Thermocouples & RTD Sensors

Fibreglass-lead probe, K thermocouple, 3 m lead

The 3 m build of the k thermocouple version.

K E Type Probe Thermocouple Temperature Sensor
K/E Probe: Spring-loaded thermocouple probe…; 1m / 1.5m / 2m / 3m / 4m / 5m, and any other length to order; 4mm U-type fork terminals, red positive and blue negative.
Output
K thermocouple, 3 m lead
Bezel
probe
Panel cut-out
process thread
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

Product typeSpring-loaded thermocouple probe, for a bracket or tapped hole where the probe has to be pushed against the part rather than hang in the air
ElementK or E type thermocouple, or Pt100 RTD wired three-lead, as standard; S, R, B, N, J, T, WRe and WFT to order
Temperature range0–400°C
ToleranceClass 1 or Class 2 to be stated with the order (IEC 60584)
Probe diameterØ5mm
Insertion length (L)50mm, 100mm, 150mm or 200mm
Overall length129mm, 179mm, 229mm or 279mm — the spring housing and hex add 79mm to L
Housing59mm spring housing, 8mm thread section, 11mm hex across flats
Lead length1m / 1.5m / 2m / 3m / 4m / 5m, and any other length to order
Lead insulationBraided shielded high-temperature cable
Custom versionsRod length, thread, lead length and lead material are made to order; other specifications are quoted from the drawing
Termination4mm U-type fork terminals, red positive and blue negative; plug terminals to order
MountingThread section through a bracket or a tapped hole, with the spring holding the tip against the part
Typical useExtruder barrels, injection moulding machines, moulds, platens and ovens where the probe has to stay in contact as the machine heats and expands
WiringTwo-wire for K and E — red positive, blue negative — and three-wire for Pt100. Confirm the colour code on the lead before wiring, and check that the controller input is set to the element fitted.

Product overview

Part no. SE-TC-KEindustry model TC-KE

Also known as: K/E temperature sensor · K/E probe

A Ø5mm probe in a spring housing. The thread section fixes it to a bracket or a tapped hole, and the spring keeps the tip pressed against the part, so the reading follows the metal as the machine heats and expands. K, E and Pt100 as standard, with S, R, B, N, J, T, WRe and WFT built to order.

Ordering code

K · 3 m

The 3 m build of the k thermocouple version.

Order codeK · 3 m
Bezel (mm)probe
Cut-out (mm)process thread
OutputK thermocouple, 3 m lead
Output terminalsfork or pin terminals
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: The lead length is what the panel distance decides; the element is what the instrument reads

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Reading this order code

How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.

PositionReadsMeaning
elementKSensing element inside the probe
lead3 mLead length to the panel; 1 m to 5 m are stock lengths
option—Other lengths, diameters and threads to order
Output terminals: fork or pin terminals·The lead length is what the panel distance decides; the element is what the instrument reads

Key features

  • The spring housing is the reason to fit this instead of a rigid probe: the tip stays in contact as the barrel grows, so the reading does not drift away from the setpoint.
  • 50mm to 200mm of insertion, with the overall length following 79mm behind it.
  • Braided shielded lead in 1m, 1.5m, 2m or 3m.
  • 4mm U-type fork terminals, red positive and blue negative, land straight on a controller's screw terminals.
  • K, E and Pt100 from stock; S, R, B, N, J, T, WRe and WFT to order.

Works with

The parts that go into the same panel and are usually ordered with it.

How to specify

Three choices: element, insertion length and lead. SH-K-100-200 is a K type element, 100 mm of insertion in the spring housing, on a 2 m lead.

SHFamily
KElement
100Insertion, mm
200Lead, cm

Fixed in this familyChosen when ordering

PositionCodeSelects
FamilySHSpring-housing probe
ElementKK type, standard
EE type, standard
PPt100 RTD, 3-wire
JJ type, to order
TT type, to order
NN type, to order
SS type, to order
RR type, to order
BB type, to order
WWRe 3/25, to order
FWFT, to order
Insertion, mm5050 mm probe length
100100 mm probe length
150150 mm probe length
200200 mm probe length
Lead, cm1001 m lead
2002 m lead
3003 m lead
5005 m lead
  • The probe length and the overall length move together: 50, 100, 150 and 200 mm of probe give 129, 179, 229 and 279 mm over the spring housing and hex.
  • S, R, B, N, J, T, WRe and WFT elements are made to order and carry a longer lead time than K and E.

Dimensions

L, the thread and the lead length are the three dimensions that have to be settled before a probe can be designed into a machine. Everything else on these sensors is fixed by the family.

Ø5L = 50 / 100 / 150 / 200 mm129 / 179 / 229 / 279 mm overall59 mm spring housing1 / 2 / 3 / 5 m

Product photos

Probe-type thermocouple with spring housing, M8 thread section and braided lead
The probe on its own: Ø5 shaft, spring housing and the braided lead with U-type forks.
Close-up of the spring housing, hex and the red and blue fork terminals
Spring housing and hex at the top of the shaft; red fork on +, blue on −.

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What does the spring actually do?

It holds the tip against the part as the machine heats. A rigid probe in a fixed bracket loses contact when a barrel grows by a few tenths of a millimetre, and a thermocouple sitting a couple of millimetres off the surface reads the air in the gap, not the metal. The spring takes up that movement, so the reading stays where the setpoint expects it.

Which element should I order?

K for general heating work, E where you want more signal per degree and the process stays under the E type ceiling, Pt100 where the controller takes an RTD input and the accuracy matters at the low end, and S, R, B or WRe for the high-temperature end. J, T, N and WFT are made to order for controllers or processes that already specify them.

How deep does the probe have to go?

The junction is at the closed tip, so the probe has to reach the point you want to measure. Fit the shortest length that reaches it — the thread section holds the housing and the spring takes up the rest, so a longer probe buys nothing but a slower response.

The reading falls when the machine heats up. Why?

On a thermocouple, the two leads are reversed. Swap them at the controller terminals and the reading will follow the process. If the reading is erratic rather than inverted, look at the braid: a shield earthed at both ends makes a loop, and the loop picks up exactly the noise the shield was meant to stop.

Certification and model-specific options

Certification

If CE or RoHS documentation is required, identify the exact model and ask us to confirm which current documents apply with the quotation. ATEX / IECEx zone-rated assemblies are not listed in this range; confirm requirements before specifying.

OEM and private label

Private-label marking or packaging may be available for selected probe models. The marking locations, supported construction and minimum quantity are confirmed against the model and order in the quotation.

What can be changed

Thread, sheath, lead insulation, terminal style and insertion length depend on the probe model and construction. Send the drawing or installation dimensions and we will confirm available options and quote accordingly.

Tolerance has to be stated

A tolerance class is not implied by a part number. Say Class 1 or Class 2 for K and E type (IEC 60584), Class A or B for Pt100 (IEC 60751), on the order — otherwise the probe is built to the standard class and the loop may not hold the accuracy you designed for.

Pressure

None of these probes is rated for pressure service. If the sensor goes into a pressurised pipe or vessel, ask for a thermowell and we will supply a probe that fits it — a bare sheath in a pressurised line is a leak waiting to happen.

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.