Thermocouples & RTD Sensors
Fibreglass-lead probe, Pt100 RTD, 3 m lead
The 3 m build of the pt100 rtd version.

- Output
- Pt100 RTD, 3 m lead
- Bezel
- probe
- Panel cut-out
- process thread
Technical specifications
| Product type | Spring-loaded thermocouple probe, for a bracket or tapped hole where the probe has to be pushed against the part rather than hang in the air |
|---|---|
| Element | K or E type thermocouple, or Pt100 RTD wired three-lead, as standard; S, R, B, N, J, T, WRe and WFT to order |
| Temperature range | 0–400°C |
| Tolerance | Class 1 or Class 2 to be stated with the order (IEC 60584) |
| Probe diameter | Ø5mm |
| Insertion length (L) | 50mm, 100mm, 150mm or 200mm |
| Overall length | 129mm, 179mm, 229mm or 279mm — the spring housing and hex add 79mm to L |
| Housing | 59mm spring housing, 8mm thread section, 11mm hex across flats |
| Lead length | 1m / 1.5m / 2m / 3m / 4m / 5m, and any other length to order |
| Lead insulation | Braided shielded high-temperature cable |
| Custom versions | Rod length, thread, lead length and lead material are made to order; other specifications are quoted from the drawing |
| Termination | 4mm U-type fork terminals, red positive and blue negative; plug terminals to order |
| Mounting | Thread section through a bracket or a tapped hole, with the spring holding the tip against the part |
| Typical use | Extruder barrels, injection moulding machines, moulds, platens and ovens where the probe has to stay in contact as the machine heats and expands |
| Wiring | Two-wire for K and E — red positive, blue negative — and three-wire for Pt100. Confirm the colour code on the lead before wiring, and check that the controller input is set to the element fitted. |
Product overview
Part no. SE-TC-KEindustry model TC-KE
Also known as: K/E temperature sensor · K/E probe
A Ø5mm probe in a spring housing. The thread section fixes it to a bracket or a tapped hole, and the spring keeps the tip pressed against the part, so the reading follows the metal as the machine heats and expands. K, E and Pt100 as standard, with S, R, B, N, J, T, WRe and WFT built to order.
Ordering code
Pt100 · 3 m
The 3 m build of the pt100 rtd version.
| Order code | Pt100 · 3 m |
|---|---|
| Bezel (mm) | probe |
| Cut-out (mm) | process thread |
| Output | Pt100 RTD, 3 m lead |
| Output terminals | fork or pin terminals |
| Input | Universal, K thermocouple fitted |
| Alarm | Two relays, A to L selectable |
| Supply | 220VAC 50/60Hz, 10VA |
What it can switch: The lead length is what the panel distance decides; the element is what the instrument reads
Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.
Other output stages of the same bezel
Reading this order code
How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.
| Position | Reads | Meaning |
|---|---|---|
| element | Pt100 | Sensing element inside the probe |
| lead | 3 m | Lead length to the panel; 1 m to 5 m are stock lengths |
| option | — | Other lengths, diameters and threads to order |
Key features
- The spring housing is the reason to fit this instead of a rigid probe: the tip stays in contact as the barrel grows, so the reading does not drift away from the setpoint.
- 50mm to 200mm of insertion, with the overall length following 79mm behind it.
- Braided shielded lead in 1m, 1.5m, 2m or 3m.
- 4mm U-type fork terminals, red positive and blue negative, land straight on a controller's screw terminals.
- K, E and Pt100 from stock; S, R, B, N, J, T, WRe and WFT to order.
Works with
The parts that go into the same panel and are usually ordered with it.
How to specify
Three choices: element, insertion length and lead. SH-K-100-200 is a K type element, 100 mm of insertion in the spring housing, on a 2 m lead.
Fixed in this familyChosen when ordering
| Position | Code | Selects |
|---|---|---|
| Family | SH | Spring-housing probe |
| Element | K | K type, standard |
| E | E type, standard | |
| P | Pt100 RTD, 3-wire | |
| J | J type, to order | |
| T | T type, to order | |
| N | N type, to order | |
| S | S type, to order | |
| R | R type, to order | |
| B | B type, to order | |
| W | WRe 3/25, to order | |
| F | WFT, to order | |
| Insertion, mm | 50 | 50 mm probe length |
| 100 | 100 mm probe length | |
| 150 | 150 mm probe length | |
| 200 | 200 mm probe length | |
| Lead, cm | 100 | 1 m lead |
| 200 | 2 m lead | |
| 300 | 3 m lead | |
| 500 | 5 m lead |
- The probe length and the overall length move together: 50, 100, 150 and 200 mm of probe give 129, 179, 229 and 279 mm over the spring housing and hex.
