AC Contactors
CJX2-F Four Pole Contactor
The F frames in four poles, for circuits where the neutral has to break with the phases: 115 A to 780 A in the same case family.

- Use
- Four-pole switching for circuits up to 660 V, where the neutral or a second load has to break with the phases
- Contacts
- Four main contacts normally open
- Insulation
- Rated insulation voltage 1000 V, rated impulse withstand 8 kV, rated operational voltage 1000 V
- Standard
- IEC 60947-4-1, GB 14048.4 and EN 60947-4-1
Technical specifications
| Series | CJX2-F large capacity contactor, four pole |
|---|---|
| Use | Four-pole switching for circuits up to 660 V, where the neutral or a second load has to break with the phases |
| Contacts | Four main contacts normally open |
| Insulation | Rated insulation voltage 1000 V, rated impulse withstand 8 kV, rated operational voltage 1000 V |
| Standard | IEC 60947-4-1, GB 14048.4 and EN 60947-4-1 |
| Frequency | AC-1, AC-2 and AC-3 at 1200 or 600 operations an hour; AC-4 at 300 |
| CJX2-F1154 | 115 A in AC-3 · 30 kW at 220/230 V · 55 kW at 380/400 V · 59 kW at 415 V · 59 kW at 440 V · 75 kW at 500 V · 80 kW at 660/690 V · 65 kW at 1000 V |
| CJX2-F1504 | 150 A in AC-3 · 40 kW at 220/230 V · 75 kW at 380/400 V · 80 kW at 415 V · 80 kW at 440 V · 90 kW at 500 V · 100 kW at 660/690 V · 65 kW at 1000 V |
| CJX2-F1854 | 185 A in AC-3 · 55 kW at 220/230 V · 90 kW at 380/400 V · 100 kW at 415 V · 100 kW at 440 V · 110 kW at 500 V · 110 kW at 660/690 V · 100 kW at 1000 V |
| CJX2-F2254 | 225 A in AC-3 · 63 kW at 220/230 V · 110 kW at 380/400 V · 110 kW at 415 V · 110 kW at 440 V · 129 kW at 500 V · 129 kW at 660/690 V · 100 kW at 1000 V |
| CJX2-F2654 | 265 A in AC-3 · 75 kW at 220/230 V · 132 kW at 380/400 V · 140 kW at 415 V · 140 kW at 440 V · 160 kW at 500 V · 160 kW at 660/690 V · 147 kW at 1000 V |
| CJX2-F3304 | 330 A in AC-3 · 100 kW at 220/230 V · 160 kW at 380/400 V · 180 kW at 415 V · 200 kW at 440 V · 200 kW at 500 V · 220 kW at 660/690 V · 160 kW at 1000 V |
| CJX2-F4004 | 400 A in AC-3 · 110 kW at 220/230 V · 200 kW at 380/400 V · 220 kW at 415 V · 250 kW at 440 V · 257 kW at 500 V · 280 kW at 660/690 V · 185 kW at 1000 V |
| CJX2-F5004 | 500 A in AC-3 · 147 kW at 220/230 V · 250 kW at 380/400 V · 280 kW at 415 V · 295 kW at 440 V · 355 kW at 500 V · 335 kW at 660/690 V · 335 kW at 1000 V |
| CJX2-F6304 | 630 A in AC-3 · 200 kW at 220/230 V · 335 kW at 380/400 V · 375 kW at 415 V · 400 kW at 440 V · 400 kW at 500 V · 450 kW at 660/690 V · 425 kW at 1000 V |
| CJX2-F7804 | 780 A in AC-3 · 220 kW at 220/230 V · 400 kW at 380/400 V · 425 kW at 415 V · 425 kW at 440 V · 450 kW at 500 V · 475 kW at 660/690 V · 450 kW at 1000 V |
Product overview
Part no. SE-CJX2-F-3
Also known as: Chint CJX2-F · CJX2-F contactor · CJX2-F AC contactor
The same large F frame with four main contacts, for the supplies where the neutral breaks with the phases or where a second load rides on the same contactor. A hundred and fifteen to seven hundred and eighty amps in AC-3, up to a thousand volts.
Key features
- Four main contacts normally open
- 115 A to 780 A in AC-3
- Up to 1000 V rated operational voltage
Works with
The parts that go into the same panel and are usually ordered with it.
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related guides
Related models
All AC Contactors
CJX2 AC Contactor
SE-CJX2
A contactor is the mechanical answer to the same job a solid state relay does: switch a heater or a motor from a control signal. CJX2 covers the…
View details
CJX2-F Reversing Contactor
SE-CJX2-F
The large F frames built as a reversing pair: two contactors side by side with the interlocking bar across them, so a forward command cannot meet a…
View details
CJX2-F Three Pole Contactor
SE-CJX2-F-2
The large F frame in three poles, for the circuits that carry a whole machine rather than a motor: a hundred and fifteen to three hundred and thirty…
View details
CJX2N AC Contactor
SE-CJX2N
The contactor with the auxiliary set already built in, so a panel that needs one NO and one NC contact does not have to buy the block. Nine to…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.
