AC Contactors
CJX2-F Three Pole Contactor
The F frames in three poles: 115 A to 330 A in AC-3, with the contact groups and star-delta kits that match each frame size.

- Use
- Circuits up to 660 V working voltage and 800 A rated current, 50 or 60 Hz; frequent starting and remote switching
- Combination
- Pairs with auxiliary contact groups, air delay heads, mechanical interlocks, star-delta starters and thermal overload relays
- Contacts
- Main contacts normally open, three or four per frame according to the model
- Insulation
- Rated insulation voltage 1000 V, rated impulse withstand 8 kV, rated operational voltage 1000 V
Technical specifications
| Series | CJX2-F large capacity contactor, three pole |
|---|---|
| Use | Circuits up to 660 V working voltage and 800 A rated current, 50 or 60 Hz; frequent starting and remote switching |
| Combination | Pairs with auxiliary contact groups, air delay heads, mechanical interlocks, star-delta starters and thermal overload relays |
| Contacts | Main contacts normally open, three or four per frame according to the model |
| Insulation | Rated insulation voltage 1000 V, rated impulse withstand 8 kV, rated operational voltage 1000 V |
| Standard | IEC 60947-4-1, GB 14048.4 and EN 60947-4-1 |
| Frequency | AC-1, AC-2 and AC-3 at 1200 or 600 operations an hour; AC-4 at 300 |
| Fuse | SCPD fuse fitted as listed per frame |
| Ratings | AC-3 rated current at up to 440 V, AC-1 rated current at 40 °C, and conventional thermal current, with AC-3 power tabulated at 220/240, 380/400, 415, 440, 500, 660/690 and 1000 V |
| CJX2-F115 | 115 A in AC-3 · 200 A in AC-1 · Ith 200 A · 30 kW at 220/240 V · 55 kW at 380/400 V · 59 kW at 415 V · 59 kW at 440 V · 75 kW at 500 V · 80 kW at 660/690 V · 65 kW at 1000 V · screw Φ6 · 10 N·m · fuse RT16-2 250 A |
| CJX2-F150 | 150 A in AC-3 · 250 A in AC-1 · Ith 250 A · 40 kW at 220/240 V · 75 kW at 380/400 V · 80 kW at 415 V · 80 kW at 440 V · 90 kW at 500 V · 100 kW at 660/690 V · 65 kW at 1000 V · screw Φ8 · 18 N·m · fuse RT16-2 355 A |
| CJX2-F185 | 185 A in AC-3 · 275 A in AC-1 · Ith 275 A · 55 kW at 220/240 V · 90 kW at 380/400 V · 100 kW at 415 V · 100 kW at 440 V · 110 kW at 500 V · 110 kW at 660/690 V · 100 kW at 1000 V · screw Φ8 · 18 N·m · fuse RT16-3 425 A |
| CJX2-F225 | 225 A in AC-3 · 315 A in AC-1 · Ith 315 A · 63 kW at 220/240 V · 110 kW at 380/400 V · 110 kW at 415 V · 110 kW at 440 V · 129 kW at 500 V · 129 kW at 660/690 V · 100 kW at 1000 V · screw Φ10 · 35 N·m · fuse RT16-3 500 A |
| CJX2-F265 | 265 A in AC-3 · 350 A in AC-1 · Ith 350 A · 75 kW at 220/240 V · 132 kW at 380/400 V · 140 kW at 415 V · 140 kW at 440 V · 160 kW at 500 V · 160 kW at 660/690 V · 147 kW at 1000 V · screw Φ10 · 35 N·m · fuse RT16-3 630 A |
| CJX2-F330 | 330 A in AC-3 · 400 A in AC-1 · Ith 400 A · 100 kW at 220/240 V · 160 kW at 380/400 V · 180 kW at 415 V · 200 kW at 440 V · 200 kW at 500 V · 220 kW at 660/690 V · 160 kW at 1000 V · screw Φ10 · 35 N·m · fuse RT16-4 800 A |
| CJX2-F400 | 400 A in AC-3 · 500 A in AC-1 · Ith 450 A · 110 kW at 220/240 V · 200 kW at 380/400 V · 220 kW at 415 V · 250 kW at 440 V · 257 kW at 500 V · 280 kW at 660/690 V · 185 kW at 1000 V · 35 · fuse RT16-4 800 A |
| CJX2-F500 | 500 A in AC-3 · 700 A in AC-1 · Ith 630 A · 147 kW at 220/240 V · 250 kW at 380/400 V · 280 kW at 415 V · 295 kW at 440 V · 355 kW at 500 V · 335 kW at 660/690 V · 335 kW at 1000 V · Φ10, 35 · fuse RT16-4 1000 A |
| CJX2-F630 | 630 A in AC-3 · 1000 A in AC-1 · Ith 800 A · 220 kW at 220/240 V · 335 kW at 380/400 V · 375 kW at 415 V · 400 kW at 440 V · 400 kW at 500 V · 450 kW at 660/690 V · 450 kW at 1000 V · Φ12, 58 · fuse RT16-4 1250 A |
| CJX2-F780 | 780 A in AC-3 · 1600 A in AC-1 · Ith 1000 A · 220 kW at 220/240 V · 400 kW at 380/400 V · 425 kW at 415 V · 425 kW at 440 V · 450 kW at 500 V · 475 kW at 660/690 V · 475 kW at 1000 V · Φ12, 58 · fuse RT16 1250 A |
| CJX2-F800 | 800 A in AC-3 · 1600 A in AC-1 · Ith 1000 A · 220 kW at 220/240 V · 400 kW at 380/400 V · 425 kW at 415 V · 450 kW at 440 V · 450 kW at 500 V · 475 kW at 660/690 V · 450 kW at 1000 V · Φ12, 58 · fuse RT16 1250 A |
Product overview
Part no. SE-CJX2-F-2
Also known as: Chint CJX2-F · CJX2-F contactor · CJX2-F AC contactor
The large F frame in three poles, for the circuits that carry a whole machine rather than a motor: a hundred and fifteen to three hundred and thirty amps in AC-3, up to a thousand volts, with matching auxiliary groups, delay heads and star-delta kits.
Key features
- 115 A to 330 A in AC-3
- Up to 1000 V rated operational voltage
- Star-delta and interlock kits available
Works with
The parts that go into the same panel and are usually ordered with it.
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All AC Contactors
CJX2 AC Contactor
SE-CJX2
A contactor is the mechanical answer to the same job a solid state relay does: switch a heater or a motor from a control signal. CJX2 covers the…
View details
CJX2-F Reversing Contactor
SE-CJX2-F
The large F frames built as a reversing pair: two contactors side by side with the interlocking bar across them, so a forward command cannot meet a…
View details
CJX2-F Four Pole Contactor
SE-CJX2-F-3
The same large F frame with four main contacts, for the supplies where the neutral breaks with the phases or where a second load rides on the same…
View details
CJX2N AC Contactor
SE-CJX2N
The contactor with the auxiliary set already built in, so a panel that needs one NO and one NC contact does not have to buy the block. Nine to…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.