- S, R, B, N, J, T, WRe and WFT elements are made to order and carry a longer lead time than K and E.
Dimensions
L, the thread and the lead length are the three dimensions that have to be settled before a probe can be designed into a machine. Everything else on these sensors is fixed by the family.
Product photos


Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Frequently asked questions
What does the spring actually do?
It holds the tip against the part as the machine heats. A rigid probe in a fixed bracket loses contact when a barrel grows by a few tenths of a millimetre, and a thermocouple sitting a couple of millimetres off the surface reads the air in the gap, not the metal. The spring takes up that movement, so the reading stays where the setpoint expects it.
Which element should I order?
K for general heating work, E where you want more signal per degree and the process stays under the E type ceiling, Pt100 where the controller takes an RTD input and the accuracy matters at the low end, and S, R, B or WRe for the high-temperature end. J, T, N and WFT are made to order for controllers or processes that already specify them.
How deep does the probe have to go?
The junction is at the closed tip, so the probe has to reach the point you want to measure. Fit the shortest length that reaches it — the thread section holds the housing and the spring takes up the rest, so a longer probe buys nothing but a slower response.
The reading falls when the machine heats up. Why?
On a thermocouple, the two leads are reversed. Swap them at the controller terminals and the reading will follow the process. If the reading is erratic rather than inverted, look at the braid: a shield earthed at both ends makes a loop, and the loop picks up exactly the noise the shield was meant to stop.
Certification and model-specific options
Certification
If CE or RoHS documentation is required, identify the exact model and ask us to confirm which current documents apply with the quotation. ATEX / IECEx zone-rated assemblies are not listed in this range; confirm requirements before specifying.
OEM and private label
Private-label marking or packaging may be available for selected probe models. The marking locations, supported construction and minimum quantity are confirmed against the model and order in the quotation.
What can be changed
Thread, sheath, lead insulation, terminal style and insertion length depend on the probe model and construction. Send the drawing or installation dimensions and we will confirm available options and quote accordingly.
Tolerance has to be stated
A tolerance class is not implied by a part number. Say Class 1 or Class 2 for K and E type (IEC 60584), Class A or B for Pt100 (IEC 60751), on the order — otherwise the probe is built to the standard class and the loop may not hold the accuracy you designed for.
Pressure
None of these probes is rated for pressure service. If the sensor goes into a pressurised pipe or vessel, ask for a thermowell and we will supply a probe that fits it — a bare sheath in a pressurised line is a leak waiting to happen.
Related guides
How to Choose a Threaded Temperature Sensor: K, E Thermocouple or Pt100 RTD
A selection and installation guide for M6 / M8 threaded temperature sensor probes: how thermocouples and RTDs differ, which element to specify, how thread size and mounting affect…
Read guide Technical Reference · 2026-11-16K-Type Thermocouple Reference Table, 0 to 1300 °C
The millivolt output of a K thermocouple at every 10 °C, the cold-junction correction that turns a meter reading into a temperature, and the tolerance a standard probe is allowed.
Read guide Technical Guides · 2026-11-26TEL96-9001 or TEL96-2001: Choosing the Right Oven Temperature Controller
The TEL96 series is a 96 x 96 mm on/off oven temperature controller built around a K-type thermocouple input and a 10 A relay contact. It is made in two versions, the TEL96-9001…
Read guideRelated models
All Thermocouples & RTD Sensors
Spring Loaded M12 Thermocouple Temperature Sensor
SE-TC-M12
A spring-loaded M12 sensor. The thread fixes it in the hole and the spring takes up the difference as the body heats and grows, so the tip stays…
View details
Simple-Type Thermocouple or RTD | 4 × 40mm Probe, Clamp Mount, K / E / Pt100 / Cu50
SE-TC-4X40
The plainest sensor in the range: a 4 × 40 mm stainless probe on a braided lead, clamped against the part instead of screwed into it. Bolt the clamp…
View details
Sheathed Thermocouple or Pt100 RTD | Cast Aluminium Head, G1/2, 6mm Sheath
SE-TC-WRNK236
One mechanical version, two elements. The WRNK-236 takes a K type thermocouple for readings up to 0–800 °C; the WZP-236 takes a Pt100 for the colder…
View details
NTC Thermistor Temperature Sensor Probe | Stainless, Waterproof, Custom Lead
SE-NTC-PROBE
An NTC thermistor reads resistance rather than microvolts, so the same probe that suits a controller also suits a $5 thermostat: the resistance…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.
