Solid State Relays & SCR Power Modules

SE-TM4-4-150-Z power regulator, 150 A per phase

SE-TM4-4-150-Z is the 150 A build: a 340 × 150 × 200 mm case on M6 studs, zero-cross fixed-cycle firing, and the same isolated RS485 port as every other rating. Order this one when the element bank is already sized and only the firing mode is in question.

SE-TM4 three-phase SCR power regulator with R, S and T terminals on the top edge, a red four-digit double display with OK, up, EsC, down, RUN and STOP keys on the front, U, V and W terminals at the bottom and the fan behind the heatsink
The regulator front on: R/S/T is the incoming three-phase supply at the top edge, U/V/W the load at the bottom, and the two display rows carry the measured value above the setpoint. RUN and STOP start and stop firing without removing power.
Output
SCR output, zero-cross fixed-cycle
Bezel
340 × 150 × 200
Panel cut-out
Z1 171 × Z2 133, M6 studs
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

Product SeriesSE-TM4 series three-phase power regulator
Product TypeThree-phase SCR power regulator
Main Supply330–440VAC three-phase
Working Voltage380VAC
Control Supply110–220VAC single-phase
Rated Current25A–200A
Control ModesZero-cross fixed-cycle, open-loop phase shift, constant current, constant voltage, constant power
CommunicationIsolated RS485, Modbus-RTU
DisplayDouble-row four-digit LED, measured value and setpoint
Measurement Accuracy0.2%FS
ProtectionOver-current, over-temperature trip at 85°C, load break, phase loss
CoolingFan-cooled heatsink with over-temperature trip
MountingVertical panel mount, M6 studs
Ambient Temperature-20–40°C
Application LoadThree-phase resistive load, silicon carbide and molybdenum elements

Product overview

Part no. SE-TM4industry model TM4

Also known as: SE-TM Three-Phase SCR Power Regulator · Thyristor Power Controller

SE-TM4 is the three-phase member of the TM power-regulator family: a thyristor pair per phase driven by an isolated trigger board, with the heatsink and fan sized to the current the code names. It regulates a resistive heating load steplessly instead of switching it on and off, so a silicon carbide element, a molybdenum bank or a transformer primary sees a smooth current rather than a duty cycle. Firing mode is selectable between zero-cross fixed-cycle, open-loop phase shift and closed-loop constant current, voltage or power, and the setting can come from the front keys, an analog signal or the isolated RS485 port. Protection covers over-current through a fast electronic trip, over-temperature at the heatsink, load break and phase loss, so a failed element trips the regulator instead of cooking the next one.

Ordering code

SE-TM4-4-150-Z

SE-TM4-4-150-Z is the 150 A build: a 340 × 150 × 200 mm case on M6 studs, zero-cross fixed-cycle firing, and the same isolated RS485 port as every other rating. Order this one when the element bank is already sized and only the firing mode is in question.

Order codeSE-TM4-4-150-Z
Bezel (mm)340 × 150 × 200
Cut-out (mm)Z1 171 × Z2 133, M6 studs
OutputSCR output, zero-cross fixed-cycle
Output terminalsR/S/T on the top edge, U/V/W on the bottom edge, control on the plug-in strip
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: Three-phase 380 V resistive load, 150 A per phase, in a 340 × 150 × 200 mm case

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Reading this order code

How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.

PositionReadsMeaning
SEhouse prefixStrong Electric prefix on the factory code
TM4three-phase familyTM4: three-phase power regulator, thyristor pair per phase
4330-440 VACMain supply 330 to 440 VAC
150150 A150 A per phase, 340 × 150 × 200 mm case, 5.7 kg
ZZero-cross fixed-cycleZero-cross fixed-cycle firing
Output terminals: R/S/T on the top edge, U/V/W on the bottom edge, control on the plug-in strip·Three-phase 380 V resistive load, 150 A per phase, in a 340 × 150 × 200 mm case

