Thermocouples & RTD Sensors
Simple-Type Thermocouple or RTD | 4 × 40mm Probe, Clamp Mount, K / E / Pt100 / Cu50
Clamp-on sensor on a 4 × 40 mm stainless probe: K, E, Pt100 or Cu50 element, 0–400 °C, a 1, 2, 3 or 5m lead and 4mm U-type fork terminals.

- Temperature range
- 0–400 °C
- Product type
- Clamp-on sensor for a surface where the probe cannot be inserted and no thread can be added
- Element
- K, E, Pt100 or Cu50
- Probe
- 4 × 40 mm stainless probe, diameter × length
Technical specifications
| Product type | Clamp-on sensor for a surface where the probe cannot be inserted and no thread can be added |
|---|---|
| Element | K, E, Pt100 or Cu50 |
| Temperature range | 0–400 °C |
| Probe | 4 × 40 mm stainless probe, diameter × length |
| Probe diameter | 4mm as standard; 3mm, 5mm and 6mm to order |
| Probe material | 201 stainless steel as standard; 304 to order |
| Tolerance | Class 1 for K and E, Class A for Pt100 and Cu50 as standard |
| Lead length | 1 / 1.5 / 2 / 3 / 4 / 5 m from stock; other lengths to order |
| Lead version | Fibreglass braided lead as standard: K and E on that lead, Pt100 on a silver-plated or a rubber lead, and K also on a waterproof lead |
| Cable | Silver-plated core under a metal braid, or a yarn-wrapped glass-fibre jacket |
| Termination | 4mm U-type fork terminals; on the thermocouple versions the leads follow the polarity marked on the terminal block: under ANSI colour coding the negative lead is red and the positive lead takes the colour of the type (yellow for K, blue for T, white for J), and the Pt100 leads land as the terminal diagram shows |
| Mounting | Clamp ferrule bolted to the part, with the probe pressed against it |
| Wiring | Two-wire for K and E and three-wire for Pt100; wire Cu50 to the controller's RTD input and confirm the terminal arrangement on the instrument. |
| Typical use | Machine tools, plastics machinery, boilers, heating and temperature-control equipment and automation, where the probe has to be clamped to a surface |
Product overview
Part no. SE-TC-4X40industry model TC-4X40
Also known as: Simple-Type Thermocouple temperature sensor · Simple-Type Thermocouple probe
The plainest sensor in the range: a 4 × 40 mm stainless probe on a braided lead, clamped against the part instead of screwed into it. Bolt the clamp to the machine, press the probe against the surface and tighten the ferrule screw — there is no thread to tap and no adapter to fit. K, E, Pt100 or Cu50 element, a 0–400 °C window and 1, 2, 3 or 5m of lead.
Key features
- A 4 × 40 mm probe in 201 stainless steel as standard; 304 to order — short and thin, so it reaches into a tight space and answers in about a second.
- Clamped, not threaded: the ferrule bolts to the part and the probe presses against it, so a surface with no room for a tapped hole still gets a reading.
- K, E, Pt100 or Cu50 element, all on the same body, so one spare covers the machines on a line.
- Silver-plated core under a metal braid, or a yarn-wrapped glass-fibre jacket; both are available, and the braid is the one to take where the lead is dragged.
- 4mm U-type fork terminals, red on + and blue on −, land straight on a controller's screw terminals.
- 1, 2, 3 or 5m of lead as standard, longer or shorter to order.
Works with
The parts that go into the same panel and are usually ordered with it.
Product photos


Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related guides
How to Choose a Threaded Temperature Sensor: K, E Thermocouple or Pt100 RTD
A selection and installation guide for M6 / M8 threaded temperature sensor probes: how thermocouples and RTDs differ, which element to specify, how thread size and mounting affect…
Read guide Technical Guides · 2026-08-23How to Wire REX-C100, REX-C700 and REX-C400/C900 Temperature Controllers
English wiring diagrams for REX-series temperature controllers, including relay, AC contactor, SSR, K-type thermocouple and 3-wire PT100 connections.
Read guide Technical Guides · 2026-08-23How to Wire TCN4S and TCN4H/L/M Temperature Controllers: Contactor and SSR Methods
Terminal-by-terminal wiring instructions for the TCN4S-14RV and TCN4H/L/M-14RV PID temperature controllers, covering AC contactor (relay output) wiring, BSSR-25DA solid-state…
Read guideRelated models
All Thermocouples & RTD Sensors
Surface Mount Patch Thermocouple — K, E and Pt100
SE-TC-RING
A patch thermocouple measures the surface it is screwed to, not the air around it: the junction sits in a stainless steel patch with a 5mm bore, and…
View details
Sheathed Thermocouple or Pt100 RTD | Cast Aluminium Head, G1/2, 6mm Sheath
SE-TC-WRNK236
One mechanical version, two elements. The WRNK-236 takes a K type thermocouple for readings up to 0–800 °C; the WZP-236 takes a Pt100 for the colder…
View details
NTC Thermistor Temperature Sensor Probe | Stainless, Waterproof, Custom Lead
SE-NTC-PROBE
An NTC thermistor reads resistance rather than microvolts, so the same probe that suits a controller also suits a $5 thermostat: the resistance…
View details
K/E Type Probe Thermocouple Temperature Sensor
SE-TC-KE
A Ø5mm probe in a spring housing. The thread section fixes it to a bracket or a tapped hole, and the spring keeps the tip pressed against the part,…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.