Solid State Relays & SCR Power Modules

SSR-DA Series Single Phase Solid State Relay (SSR)

SSR-DA series solid state relays: 3–32VDC control, 24–380VAC output, 10A–100A, zero-cross switching for heaters and lighting.

SSR-40DA Single Phase Solid State Relay
SSR-DA: 10A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 100A; 24–380VAC; 3–32VDC.
Load Current
10A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 100A
Load Voltage
24–380VAC
Control Voltage
3–32VDC
Control Current
DC 3–25mA
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

Load Current10A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 100A
Load Voltage24–380VAC
Control Voltage3–32VDC
Control CurrentDC 3–25mA
On-state Voltage Drop≤1.5V
Off-state Leakage Current≤2mA
On-off Time≤10ms
Dielectric Strength2500VAC
Insulation Resistance1000MΩ / 500VDC
Ambient Temperature−30°C to +75°C
Mounting MethodScrew mounting
Work IndicatorLED
Weight132g

Product overview

Part no. SE-SSR-DA

Also known as: SSR-DA solid state relay · SSR-DA SSR module · SSR-DA standard 45×60 mm footprint

SSR-DA Series single-phase solid state relays from Beijing Strong Electric offer fast, silent zero-cross switching for AC resistive loads. Control input is 3–32VDC, load output 24–380VAC, with rated current from 10A to 100A. Typical uses are heating equipment, ovens, lighting circuits, packaging machines and temperature control systems.

Key features

  • Silent switching – no contact bounce, ideal for sensitive environments
  • Fast response and long electrical life
  • Compact design for easy panel integration
  • Fully opto-isolated input/output for safe signal control
  • Rated current options from 10A to 100A
  • Zero-cross switching for stable control of resistive loads
  • Suitable for industrial automation, temperature controllers and AC load switching

Works with

The parts that go into the same panel and are usually ordered with it.

Ordering & Selection Guide

SSR + current + input + output voltage + optional H (480V) + optional R (random). Example: SSR-40DA-H-R.

SSRProduct
40Output current
DInput method
AOutput voltage
HVoltage range
RControl method

Output current

10A25A40A50A60A80A100A

Input method

D
4–32VDC
A
80–250VAC
L
4–20mA
V
Variable resistor

Output voltage

A
AC output
D
DC output

Voltage range

H(480V)
High-voltage type: 90–480VAC load
—
Standard type (24–380VAC): no code

Control method

R
Random control (phase-angle switching)
—
Zero-cross control: no code

Worked example

SSR-40DA-H-R

Single-phase solid state module

  • Standard-voltage zero-cross units omit H and R (e.g. SSR-40DA).
  • Current code is rated load current — derate for continuous resistive loads and pair with a heatsink.

Heat sink sizing by relay current

An SSR drops about 1.6 V whatever the load, so the heat it makes is the current times that drop: 40 A is roughly 64 W inside a box the size of a matchbox. The relay's rating only holds with a sink under it, and the sink has to be at or below the thermal resistance in this table.

Relay currentHeat in the relayHeat sink at or belowMounting
10 A16 W≤ 5.0 °C/WPlate 80 × 50 mm
15 A24 W≤ 3.0 °C/WPlate 100 × 60 mm
25 A40 W≤ 2.0 °C/WFinned 100 × 80 mm
40 A64 W≤ 1.2 °C/WFinned 120 × 100 mm
60 A96 W≤ 0.8 °C/WFinned 150 × 120 mm, fan assisted
80 A128 W≤ 0.6 °C/WFinned 200 × 120 mm, fan assisted
100 A160 W≤ 0.45 °C/WFinned 250 × 120 mm, forced air

Figures assume an ambient of 40 °C, a junction limit of 125 °C and thermal paste between relay and sink. Above 40 °C ambient, derate the current by about 1 % per °C, or fit the next size of sink. A relay mounted without a sink carries a fraction of its rating.

Selecting a solid state relay

Three decisions, in this order: the control mode, the current, the heat sink. Getting them out of order is how a 40A relay ends up switching a 25A load without a heat sink and dies in a month.

1. Choose the control mode

The suffix after the current rating says what does the switching and what it switches.

SuffixControl / load
AAAC control, AC load
DADC control, AC load
DDDC control, DC load
VAPotentiometer control, AC load
LA4–20mA proportional input, AC load
VD0–10VDC proportional input, AC load

2. Size the current

The rated current on the label is not the current you may switch. The coefficient depends on the load: 0.5 for a resistive load, 0.15 for an inductive one.

load current ÷ coefficient = relay current

relay current × coefficient = load current

0.5 — resistive load

0.15 — inductive load

Worked example

A 5A resistive oven needs 5 ÷ 0.5 = 10A, which is an SSR-10DA. The same current on an inductive load needs 5 ÷ 0.15 = 33A, so the 40A version.

3. Choose the heat sink

I-501-ph ≤ 15Acompact single-phase block
W-70 / TH-76 / D-741-ph ≤ 40Awide base or TS35 DIN rail
W-100 / T-80 / Ic1-ph ≤ 60Awide or tall fins (optional DIN base on T-80)
T-110 / Ib / E-1051-ph ≤ 80Aheavy single-phase (E-130 up to 120A)
E-52 / H-110 / H-1503-ph ≤ 40–80Athree-phase / industrial; H-series fits 80×80×30mm fan
F-120 / Y-80–Y-1503-ph 100–200Aindustrial up to 250A; F-120 fits 90×90×30mm fan
See all 11 heat sink profile families and dimensions →
Aluminium extrusion heat sinks for SSR modulesAluminium extrusion heat sinks for SSR modules

Before you mount it

An SSR gets hot. Above 10A it must go on a heat sink, with thermal grease between the baseplate and the sink; above 60A add forced air.

Estimate an SSR rating and heat-sink starting point →

Labels and terminals

The front carries six things worth reading before the relay goes into a panel: the brand, the model, the load voltage, the control voltage, the work indicator and the four terminal screws. Load sits on positions 1 and 2, control on 3 and 4 — the pairs are at opposite ends of the body so the mains side and the signal side cannot be confused.

1243SOLID STATE RELAY(PRE-CONDITIONED)SSR-10DAMADE IN CHINABEIJING, CHINA · SINCE 2005CONTROL 3–32VDC1 ~~ 2OUTPUT24–480VACBrand markingModelControl input voltageLoad voltageWork indicator (LED)Terminal screws

Dimensions & Wiring Diagram

SSR-DA Series solid state relay dimensions (57.0L x 44W x 30H mm) and internal wiring diagram

Supply & OEM

Available with your logoMOQ 20 units·Lead time on quotation·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.