ST3PC Time Relay

The plug-in version with an instantaneous contact alongside the delayed one, for the machines that need a contact to close the moment the timer is energ.

ST3PC analog time relay, the same plug-in case as the ST3PA with the mode fixed by the model letter
ST3PC: the ST3PA case with the mode fixed at on-delay plus an instantaneous contact. Same dial, same 0.05 s to 24 h scale, same eight-pin socket.
Panel cut-out
50.5 × 40.5 mm with the socket fitted
Working mode
On-delay, with one instantaneous contact
Contacts
One delayed and one instantaneous changeover
Contact rating
AC 250 V, 3 A; DC 28 V, 5 A
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

Working modeOn-delay, with one instantaneous contact
ContactsOne delayed and one instantaneous changeover
Contact ratingAC 250 V, 3 A; DC 28 V, 5 A
Supply12, 24, 36, 48, 110, 220 or 380 V AC 50/60 Hz; 12 or 24 V DC
Body55 × 41 × 84 mm
Panel cut-out50.5 × 40.5 mm with the socket fitted
MountingPanel or DIN rail, with the matching socket
Supply tolerance−15% to +10% at AC, −10% to +10% at DC of the rated supply
Power3 W max
SettingKnob
IndicationLED
Repeat accuracy±0.3%, ±0.05 sec
Setting error±0.5%, ±0.05 sec
Termination8 pins
Matched socketPF083A , PF085A , US-08
Mechanical life1,000,000 operations
Electrical life1×10^5 operations
Temperature0 to 50 ℃
Humidity95% RH max, non-condensing

Product overview

Part no. SE-ST3PC

Also known as: ST3PC timer relay · ST3PC time relay · ST3PC relé temporizador

The plug-in version with an instantaneous contact alongside the delayed one, for the machines that need a contact to close the moment the timer is energised and a second one after the set time.

Key features

  • On-delay, with one instantaneous contact
  • AC 250 V, 3 A; DC 28 V, 5 A
  • Panel or DIN rail, with the matching socket

Works with

The parts that go into the same panel and are usually ordered with it.

Models in this series

The order codes below differ in contact arrangement and delay range; everything else is shared.

Model numberContactsDelay timeVoltageBody (mm)Cutout / mounting
ST3PC-AOn delay SPDT and instantaneous SPDT0.5s/5s/30s/3minAC 12–380 V, 12/24 V DC50 × 40 × 5850.5 × 40.5 with socket
ST3PC-BOn delay SPDT and instantaneous SPDT1s/10s/60s/6minAC 12–380 V, 12/24 V DC50 × 40 × 5850.5 × 40.5 with socket
ST3PC-COn delay SPDT and instantaneous SPDT5s/50s/5min/30minAC 12–380 V, 12/24 V DC50 × 40 × 5850.5 × 40.5 with socket
ST3PC-DOn delay SPDT and instantaneous SPDT10s/100s/10min/60minAC 12–380 V, 12/24 V DC50 × 40 × 5850.5 × 40.5 with socket
ST3PC-EOn delay SPDT and instantaneous SPDT60s/10min/60min/6hAC 12–380 V, 12/24 V DC50 × 40 × 5850.5 × 40.5 with socket
ST3PC-FOn delay SPDT and instantaneous SPDT2min/20min/2h/12hAC 12–380 V, 12/24 V DC50 × 40 × 5850.5 × 40.5 with socket
ST3PC-GOn delay SPDT and instantaneous SPDT4min/40min/4h/24hAC 12–380 V, 12/24 V DC50 × 40 × 5850.5 × 40.5 with socket

Which one, within the series

  • Pick the contact arrangement the panel needs, then the delay range that covers the duty

Shared by the series

  • Contact rating is AC 250 V, 3 A resistive across the family
  • Timing accuracy of one percent or better
  • Supply is AC 12–380 V or DC 12–24 V on the same unit where the sheet allows it
  • Panel or socket mounting, with a 35 mm rail adapter where the body allows it

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related guides

Related models

All Timer Relays

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.