Insulation Monitors
UB1K DC Insulation Monitor
DC insulation monitor for 100 to 1000 VDC floating systems, pole to earth at 1 k to 10 M, alarm relay and buzzer, four 5 mm holes at 90 mm centres.

- System voltage measured
- 0–1000 VDC
- Measurement accuracy
- ±2 V from 0 to 400 VDC, ±0.5 % from 400 to 1000 VDC
- Auxiliary supply
- 10–30 VDC
- Auxiliary consumption
- 3 W
Technical specifications
| Product | DC insulation monitor for unearthed systems |
|---|---|
| System voltage measured | 0–1000 VDC |
| Measurement accuracy | ±2 V from 0 to 400 VDC, ±0.5 % from 400 to 1000 VDC |
| Auxiliary supply | 10–30 VDC |
| Auxiliary consumption | 3 W |
| Insulation resistance range | 1 kΩ–10 MΩ across a 100–1000 VDC system |
| Insulation accuracy, Cy² 0–0.8 µF | ≤60 kΩ: ≤3 kΩ · 60 kΩ–1 MΩ: ≤5 % |
| Insulation accuracy, Cy² 0.8–3 µF | ≤60 kΩ: ≤6 kΩ · 60 kΩ–1 MΩ: ≤20 % |
| Alarm relay switching voltage | 400 VAC / 600 VDC |
| Alarm relay switching current | 4 A |
| Alarm relay contact resistance | <100 mΩ |
| Alarm relay insulation | 1000 MΩ |
| Storage / working temperature | −55 to 90 °C / −40 to 75 °C |
| Altitude / humidity | ≤3500 m / ≤90 % |
Product overview
Part no. SE-UB1K
Also known as: UB1K insulation monitor
The kilovolt version: 100 to 1000 VDC floating systems, read pole to earth at 1 kΩ to 10 MΩ, with the alarm relay and the buzzer on the same board. Four Ø5 holes at 90 mm centres fix it, and the drawing below is the cut-out.
Key features
- The face, the setting and the response of this version, listed in its own table
- One version per page, because these differ between them
- Photograph and drawing where the factory has supplied one
Works with
The parts that go into the same panel and are usually ordered with it.
Dimensions

Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All Insulation Monitors
UB100 DC Insulation Monitor
SE-UB100
Same case, same relay, same RS485, built for a low-voltage system instead of a kilovolt bus. Three things change on the card and all three matter…
View details
UBCH1 Boxed DC Insulation Monitoring Device
SE-UBCH1
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View details
UBCH2 Dual-Channel DC Insulation Monitoring Device
SE-UBCH2
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View details
SZIM-DAR Certified DC Insulation Monitor
SE-GYIM-DAR
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.