Temperature Controllers
TC4 Series PID Temperature Controller
Panel-mounted PID control for industrial heating. Match the panel cut-out and output to your system.

- Panel size
- 48×48 / 48×96 / 96×48 / 72×72 / 96×96mm
- Panel cutout
- 45×45 / 45×92 / 92×45 / 68×68 / 92×92mm
- Control output
- Relay + SSR drive (W), voltage output (1U/2U), current output (1A/2A), SCR trigger (T/P)
- Supply voltage
- 100–240VAC (code 2) or 24VDC (code 4)
Technical specifications
| Series | TC4 Series (panel-mount PID temperature controller) |
|---|---|
| Models | TC4S / TC4H / TC4W / TC4M / TC4L |
| Display | 4-digit dual-row LED: red PV + green SV |
| Front panel | Indicators: OUT (heating), AT (cooling), ALM1 (upper alarm), ALM2 (lower alarm). Keys: SET (menu and confirm; hold 3s for level 1, 5s for level 2), ◀ (digit select; hold to enter auto-tuning and toggle °C/°F), ∨ and ∧ (value down and up) |
| Control method | ON/OFF, position control, PID |
| Input | Thermocouple K/J/E/T/N/S/R/B; RTD Pt100, Cu50; linear 0–20mA, 4–20mA, 0–5V, 1–5V |
| Temperature range | 0–400°C default, 0–1370°C maximum |
| Control output | Relay + SSR drive (W), voltage output (1U/2U), current output (1A/2A), SCR trigger (T/P) |
| Relay contact rating | 10A contact, 800W resistive load |
| Alarm output | 0, 1 or 2 alarms (code 0 / 1 / 2) |
| Communication | RS485 Modbus RTU optional (code C) |
| Supply voltage | 100–240VAC (code 2) or 24VDC (code 4) |
| Power consumption | Max. 8VA |
| Accuracy | ±0.5% FS |
| Resolution | 1°C or 0.1°C, selectable |
| Sampling period | 100ms |
| Relay life | Mechanical >2,500,000 operations; electrical >100,000 operations |
| Dielectric strength | 2000VAC, 50/60Hz, 1 minute |
| Memory retention | Approx. 10 years |
| Operating environment | -5 to 40°C; storage -10 to 50°C; 35–85% RH |
| Ingress protection | IP65 |
| Certification | CE |
| Panel size | 48×48 / 48×96 / 96×48 / 72×72 / 96×96mm |
| Panel cutout | 45×45 / 45×92 / 92×45 / 68×68 / 92×92mm |
| Housing | ABS, black |
| Weight | 0.5kg (shipping weight, one packed unit) |
| Dimensions (depth) | 75mm body + 4mm bezel |
Product overview
Part no. SE-TC4
Also known as: Autonics TC4 · TC4 temperature controller · TC4 PID controller · TC4 controlador de temperatura
TC4 Series PID Temperature Controller is a digital temperature control instrument designed for accurate temperature measurement and stable process control. It supports multiple panel sizes, thermocouple input, RTD input, relay output, SSR drive output, 4–20mA control output, optional 4–20mA transmission output and RS485 Modbus communication.
Key features
- PID control and position control available
- Digital PV / SV temperature display
- Multiple panel sizes: S / H / W / M / L
- Supports thermocouple input: K, E, J, S, R, B, N, T
- Supports RTD input: Pt100, Cu50
- Relay output, SSR output or 4–20mA control output optional
- One or two alarm outputs available
- Optional 4–20mA transmission output
- Optional RS485 Modbus communication
- Suitable for heating equipment and automation control systems
Works with
The parts that go into the same panel and are usually ordered with it.
Ordering & Selection Guide
The TC4 is specified as TC, then the type digit, the size, the output, the alarm count, the input, the power supply and an optional communication code, in that order. The type digit names the family — 4 for the red and green display, 5 for the white and green — so a TC4 version always starts TC4 and leaves the communication position blank, because RS485 is not available on this family.
FormatTC[4/5]-[SIZE][OUTPUT][ALARM][INPUT]-[POWER]*[COMM.]
