Solid State Relays & SCR Power Modules
SE-TM4-4-050-Z power regulator, 50 A per phase
SE-TM4-4-050-Z is the 50 A build: a 225 × 110 × 175 mm case on M6 studs, zero-cross fixed-cycle firing, and the same isolated RS485 port as every other rating. Order this one when the element bank is already sized and only the firing mode is in question.

- Output
- SCR output, zero-cross fixed-cycle
- Bezel
- 225 × 110 × 175
- Panel cut-out
- Z1 150 × Z2 133, M6 studs
Technical specifications
| Product Series | SE-TM4 series three-phase power regulator |
|---|---|
| Product Type | Three-phase SCR power regulator |
| Main Supply | 330–440VAC three-phase |
| Working Voltage | 380VAC |
| Control Supply | 110–220VAC single-phase |
| Rated Current | 25A–200A |
| Control Modes | Zero-cross fixed-cycle, open-loop phase shift, constant current, constant voltage, constant power |
| Communication | Isolated RS485, Modbus-RTU |
| Display | Double-row four-digit LED, measured value and setpoint |
| Measurement Accuracy | 0.2%FS |
| Protection | Over-current, over-temperature trip at 85°C, load break, phase loss |
| Cooling | Fan-cooled heatsink with over-temperature trip |
| Mounting | Vertical panel mount, M6 studs |
| Ambient Temperature | -20–40°C |
| Application Load | Three-phase resistive load, silicon carbide and molybdenum elements |
Product overview
Part no. SE-TM4industry model TM4
Also known as: SE-TM Three-Phase SCR Power Regulator · Thyristor Power Controller
SE-TM4 is the three-phase member of the TM power-regulator family: a thyristor pair per phase driven by an isolated trigger board, with the heatsink and fan sized to the current the code names. It regulates a resistive heating load steplessly instead of switching it on and off, so a silicon carbide element, a molybdenum bank or a transformer primary sees a smooth current rather than a duty cycle. Firing mode is selectable between zero-cross fixed-cycle, open-loop phase shift and closed-loop constant current, voltage or power, and the setting can come from the front keys, an analog signal or the isolated RS485 port. Protection covers over-current through a fast electronic trip, over-temperature at the heatsink, load break and phase loss, so a failed element trips the regulator instead of cooking the next one.
Ordering code
SE-TM4-4-050-Z
SE-TM4-4-050-Z is the 50 A build: a 225 × 110 × 175 mm case on M6 studs, zero-cross fixed-cycle firing, and the same isolated RS485 port as every other rating. Order this one when the element bank is already sized and only the firing mode is in question.
| Order code | SE-TM4-4-050-Z |
|---|---|
| Bezel (mm) | 225 × 110 × 175 |
| Cut-out (mm) | Z1 150 × Z2 133, M6 studs |
| Output | SCR output, zero-cross fixed-cycle |
| Output terminals | R/S/T on the top edge, U/V/W on the bottom edge, control on the plug-in strip |
| Input | Universal, K thermocouple fitted |
| Alarm | Two relays, A to L selectable |
| Supply | 220VAC 50/60Hz, 10VA |
What it can switch: Three-phase 380 V resistive load, 50 A per phase, in a 225 × 110 × 175 mm case
Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.
Other output stages of the same bezel
Reading this order code
How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.
| Position | Reads | Meaning |
|---|---|---|
| SE | house prefix | Strong Electric prefix on the factory code |
| TM4 | three-phase family | TM4: three-phase power regulator, thyristor pair per phase |
| 4 | 330-440 VAC | Main supply 330 to 440 VAC |
| 050 | 50 A | 50 A per phase, 225 × 110 × 175 mm case, 2.8 kg |
| Z | Zero-cross fixed-cycle | Zero-cross fixed-cycle firing |
Key features
- Stepless output from zero to full power: zero-cross fixed-cycle, open-loop phase shift, or closed-loop constant current, constant voltage or constant power
- Isolated RS485 Modbus-RTU as standard, so the PLC or the temperature controller upstream sets the output instead of an operator with a potentiometer
- Double-row display shows the measured value and the setpoint together, which is how an operator sees what the regulator is actually delivering while changing the target
- Fast electronic over-current trip, over-temperature trip at 85°C on the heatsink, load-break and phase-loss detection
- One order code names the whole build: current rating, main supply and firing mode, so a repeat order lands on the same regulator
- Fan-cooled heatsink sized per rating, with the airflow path clear at both ends of the case
- R/S/T terminals on the top edge and U/V/W on the bottom edge, so the power cables do not cross the control wiring
- Suited to silicon carbide, molybdenum, tungsten and transformer-coupled loads, where a contactor would arc away its contacts in weeks
- Available from 25A to 200A per phase, in the 380VAC class with a 330–440VAC main supply
- Vertical panel mounting on M6 studs, no separate DIN rail or adapter needed
Works with
The parts that go into the same panel and are usually ordered with it.
