Insulation Monitors
SZID Vehicle-Grade Insulation Monitor, AC and DC
Vehicle-grade AC and DC insulation monitor that publishes resistance as a value for a battery management system, with a galvanic barrier to the CAN bus.

- Output, SZID-xMxxxx-x
- Riso published over CAN from 0 to 1000 VDC; 0 to 750 VAC cannot be measured
- Output, SZID-xDxxxx-x
- Riso+ and Riso− published from 20 to 1000 VDC, or 0 to 20 VDC with Riso+ forced equal to Riso−
- DC system
- 0–1000 VDC, tested at 1050 VDC; accuracy 1 %
- Supply
- 9–36 VDC, input power ≤2 W
Technical specifications
| Product | DC insulation monitor for unearthed systems |
|---|---|
| Output, SZID-xMxxxx-x | Riso published over CAN from 0 to 1000 VDC; 0 to 750 VAC cannot be measured |
| Output, SZID-xDxxxx-x | Riso+ and Riso− published from 20 to 1000 VDC, or 0 to 20 VDC with Riso+ forced equal to Riso− |
| DC system | 0–1000 VDC, tested at 1050 VDC; accuracy 1 % |
| Supply | 9–36 VDC, input power ≤2 W |
| Insulation resistance range | 0–50 MΩ; above 50 MΩ the value reads as 50 MΩ |
| Accuracy at 0–100 kΩ | ±12 kΩ with Cy ≤2 µF |
| Accuracy at 100 kΩ–1 MΩ and 1 MΩ–50 MΩ | ±10 % with Cy ≤2 µF |
| Response time | 4 s to 5 s depending on Riso and Cy; 8 s and 12 s at 1 MΩ with 1 µF and 2 µF |
| HV input resistance | 5.1 MΩ per pole while powered; above 500 MΩ when isolated |
| Isolation, HV side to CAN | 3500 VDC, 2500 VAC rms |
| Environment | −40 to +85 °C working and storage, IP55, about 0.5 kg |
Product overview
Part no. SE-GYID-INSULATIONindustry model GYID-INSULATION
Also known as: SZID vehicle-grade insulation monitor
A different animal from the rest: it does not close a relay, it publishes the resistance as a value for a battery management system to read. Sealed aluminium case, wide operating temperature, and a galvanic barrier between the high-voltage side and the CAN bus — this is the one that goes inside a vehicle or a charging cabinet rather than on a panel door.
Key features
- The face, the setting and the response of this version, listed in its own table
- One version per page, because these differ between them
- Photograph and drawing where the factory has supplied one
Works with
The parts that go into the same panel and are usually ordered with it.
Dimensions

Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All Insulation Monitors
SZIM-DAR Certified DC Insulation Monitor
SE-GYIM-DAR
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View details
DAR-60 Certified Monitor for Control Circuits
SE-GYIM-DAR-2
The certified control-circuit version. Along with its larger sibling it is the only unit in the range whose response time is published against the…
View details
UB1K DC Insulation Monitor
SE-UB1K
The kilovolt version: 100 to 1000 VDC floating systems, read pole to earth at 1 kΩ to 10 MΩ, with the alarm relay and the buzzer on the same board.…
View details
UBCH1 Boxed DC Insulation Monitoring Device
SE-UBCH1
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.