BT6 Series Intelligent PID Temperature Controller with Timer and RS485 Modbus

BT6 panel-mount PID temperature controller with a built-in 0–9999 timer and universal TC, RTD or linear input, 4–20 mA retransmission.

BT6 temperature controller, two-row LED display for PV and SV, 48×48 / 48×96 / 72×72 / 96×96mm
BT6: Two-row LED display for PV and SV; 48×48 / 48×96 / 72×72 / 96×96mm; Thermocouple K, J, R, S, B, E, N, T.
Panel size
48×48 / 48×96 / 72×72 / 96×96mm
Panel cutout
46×46 / 45×91 / 67×67 / 91×91mm
Supply voltage
100–240VAC, 50Hz
Input
Thermocouple K, J, R, S, B, E, N, T; RTD PT100 and CU50; linear 0–50mV, 0–5V, 1–5V
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Ordering & Selection Guide

The same code, broken into its positions: what each character fixes, and which values this family actually uses.

BT6Series
-BSize
KInput
1220Output and alarms
RS485Communications
PositionValueWhat it selectsSold as
SeriesBT6The BT6 series of panel-mount PID temperature controllersBT6-AK1220 →BT6-AK320 →BT6-AK1620 →BT6-AK120 RS485 →+22 more, see the table above
SizeA48 × 48 bezel on a 46 × 46 mm cut-outBT6-AK1220 →BT6-AK320 →BT6-AK1620 →BT6-AK120 RS485 →+4 more, see the table above
B48 × 96 bezel on a 45 × 91 mm cut-outBT6-BK1220 →BT6-BK320 →BT6-BK1620 →BT6-BK1220 RS485 →+2 more, see the table above
D72 × 72 bezel on a 67 × 67 mm cut-outBT6-DK1220 →BT6-DK320 →BT6-DK1620 →BT6-DK1220 RS485 →+2 more, see the table above
E96 × 96 bezel on a 91 × 91 mm cut-outBT6-EK1220 →BT6-EK320 →BT6-EK1620 →BT6-EK1220 RS485 →+2 more, see the table above
InputKK thermocouple input. The manual's code table lists J, R, S, B, E, N, T, Pt100, Cu50 and the linear ranges as the other choices; the listing sells the K versionBT6-AK1220 →BT6-AK320 →BT6-AK1620 →BT6-AK120 RS485 →+22 more, see the table above
Output and alarms120Relay contact output with the RS485 board, one high-deviation alarmOutput 1 (relay) and alarm pair 20: one high-deviation alarm on AL1, AL2 unusedBT6-AK120 RS485 →
124Relay contact output, two alarms (high and low deviation)Output 1 (relay) and alarm pair 24: high and low deviation, the two alarms the listing labels as suchBT6-AK124 →
220Solid-state (SSR) drive with the RS485 board, one high-deviation alarmOutput 2 (solid state) and alarm pair 20: one high-deviation alarm on AL1BT6-AK220 RS485 →
224Solid-state (SSR) drive, two alarms (high and low deviation)Output 2 (solid state) and alarm pair 24: high and low deviationBT6-AK224 →
320PID 4–20 mA control output, one high-deviation alarmOutput 3 (PID 4–20 mA) and alarm pair 20: one high-deviation alarm. The listing prints the RS485 rows of this block without the input letter (BT6-A 320 RS485); it is the same instrumentBT6-AK320 →BT6-AK320 RS485 →BT6-BK320 →BT6-BK320 RS485 →+4 more, see the table above
1220Relay contact plus solid-state (SSR) drive, one high-deviation alarmOutputs 1 and 2 (relay plus solid state) and alarm pair 20: one high-deviation alarmBT6-AK1220 →BT6-BK1220 →BT6-BK1220 RS485 →BT6-DK1220 →+3 more, see the table above
1224Relay contact plus solid-state (SSR) drive, two alarms (high and low deviation)Outputs 1 and 2 (relay plus solid state) and alarm pair 24: high and low deviationBT6-BK1224 →BT6-DK1224 →BT6-EK1224 →
1620Relay contact plus 4–20 mA retransmission output, one high-deviation alarmOutputs 1 and 6 (relay plus 4–20 mA retransmission) and alarm pair 20: one high-deviation alarmBT6-AK1620 →BT6-BK1620 →BT6-DK1620 →BT6-EK1620 →
Output digits, the block before the alarm pair
1Relay output, built in
2Logic-level output driving an external solid state relay
3PID 4–20 mA current output (custom build)
4SCR phase-angle or zero-crossing triggering (custom build)
530 A relay (custom build)
64–20 mA retransmission of the measured value (custom build)