PID controller (4–20 mA)
SE-TC4
Order the linear 4–20 mA current-output version to drive this analog power regulator; a pulsed SSR drive output will not regulate it
Matched heat sink
SE-HS-SSR
Size the radiator (and cooling fan for high-current three-phase loads) to the module's operating current
Thermocouple or Pt100
SE-TC-WRNK236
K-type or Pt100 sheathed probe matched to the PID controller input
Reading the order code
Five positions: the house prefix, the family, the main supply, the current per phase and the firing mode. Only the last two change between two builds on the same shelf.
| Position | Reads | Options |
|---|---|---|
| SE | House prefix | Fixed. |
| TM4 | Three-phase family | Three-phase power regulator, one thyristor pair per phase. |
| 2 / 4 | Main supply | 2 / 4 — 110-220 VAC / 330-440 VAC |
| 025 … 200 | Current per phase | 25 / 35 / 45 / 50 / 55 / 60 / 75 / 80 / 90 / 100 / 125 / 150 / 175 / 200 A |
| Z / P / C / V / CV | Firing mode | Z — Zero-cross fixed-cycle; P — Open-loop phase shift; C — Constant current; V — Constant voltage; CV — Constant power |
Case size by current rating
The case grows in three steps as the current rises, and the fixing centres grow with it. Check the depth before ordering: the 200 A build needs 230 mm behind the panel.
| Order code | Current per phase | L × W × H | Fixing centres Z1 × Z2 | Weight |
|---|---|---|---|---|
| SE-TM4-4-025-Z | 25 A | 160 × 115 × 175 mm | 91 × 105 mm | 2.3 kg |
| SE-TM4-4-035-Z | 35 A | 185 × 115 × 175 mm | 91 × 105 mm | 2.5 kg |
| SE-TM4-4-045-Z | 45 A | 225 × 110 × 175 mm | 150 × 133 mm | 2.8 kg |
| SE-TM4-4-050-Z | 50 A | 225 × 110 × 175 mm | 150 × 133 mm | 2.8 kg |
| SE-TM4-4-055-Z | 55 A | 250 × 150 × 200 mm | 150 × 133 mm | 3.9 kg |
| SE-TM4-4-060-Z | 60 A | 250 × 150 × 200 mm | 150 × 133 mm | 3.9 kg |
| SE-TM4-4-075-Z | 75 A | 250 × 150 × 200 mm | 150 × 133 mm | 3.9 kg |
| SE-TM4-4-080-Z | 80 A | 250 × 150 × 200 mm | 150 × 133 mm | 3.9 kg |
| SE-TM4-4-090-Z | 90 A | 250 × 150 × 200 mm | 150 × 133 mm | 3.9 kg |
| SE-TM4-4-100-Z | 100 A | 250 × 150 × 200 mm | 150 × 133 mm | 3.9 kg |
| SE-TM4-4-125-Z | 125 A | 290 × 150 × 200 mm | 171 × 133 mm | 5.1 kg |
| SE-TM4-4-150-Z | 150 A | 340 × 150 × 200 mm | 171 × 133 mm | 5.7 kg |
| SE-TM4-4-175-Z | 175 A | 340 × 150 × 200 mm | 171 × 133 mm | 5.7 kg |
| SE-TM4-4-200-Z | 200 A | 370 × 180 × 230 mm | 175 × 165 mm | 8.3 kg |
Sizing the current
The rating is chosen from the load, not from the heater's nameplate wattage alone: a cold element draws more than a hot one, and the sheet's rule keeps a margin for that.
Current per phase (A) = 1.2 × load (kW) × 1000 ÷ line voltage (V)
The 1.2 factor is the cold-element margin. Round up to the next rating in the table: a load that works out at 96 A takes the 100 A build, not the 90 A one. Above 200 A per phase the answer is a larger frame, not two regulators in parallel.
Derate above 40 °C ambient: the fan moves the same air, but the thyristor junction has less headroom, so a panel that runs hot needs the next rating up.
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related guides
Three-Phase Resistive Heater Power Control: SSR and SCR Selection and Sizing Guide
Line current, not phase current, decides the device rating — and star or delta changes which one you are measuring. This guide works through the current math, the choice between…
Read guide Technical Guides · 2025-08-28BSTY Three-Phase SCR AC Power Regulator: Signal Options, Sizing and Commissioning
Electrical data, control signal selection, current sizing for three-phase resistive loads, soft-start and thermal protection settings, wiring practice and commissioning steps for…
Read guide Technical Guides · 2025-04-12SCR Voltage Regulator Circuit Diagram and Wiring Guide
How to read and apply SCR voltage regulator circuit diagrams for single-phase and three-phase four-wire resistive heating, using the current SCR-100 controller and M1DK…
Read guideRelated models
All Solid State Relays & SCR Power Modules
BDTY Single Phase SCR Voltage Regulator
SE-BDTY
BDTY Series Single-Phase SCR Voltage Regulator is designed for precise AC power regulation of resistive heating loads. It supports multiple analog…
View details
BSTY Three-Phase SCR Voltage Regulator — 150–450A, 3-Phase 380 VAC
SE-BSTY
BSTY provides phase-angle voltage control for 380VAC three-phase resistive heating loads. Choose the current and control-input version to match the…
View details
SCR3L Three-Phase Intelligent SCR Voltage Regulator 60A–200A
SE-SCR3L
SCR3L Series Three-Phase Intelligent SCR Voltage Regulator is an integrated SCR power control module designed for 380VAC three-phase resistive load…
View details
SSR-LA Analog Control SSR — 4–20mA Input, 10A–120A
SE-LA
SSR-LA Series Analog Controlled Solid State Relay is a single-phase solid state voltage regulator module designed for proportional AC load control.…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.