1011

A 96 square unit with two-position control, one alarm relay and a thermocouple input. Change the third digit to a 2 and it takes an RTD; a 3 in the control position selects time proportioning.

How it differs from the 2000 series

Same wheel, same front layout, different case depths and a different code: the 2000 series reads XMT D - 2 ..., this one reads XMT D - 1 .... Both take the same lead colours and the same 250 V 3 A contact, so a panel does not care which is fitted.

Input codes and measuring ranges

Most orders use K02 (K 0–400 °C), K06 (K 0–1200 °C), D10 (Pt100 0–500 °C) or 801 (4–20 mA). Expand the full table below for all 14 sensor types and range codes.

③ Full input code table (14 sensor types: K, J, R, S, B, E, N, T, Pt100, Cu50 & 4–20 mA)
InputCode and measuring range
KThermocouple
K01 0–200 °CK02 0–400 °CK03 0–600 °CK04 0–800 °CK05 0–1000 °CK06 0–1200 °CK07 0–1372 °CK13 0–100 °CK14 0–300 °C
JThermocouple
J01 0–200 °CJ02 0–400 °CJ03 0–600 °CJ04 0–800 °CJ05 0–100 °CJ06 0–1200 °C
RThermocouple (accuracy not guaranteed over 0–399 °C)
R01 0–1600 °CR02 0–1769 °CR03 0–1350 °C
SThermocouple (accuracy not guaranteed over 0–399 °C)
S01 0–1600 °CS02 0–1769 °C
BThermocouple (accuracy not guaranteed over 0–399 °C)
B01 400–1800 °CB02 0–1769 °C
EThermocouple
E01 0–800 °CE02 0–1000 °C
NThermocouple
N01 1–1300 °CN02 0–1300 °C
TThermocouple (accuracy held from −199 to 100 °C)
T01 −199.9–400.0 °CT02 −199.9–100.0 °CT03 −199.9–200.0 °CT04 0–350.0 °C
PT100RTD
D01 −199.9–649.0 °CD02 −199.9–200.0 °CD03 −100–50 °CD04 −100–100 °CD05 −100–200 °CD06 0.0–50.0 °CD07 0.0–100 °CD08 0.0–200 °CD09 0.0–300 °CD10 0.0–500 °C
Cu50RTD
P01 −50.0–150.0 °CP02 0.0–150.0 °CP03 0.0–100.0 °CP04 −50.0–0.0 °CP05 −50.0–100.0 °CP06 −50.0–50.0 °CP07 −50–150 °CP08 0–150 °CP09 0–100 °CP10 0–50 °C
0–5VDCStandard signal
401 0.0–100.0
1–5VDCStandard signal
601 0.0–100.0
0–20mAStandard signal, 250 Ω resistor across the terminals
701 0.0–100.0
4–20mAStandard signal, 250 Ω resistor across the terminals
801 0.0–100.0

Linear inputs scale over 0.0–100.0 in engineering units; 0–20 mA and 4–20 mA require a 250 Ω shunt resistor across the terminals.

Alarm type codes

The alarm position in the model code is a letter, not a number. These are the twelve codes the REX, CH and XMT families accept, in the order the factory sheets print them, so a code read off one sheet means the same thing on the next.

CodeAlarm type
NNo alarm
ADeviation high (upper)
BDeviation low (lower)
CDeviation high and low
DBand (deviation range)
EDeviation high, hold action
FDeviation low, hold action
GDeviation high and low, hold action
HProcess high (absolute)
JProcess low (absolute)
KProcess high, hold action
LProcess low, hold action

Codes E, F and G behave like A, B and C but stay latched after the condition clears, until the operator resets the instrument. K and L do the same for the absolute limits.

Codes H, J, K and L compare against an absolute temperature instead of an offset from the set point.

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

Wiring

Two bodies, two terminal layouts, one sheet: the XMTG-1001 with twelve terminals and the XMTE-1001 with eight, each on a contactor with its electrician's diagram beside it. The 220 V and 380 V versions of either are wired the same way — only the transformer inside differs.

XMTG-1001 / XMTE-1001 · wiring and electrician's diagrams

XMTG-1001 / XMTE-1001 · wiring and electrician's diagrams

Read the panel for the body you have: the two blocks here are numbered differently, and the jumper moves with them — 2–5 on the XMTG body, 5–8 on the XMTE. Thermocouple polarity follows the block too: red to 12 and blue to 11 on one, red to 1 and blue to 2 on the other.

Download the sheet (PDF)

Documents for this family

All documents

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.