Digits 1 and 2 are the two stages the factory builds as standard, which is why the listing sells almost nothing else. A two-digit block is two outputs fitted together: 12 is the relay and the logic-level output on one instrument.

Alarm digits, the last two characters
0No alarm; the AL1 and AL2 menus stay hidden
1High absolute alarm
2High deviation alarm, the AL1 default
3Low absolute alarm, the AL2 default
4Low deviation alarm
5Outside-band alarm
6Inside-band alarm
P1–P4The four digits above with power-on hold: the alarm stays inhibited until the instrument has been powered for the configured time

The supplier's 型号定义 sheet prints digit 2 as 下限偏差报警 and then prints 下限偏差报警 again for digit 4. The manual's A4 table and its alarm-mode list both put high deviation at 2 and low deviation at 4, and the rows the listing marks as two alarms carry 24 — which only reads as high plus low that way. This page follows the manual.

Technical specifications

SeriesBT6 Series (panel-mount PID temperature controller with timer)
ModelsBT6-A / BT6-B / BT6-D / BT6-E
DisplayTwo-row LED display for PV and SV
Control methodPID with auto-tuning; P = 0 selects ON/OFF control with an adjustable switching differential
Timer0–9999s or minutes, set independently of the control loop
InputThermocouple K, J, R, S, B, E, N, T; RTD PT100 and CU50; linear 0–50mV, 0–5V, 1–5V
Main outputRelay, logic-level SSR drive, 4–20mA control or 4–20mA retransmission, by order code
Alarm outputUp to 2 alarms; modes 0–6 and P1–P4 (11 modes)
CommunicationRS485 Modbus, optional
Supply voltage100–240VAC, 50Hz
Power consumption≤ 5VA
Accuracy±0.5 °C
Display resolution1°C or 0.1°C, selectable
Panel size48×48 / 48×96 / 72×72 / 96×96mm
Case depth83mm for all four sizes
Panel cutout46×46 / 45×91 / 67×67 / 91×91mm
Terminal torque0.74–0.90N·m
Warranty3 years

Product overview

Part no. SE-BT6

Also known as: BT6 temperature controller · BT6 PID controller · BT6 controlador de temperatura

BT6 Series is a panel-mount PID temperature controller for equipment builders who need a timed heating cycle and a retransmission signal in the same instrument. It accepts thermocouple, RTD and linear input, drives a relay or an external solid state relay, carries up to two alarm outputs, and offers an optional RS485 Modbus port — in four panel sizes sharing one 83 mm case depth.

Key features

  • Built-in timer, 0–9999 s or minutes, set independently of the control loop
  • Universal input: thermocouple K, J, R, S, B, E, N, T; RTD PT100 and CU50; linear 0–50 mV, 0–5 V, 1–5 V
  • PID with auto-tuning; P = 0 switches the instrument to ON/OFF control with an adjustable differential
  • Main output selectable as relay, logic-level SSR drive, 4–20 mA control or 4–20 mA retransmission
  • Up to two alarm outputs with eleven selectable modes, including absolute, deviation, band and power-on hold
  • Optional RS485 Modbus for PLC, HMI and data logger integration
  • Four panel sizes — 48×48 / 48×96 / 72×72 / 96×96 mm — at a common 83 mm case depth
  • Manual output mode with direct percentage setting, useful when commissioning a heater
  • Non-volatile memory retains setpoints and parameters without a backup battery
  • Screw terminals tightened to 0.74–0.90 N·m; no special tooling required at the panel

Works with

The parts that go into the same panel and are usually ordered with it.

