Solid State Relays & SCR Power Modules
SSR-DA Series Single Phase Solid State Relay (SSR)
SSR-DA series solid state relays: 3–32VDC control, 24–380VAC output, 10A–100A, zero-cross switching for heaters and lighting.

- Load Current
- 10A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 100A
- Load Voltage
- 24–380VAC
- Control Voltage
- 3–32VDC
- Control Current
- DC 3–25mA
Technical specifications
| Load Current | 10A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 100A |
|---|---|
| Load Voltage | 24–380VAC |
| Control Voltage | 3–32VDC |
| Control Current | DC 3–25mA |
| On-state Voltage Drop | ≤1.5V |
| Off-state Leakage Current | ≤2mA |
| On-off Time | ≤10ms |
| Dielectric Strength | 2500VAC |
| Insulation Resistance | 1000MΩ / 500VDC |
| Ambient Temperature | −30°C to +75°C |
| Mounting Method | Screw mounting |
| Work Indicator | LED |
| Weight | 132g |
Product overview
Part no. SE-SSR-DA
Also known as: SSR-DA solid state relay · SSR-DA SSR module · SSR-DA standard 45×60 mm footprint
SSR-DA Series single-phase solid state relays from Beijing Strong Electric offer fast, silent zero-cross switching for AC resistive loads. Control input is 3–32VDC, load output 24–380VAC, with rated current from 10A to 100A. Typical uses are heating equipment, ovens, lighting circuits, packaging machines and temperature control systems.
Key features
- Silent switching – no contact bounce, ideal for sensitive environments
- Fast response and long electrical life
- Compact design for easy panel integration
- Fully opto-isolated input/output for safe signal control
- Rated current options from 10A to 100A
- Zero-cross switching for stable control of resistive loads
- Suitable for industrial automation, temperature controllers and AC load switching
Works with
The parts that go into the same panel and are usually ordered with it.
Ordering & Selection Guide
SSR + current + input + output voltage + optional H (480V) + optional R (random). Example: SSR-40DA-H-R.
Output current
Input method
- D
- 4–32VDC
- A
- 80–250VAC
- L
- 4–20mA
- V
- Variable resistor
Output voltage
- A
- AC output
- D
- DC output
Voltage range
- H(480V)
- High-voltage type: 90–480VAC load
- —
- Standard type (24–380VAC): no code
Control method
- R
- Random control (phase-angle switching)
- —
- Zero-cross control: no code
Worked example
SSR-40DA-H-R
Single-phase solid state module
- Standard-voltage zero-cross units omit H and R (e.g. SSR-40DA).
- Current code is rated load current — derate for continuous resistive loads and pair with a heatsink.
Heat sink sizing by relay current
An SSR drops about 1.6 V whatever the load, so the heat it makes is the current times that drop: 40 A is roughly 64 W inside a box the size of a matchbox. The relay's rating only holds with a sink under it, and the sink has to be at or below the thermal resistance in this table.
| Relay current | Heat in the relay | Heat sink at or below | Mounting |
|---|---|---|---|
| 10 A | 16 W | ≤ 5.0 °C/W | Plate 80 × 50 mm |
| 15 A | 24 W | ≤ 3.0 °C/W | Plate 100 × 60 mm |
| 25 A | 40 W | ≤ 2.0 °C/W | Finned 100 × 80 mm |
| 40 A | 64 W | ≤ 1.2 °C/W | Finned 120 × 100 mm |
| 60 A | 96 W | ≤ 0.8 °C/W | Finned 150 × 120 mm, fan assisted |
| 80 A | 128 W | ≤ 0.6 °C/W | Finned 200 × 120 mm, fan assisted |
| 100 A | 160 W | ≤ 0.45 °C/W | Finned 250 × 120 mm, forced air |
Figures assume an ambient of 40 °C, a junction limit of 125 °C and thermal paste between relay and sink. Above 40 °C ambient, derate the current by about 1 % per °C, or fit the next size of sink. A relay mounted without a sink carries a fraction of its rating.