Product type
- 4
- 4-digit dual-row LED, red and green (TC4)
- 5
- 4-digit dual-row LED, white and green (TC5)
Size
- S
- DIN W48 × H48 mm
- H
- DIN W48 × H96 mm
- W
- DIN W96 × H48 mm
- M
- DIN W72 × H72 mm
- L
- DIN W96 × H96 mm
Output specification
- R
- Relay contact output
- S
- SSR solid-state relay output
- W
- Relay contact + SSR output
- 1U
- Voltage controlled output
- 2U
- Temperature variable voltage output
- 1A
- Current controlled output
- 2A
- Temperature variable current output
- 1T
- SCR zero-crossing output
- 2T
- SCR phase-shift output
Alarm output
- 0
- No alarm
- 1
- One alarm
- 2
- Two alarms
Input specification
- T
- Thermocouple (K, E, J)
- R
- Thermal resistance (Pt100, Cu50)
- T/R
- Thermocouple (K, E, J) / thermal resistance (Pt100, Cu50)
- A
- Linear current (0–20 mA, 4–20 mA)
- U
- Linear voltage (0–5 V, 0–10 V)
Power supply
- Blank
- 220 VAC, 50/60 Hz
- 2
- 100–240 VAC/DC
- 4
- 24 VAC/DC
Communication
- Blank
- No communication
- C
- RS485 Modbus RTU — TC5 only
Examples
- The size letters follow the DIN face: S is 48×48mm, H 48×96mm, W 96×48mm, M 72×72mm and L 96×96mm.
- A blank power position is 220 VAC; 2 is 100–240 VAC/DC and 4 is 24 VAC/DC. A blank communication position means no RS485, and on the TC4 it is always blank.
- The star before the communication code is the supplier's own separator, not part of the model number.
Documents for this family
- TC4H / M / L / W wiring1.8 MB · 2026-11-18
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 3 years
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Frequently asked questions
What panel size and cut-out does the TC4 need?
48×48 / 48×96 / 96×48 / 72×72 / 96×96mm. The cut-out is 45×45 / 45×92 / 92×45 / 68×68 / 92×92mm
Which sensors can the TC4 read?
Thermocouple K/J/E/T/N/S/R/B; RTD Pt100, Cu50; linear 0–20mA, 4–20mA, 0–5V, 1–5V
What output options does the TC4 have?
Relay + SSR drive (W), voltage output (1U/2U), current output (1A/2A), SCR trigger (T/P)
What supply voltage does the TC4 need?
100–240VAC (code 2) or 24VDC (code 4)
How accurate is the TC4?
±0.5% FS, at 1°C or 0.1°C, selectable resolution
Does the TC4 have alarm outputs?
0, 1 or 2 alarms (code 0 / 1 / 2)
Related guides
TC4 Series PID Temperature Controller: Model Code Breakdown, Outputs and RS485 Setup
How to read a TC4 model code, which sensor inputs and control outputs are available across TC4S/H/W/M/L, what the RS485 Modbus option adds, and the checks to run at commissioning.
Read guide Product Updates · 2025-04-11TCN4 Series PID Temperature Controller: Model Codes, Inputs, Outputs and Commissioning
A working reference for engineers specifying or commissioning a TCN4 series digital PID temperature controller: how the four panel sizes differ, which sensor inputs are accepted,…
Read guide Product Updates · 2024-03-18TC4-W PID Temperature Controller: Panel Data, Outputs and Retrofit Notes
Panel and cutout dimensions, electrical specification, output selection and retrofit checks for the TC4-W horizontal PID temperature controller within the TC4 family.
Read guideRelated models
All Temperature Controllers
TC4H Digital PID Temperature Controller
SE-TC4H
48×96mm (1/8 DIN) · 45×92mm · 75mm total, 71mm behind the panel
View details
TC4L Digital PID Temperature Controller
SE-TC4L
96×96mm (1/4 DIN) · 92×92mm · 75mm total, 71mm behind the panel
View details
TC4W Digital PID Temperature Controller
SE-TC4W
96×48mm (1/8 DIN) · 92×45mm · 75mm total, 71mm behind the panel
View details
TC4S Digital PID Temperature Controller
SE-TC4S
48×48mm (1/16 DIN) · 45×45mm · 75mm total, 71mm behind the panel
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.