Compatible sensors & outputs

also supplied as dual-output temperature controller, relay plus SSR controller

Show supported sensors & probe links (8: K, E, J, N, T, R / S / B, Pt100, Cu50)

Output types and what goes with them

OutputRatingOrder with it
Electromagnetic relay3 A at 250 VAC, resistive—
SSR drive, 12 VDCDrives a solid state relay; the module carries the loadSSR-DA single phase 10–40 A
Current output, 4–20 mAInto a controller or recorder input—
SCR / triac, zero-crossPhase-angle or zero-cross firingBDTY SCR voltage regulator

Front panel

Two displays and four keys. The upper display carries the process value, the lower the set point and the parameter you are editing - which is why the same two digits can mean a temperature on one screen and a menu code on the next. Everything else on the front is a lamp or a key.

BT6 front panel overview

BT6 front panel overview
Display 1 shows the process value; display 2 shows the set value and the parameter settings.

Indicator lamps

AT
Auto-tuning is running.
OUT1
Main control output is on.
OUT2
Second output is on.
AL1
Alarm 1 is active.
AL2
Alarm 2 is active.
A/M
Auto or manual mode.
10–100%
Output percentage

Keys

SET
Main and sub-menu entry; confirm a parameter edit.
▼
Decrease a value; parameter toggle; the other way into auto-tuning.
▲
Increase a value; parameter toggle; manual mode entry.
◄
Shift the digit cursor, for settings with more than one digit to edit.

Panel sizes and cutouts

  • BT6-A48 × 48 mm (1/16 DIN) front, 46 × 46 mm cut-out
  • BT6-B48 × 96 mm (1/8 DIN) front, 45 × 91 mm cut-out
  • BT6-D72 × 72 mm front, 67 × 67 mm cut-out
  • BT6-E96 × 96 mm (1/4 DIN) front, 91 × 91 mm cut-out
BT6-A 48 × 48 mm mm panel
BT6-A — 48 × 48 mm (1/16 DIN), 46 × 46 mm
BT6-B 48 × 96 mm mm panel
BT6-B — 48 × 96 mm (1/8 DIN), 45 × 91 mm
BT6-D 72 × 72 mm mm panel
BT6-D — 72 × 72 mm, 67 × 67 mm
BT6-E 96 × 96 mm mm panel
BT6-E — 96 × 96 mm (1/4 DIN), 91 × 91 mm

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

Wiring

Both dual-output bodies on one sheet: a contactor arrangement, a solid state relay arrangement, a heater, an alarm beacon and both sensor types, for the AK and the BK block. The two blocks number the same functions differently, so read the panel that matches the code on your instrument.

BT6AK1220 / BT6BK1220 · dual-output wiring

BT6AK1220 / BT6BK1220 · dual-output wiring

A three-wire RTD takes its red lead to terminal 10 on the AK body (5 on the BK) and the other two wires to the pair beside it; the thermocouple sits on 11 and 12 on the AK, and on the pair marked for it on the BK. The jumpers differ by version — 2–5 for the main output, 2–8 for the alarm — and the SSR control pair is 3 and 4.

Download the sheet (PDF)

Documents for this family

All documents

Where it is used

  • Injection moulding, extrusion and blow moulding barrel heating zones
  • Packaging, heat sealing and shrink wrapping machinery
  • Industrial ovens, furnaces and drying equipment

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What panel size and cut-out does the BT6 need?

48×48 / 48×96 / 72×72 / 96×96mm. The cut-out is 46×46 / 45×91 / 67×67 / 91×91mm

Which sensors can the BT6 read?

Thermocouple K, J, R, S, B, E, N, T; RTD PT100 and CU50; linear 0–50mV, 0–5V, 1–5V

What output options does the BT6 have?

Relay, logic-level SSR drive, 4–20mA control or 4–20mA retransmission, by order code

What supply voltage does the BT6 need?

100–240VAC, 50Hz

How accurate is the BT6?

±0.5 °C, at 1°C or 0.1°C, selectable resolution

Does the BT6 have alarm outputs?

Up to 2 alarms; modes 0–6 and P1–P4 (11 modes)

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.