Selecting a solid state relay
Three decisions, in this order: the control mode, the current, the heat sink. Getting them out of order is how a 40A relay ends up switching a 25A load without a heat sink and dies in a month.
1. Choose the control mode
The suffix after the current rating says what does the switching and what it switches.
| Suffix | Control / load |
|---|---|
| AA | AC control, AC load |
| DA | DC control, AC load |
| DD | DC control, DC load |
| VA | Potentiometer control, AC load |
| LA | 4–20mA proportional input, AC load |
| VD | 0–10VDC proportional input, AC load |
2. Size the current
The rated current on the label is not the current you may switch. The coefficient depends on the load: 0.5 for a resistive load, 0.15 for an inductive one.
load current ÷ coefficient = relay current
relay current × coefficient = load current
0.5 — resistive load
0.15 — inductive load
Worked example
A 5A resistive oven needs 5 ÷ 0.5 = 10A, which is an SSR-10DA. The same current on an inductive load needs 5 ÷ 0.15 = 33A, so the 40A version.
3. Choose the heat sink
| I-50 | 1-ph ≤ 15A | compact single-phase block |
|---|---|---|
| W-70 / TH-76 / D-74 | 1-ph ≤ 40A | wide base or TS35 DIN rail |
| W-100 / T-80 / Ic | 1-ph ≤ 60A | wide or tall fins (optional DIN base on T-80) |
| T-110 / Ib / E-105 | 1-ph ≤ 80A | heavy single-phase (E-130 up to 120A) |
| E-52 / H-110 / H-150 | 3-ph ≤ 40–80A | three-phase / industrial; H-series fits 80×80×30mm fan |
| F-120 / Y-80–Y-150 | 3-ph 100–200A | industrial up to 250A; F-120 fits 90×90×30mm fan |
Aluminium extrusion heat sinks for SSR modulesBefore you mount it
An SSR gets hot. Above 10A it must go on a heat sink, with thermal grease between the baseplate and the sink; above 60A add forced air.
Labels and terminals
The front carries six things worth reading before the relay goes into a panel: the brand, the model, the load voltage, the control voltage, the work indicator and the four terminal screws. Load sits on positions 1 and 2, control on 3 and 4 — the pairs are at opposite ends of the body so the mains side and the signal side cannot be confused.
Dimensions & Wiring Diagram

Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related guides
How to Wire REX-C100/C400/C700 Temperature Controllers with Relay and SSR Output
This blog provides a comprehensive guide on wiring REX series temperature controllers, including the C100, C400, and C700 models. It explains both relay and solid-state relay…
Read guide Technical Guides · 2026-11-21Solid State Relay Failure Guide: Short Circuit, Open Circuit, Leakage and False Triggering
Most SSR failures are shorts, not opens — the heater stays on with the control output off. This guide covers the five failure modes seen in the field, the meter tests that…
Read guide Technical Guides · 2026-08-23How to Wire TCN4S and TCN4H/L/M Temperature Controllers: Contactor and SSR Methods
Terminal-by-terminal wiring instructions for the TCN4S-14RV and TCN4H/L/M-14RV PID temperature controllers, covering AC contactor (relay output) wiring, BSSR-25DA solid-state…
Read guideRelated models
All Solid State Relays & SCR Power Modules
SSR-DA Single-Phase SSR — Standard, 10A–100A
SE-DA
SSR-DA Series Single Phase Solid State Relay switches AC loads from a 3–32VDC control signal. It is built for heating equipment, lighting systems,…
View details
SSR-LA Analog Control SSR — 4–20mA Input, 10A–120A
SE-LA
SSR-LA Series Analog Controlled Solid State Relay is a single-phase solid state voltage regulator module designed for proportional AC load control.…
View details
SSR3 Three Phase Solid State Relay — 10A–200A
SE-SSR3
SSR3 Three Phase Solid State Relay is an industrial-grade three-phase, DC-controlled AC solid state switching module. It accepts a 3–32VDC control…
View details
SSR Heat Sink — Aluminium Radiator for SSR Modules
SE-HS-SSR
SSR Heatsink is an aluminium extrusion heat sink for solid state relay modules used in heating, temperature control, motor control, and industrial…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.