Temperature Controllers

TC7 Series 32-Segment Programmable PID Temperature Controller

TC7 panel-mount PID controller: 32-segment programmer, universal TC/RTD/mA/V input, relay + SSR drive output, five bezel sizes.

TC7 series universal-input PID temperature controllers in five bezel sizes
TC7-S (48×48mm) · TC7-H (48×96mm) · TC7-M (72×72mm) · TC7-L (96×96mm) · TC7-W (96×48mm)
Panel size
48×48 / 48×96 / 72×72 / 96×96 / 96×48mm
Panel cutout
45×45 / 45×92 / 68×68 / 92×92 / 92×45mm
Control output
Relay plus 12VDC SSR drive on every variant, switchable from the front panel; 4–20mA or 0–10V analogue output to order
Supply voltage
100–240VAC/DC, 50/60Hz; 24VAC/DC on the 4 supply code
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Order codes of this series

This series is built in more than one version. Each has its own page with the complete order code, the output stage it carries and what that stage can switch; the case, the cut-out and the supply stay the same.

Order codeOutput stageBezel (mm)Cut-outOpen
TC7-S W1G-2Relay plus solid-state dual output48 × 48 × 7545 × 45TC7-S W1G-2 →
TC7-S W2G-2Two outputs and two alarm relays48 × 48 × 7545 × 45TC7-S W2G-2 →
TC7-H W1G-2Relay plus solid-state dual output48 × 96 × 7545 × 92TC7-H W1G-2 →
TC7-H W2G-2Two outputs and two alarm relays48 × 96 × 7545 × 92TC7-H W2G-2 →
TC7-M W1G-2Relay plus solid-state dual output72 × 72 × 7568 × 68TC7-M W1G-2 →
TC7-M W2G-2Two outputs and two alarm relays72 × 72 × 7568 × 68TC7-M W2G-2 →
TC7-L W1G-2Relay plus solid-state dual output96 × 96 × 7592 × 92TC7-L W1G-2 →
TC7-L W2G-2Two outputs and two alarm relays96 × 96 × 7592 × 92TC7-L W2G-2 →
TC7-W W1G-2Relay plus solid-state dual output96 × 48 × 7592 × 45TC7-W W1G-2 →
TC7-W W2G-2Two outputs and two alarm relays96 × 48 × 7592 × 45TC7-W W2G-2 →

Technical specifications

SeriesTC7 Series (universal-input panel-mount PID temperature controller)
ModelsTC7-S / TC7-H / TC7-M / TC7-L / TC7-W
Order codeW1G-2, read as W + 1 + G + 2: relay and SSR drive output, one alarm, universal input, 100–240VAC/DC supply. W2G-2 adds a second alarm, and a C in the sixth position adds RS485.
DisplayTwo 4-digit LED rows, PV above SV
Control methodPID with auto-tuning, plus ON/OFF
Program control32-segment programmer (PRON 0–32): 0 runs fixed-setpoint control, and 1–32 run setpoint/time pairs SP1–ST1 through SP32–ST32
Ramp rate (SPR)0–999.9 °C/min
Segment time0.1–999.9 minutes or hours, or 1–9999 seconds or minutes, selected by the STCY time-unit digit
Timer mode (STCY)Four independent digits ABCD — start mode, count direction, end action and time unit. Factory default 2020.
Start deviation (STTP)3°C
Hold value (ENSP)100
Program status displaySETX in the upper row shows the running segment number; the ALM2 lamp flashes while timing and stays lit when the timer ends
InputK, J, R, S, B, E, N, T thermocouple; Pt100 and Cu50 RTD; 0–20mA and 4–20mA; 0–5V and 1–5V
Control outputRelay plus 12VDC SSR drive on every variant, switchable from the front panel; 4–20mA or 0–10V analogue output to order
Relay contact rating10A contact, 800W resistive load
Alarm outputOne alarm as standard (ALM1); the W2G-2 code adds ALM2
Soft startOutput held to 25% of full power for the soft-start window, so a cold heater is not switched on at 100% and the element is not thermally shocked
Temperature unit°C or °F, selected on the front panel
CommunicationRS485 Modbus RTU to order (C in the order code)
Supply voltage100–240VAC/DC, 50/60Hz; 24VAC/DC on the 4 supply code
Accuracy±0.5°C
Display resolution0.1°C
Panel size48×48 / 48×96 / 72×72 / 96×96 / 96×48mm
Panel cutout45×45 / 45×92 / 68×68 / 92×92 / 92×45mm
Dimensions (depth)75mm behind the bezel
HousingABS case with a perforated top and side vents
MountingPanel mount, base-bolt clamp
CertificationCE
Typical applicationsOvens, incubators, injection moulding machines, greenhouses, agricultural drying rooms and general machine temperature control