Key features

  • Stepless output from zero to full power: zero-cross fixed-cycle, open-loop phase shift, or closed-loop constant current, constant voltage or constant power
  • Isolated RS485 Modbus-RTU as standard, so the PLC or the temperature controller upstream sets the output instead of an operator with a potentiometer
  • Double-row display shows the measured value and the setpoint together, which is how an operator sees what the regulator is actually delivering while changing the target
  • Fast electronic over-current trip, over-temperature trip at 85°C on the heatsink, load-break and phase-loss detection
  • One order code names the whole build: current rating, main supply and firing mode, so a repeat order lands on the same regulator
  • Fan-cooled heatsink sized per rating, with the airflow path clear at both ends of the case
  • R/S/T terminals on the top edge and U/V/W on the bottom edge, so the power cables do not cross the control wiring
  • Suited to silicon carbide, molybdenum, tungsten and transformer-coupled loads, where a contactor would arc away its contacts in weeks
  • Available from 25A to 200A per phase, in the 380VAC class with a 330–440VAC main supply
  • Vertical panel mounting on M6 studs, no separate DIN rail or adapter needed

Works with

The parts that go into the same panel and are usually ordered with it.

Reading the order code

Five positions: the house prefix, the family, the main supply, the current per phase and the firing mode. Only the last two change between two builds on the same shelf.

PositionReadsOptions
SEHouse prefixFixed.
TM4Three-phase familyThree-phase power regulator, one thyristor pair per phase.
2 / 4Main supply2 / 4 — 110-220 VAC / 330-440 VAC
025 … 200Current per phase25 / 35 / 45 / 50 / 55 / 60 / 75 / 80 / 90 / 100 / 125 / 150 / 175 / 200 A
Z / P / C / V / CVFiring modeZ — Zero-cross fixed-cycle; P — Open-loop phase shift; C — Constant current; V — Constant voltage; CV — Constant power

Case size by current rating

The case grows in three steps as the current rises, and the fixing centres grow with it. Check the depth before ordering: the 200 A build needs 230 mm behind the panel.

Order codeCurrent per phaseL × W × HFixing centres Z1 × Z2Weight
SE-TM4-4-025-Z25 A160 × 115 × 175 mm91 × 105 mm2.3 kg
SE-TM4-4-035-Z35 A185 × 115 × 175 mm91 × 105 mm2.5 kg
SE-TM4-4-045-Z45 A225 × 110 × 175 mm150 × 133 mm2.8 kg
SE-TM4-4-050-Z50 A225 × 110 × 175 mm150 × 133 mm2.8 kg
SE-TM4-4-055-Z55 A250 × 150 × 200 mm150 × 133 mm3.9 kg
SE-TM4-4-060-Z60 A250 × 150 × 200 mm150 × 133 mm3.9 kg
SE-TM4-4-075-Z75 A250 × 150 × 200 mm150 × 133 mm3.9 kg
SE-TM4-4-080-Z80 A250 × 150 × 200 mm150 × 133 mm3.9 kg
SE-TM4-4-090-Z90 A250 × 150 × 200 mm150 × 133 mm3.9 kg
SE-TM4-4-100-Z100 A250 × 150 × 200 mm150 × 133 mm3.9 kg
SE-TM4-4-125-Z125 A290 × 150 × 200 mm171 × 133 mm5.1 kg
SE-TM4-4-150-Z150 A340 × 150 × 200 mm171 × 133 mm5.7 kg
SE-TM4-4-175-Z175 A340 × 150 × 200 mm171 × 133 mm5.7 kg
SE-TM4-4-200-Z200 A370 × 180 × 230 mm175 × 165 mm8.3 kg

Sizing the current

The rating is chosen from the load, not from the heater's nameplate wattage alone: a cold element draws more than a hot one, and the sheet's rule keeps a margin for that.

Current per phase (A) = 1.2 × load (kW) × 1000 ÷ line voltage (V)

The 1.2 factor is the cold-element margin. Round up to the next rating in the table: a load that works out at 96 A takes the 100 A build, not the 90 A one. Above 200 A per phase the answer is a larger frame, not two regulators in parallel.

Derate above 40 °C ambient: the fan moves the same air, but the thyristor junction has less headroom, so a panel that runs hot needs the next rating up.

Supply & OEM

Available with your logoMOQ 10 units·Lead time on quotation·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.