CH series · short body

CD901 96 × 96 mm (1/4 DIN) 220VAC digital PID temperature controller

96 × 96 mm (1/4 DIN) bezel, 92 × 92mm cut-out. Long case, 100mm behind the panel. Three output stages are ordered in this bezel, each with its own order code.

Download manual (PDF) · 11 pages

Body: long case, 100mm (CD only) · see CH902

Ordering & Selection Guide

Five positions. The bezel is the model number itself, then the control mode, the input and its range, the output, and the alarm pair.

PositionOrder codeWhat it selects
1CH102 / CH402 / CH502 / CH702 / CH902Case size: 48 × 48, 48 × 96, 96 × 48, 72 × 72 or 96 × 96mm, 78mm behind the panel
2FControl mode: F reverse acting for heating, D direct acting for cooling
3K02Input and its range: K02 is a K thermocouple over 0–400 °C; other letters select J, R, S, B, E, N, T, Pt100, Cu50 or a linear signal
4M / V / 8Output stage: M relay 250VAC 3A, V SSR drive, 8 current 4–20mA
5*ANAlarm pair: the first letter is alarm 1 and the second is alarm 2, each one of N none, A upper deviation, B lower deviation, C either side of the set point, D deviation band, E upper deviation held, F lower deviation held, G either side held, H process high, J process low, K process high held, L process low held

Technical specifications

Accuracy±0.5 %FS ±1 °C
Supply voltage220VAC 50/60Hz, 10VA
Control methodPID with autotuning, or ON/OFF
IndicationDual 4-digit LED, PV above SV
Setting methodFront-panel membrane keys
AlarmsOne relay output, A/B/C selectable
Body depth78mm behind the panel
Operating environment0–50 °C, 30–85 %RH, no condensation

Output types

PositionOutputLoad
MElectromagnetic relayContact rating 3A at 250VAC. Switches a contactor coil or a small heater directly. The terminal pair is printed on the case diagram and differs between models.
VSSR drive SE-SSR-DAVoltage pulse for an external solid state relay; the load current becomes the relay's rating. The terminal pair is printed on the case diagram.
8Current output4–20mA analogue output for an SCR power regulator or a PLC input. The terminal pair is printed on the case diagram.

Terminal numbers here follow the diagram printed on the side of the instrument. If the unit you receive carries a different numbering, the diagram on the case takes precedence over this page.

Inputs and the probe that suits each

Order codeOutputRangeProbe
KThermocouple0–1372 °C (K02: 0–400 °C)SE-TC-WRNK236
JThermocouple0–750 °C—
EThermocouple0–1000 °CSE-TC-RING
NThermocouple0–1300 °C—
TThermocouple−199.9–400.0 °C—
RThermocouple0–1700 °C—
SThermocouple0–1769 °C—
BThermocouple0–1820 °C—
Pt100RTD−199.9–649.0 °CSE-RTD-PT100
Cu50RTD−50.0–150.0 °CSE-RTD-CU50
WReThermocouple (W5Re/W26Re)0–2320 °C—
JPt100RTD (Japanese Pt100 curve)−199.9–649.0 °CSE-RTD-PT100
0–5V / 1–5VLinearscaled—
0–20mA / 4–20mALinearscaled—

Order codes of this bezel

NoOrder codeOutputTerminals
1CD901FK02-M*ANBuilt-in electromechanical relay, 250VAC 3A, dry contacton the case diagram
2CD901FK02-V*ANVoltage pulse output, 0–12VDC, for an external solid state relayon the case diagram
3CD901FK02-8*ANAnalogue current output, 4–20mA (0–10mA on request)on the case diagram