Product overview

Part no. SE-TC7

Also known as: TC7 temperature controller · TC7 PID controller · TC7 controlador de temperatura

The TC7 is the programmer in the range: 32 segments, each pairing a setpoint with a segment time, run back to back at an adjustable ramp rate so an oven or furnace follows a heating profile instead of sitting at one temperature. Segment 0 switches the programmer off and leaves a plain fixed-setpoint PID controller, so the same instrument covers both jobs. Underneath the programmer sits one universal input board — K, J, R, S, B, E, N and T thermocouples, Pt100 and Cu50 RTDs, 0–20mA and 4–20mA current loops, 0–5V and 1–5V signals — so a single part number covers a machine that mixes sensor types. Every variant carries a relay output and a 12VDC SSR drive together and switches between them from the keypad, and the 25% soft start holds the first seconds of heating down so a cold element is not hit at full power. Five bezel sizes run from 48×48 to 96×48mm, all 75mm deep.

Key features

  • 32-segment programmer: each segment pairs a setpoint with a segment time, and up to 32 run back to back as a single heating profile
  • Ramp rate in °C per minute on every segment, so the profile climbs at a controlled slope instead of stepping to the setpoint
  • Programmable timer: start on temperature, on the keypad or at power-on; count up or down; finish by cutting the heating output, holding at the ENSP value or holding the last segment setpoint
  • Segment 0 turns the programmer off and leaves a fixed-setpoint PID controller
  • Universal input: K, J, R, S, B, E, N, T thermocouple, Pt100 and Cu50 RTD, 0–20mA and 4–20mA, 0–5V and 1–5V
  • Relay output and 12VDC SSR drive fitted together, switchable from the keypad
  • PID with auto-tuning, plus ON/OFF for simple on-off loads
  • 25% soft start protects a cold heater from full-power inrush
  • Five bezel sizes — 48×48, 48×96, 72×72, 96×96 and 96×48mm — all 75mm deep
  • RS485 Modbus RTU to order for PLC or SCADA integration

Works with

The parts that go into the same panel and are usually ordered with it.

32-segment program control

The TC7 runs a heating profile, not just a setpoint. A profile is a list of segments — climb to this temperature in this many minutes, hold it for this long, then move on — and the controller walks the list on its own.

32program segments

0–999.9 °C/min

ramp rate per segment

0 = fixed setpoint

PRON 0–32. Each of the 32 segments holds a setpoint and a segment time, so one instrument can run a full ramp-and-hold cycle without an external PLC.

  • Each segment pairs a setpoint (SP) with a segment time (ST), and segment 0 switches the programmer off and leaves a fixed-setpoint controller.
  • Ramp rate (SPR) sets how fast a segment climbs, in °C per minute. Leave it at 0 and the controller steps straight to the segment setpoint instead of ramping.
  • Start mode decides when the clock starts: on the keypad, once the measured value reaches the setpoint minus the start deviation (STTP), or at power-on.
  • End action decides what happens after the last segment: cut the heating output, hold at the hold value (ENSP), or hold the last segment setpoint.
  • While a program runs, the upper row shows SETX with the running segment number and the ALM2 lamp flashes; it stays lit once the timer ends.
SP1SP2SP3ENSPprogram endtemperaturetime

STCY — four digits, four decisions

The timer behaviour is packed into one four-digit setting, ABCD. The factory default is 2020: temperature start, count up, hold at the last segment setpoint, minutes in 0.1 steps.

AStart modethousands
2Temperature start — timing begins once PV reaches SP − STTP
3Key and temperature combined
4Power-on start
otherKey start
BCount directionhundreds
1Count down from the set time to zero
otherCount up from zero to the set time
CEnd actiontens
1Heating output off
2Hold at the ENSP value
otherHold the last segment setpoint
DTime unitunits
00.1–999.9 minutes
10.1–999.9 hours
21–9999 seconds
31–9999 minutes

DefaultsSTTP start deviation 3°C · ENSP hold value 100

Ordering & Selection Guide

Specified as TC7-[bezel] followed by output, alarm, input, supply, and RS485 — e.g. TC7-S W1G2C (48×48mm, relay + SSR, 1 alarm, universal input, 100–240VAC/DC, RS485).

TC7Series
SBezel / model
WControl output
1Alarm
GInput
2Supply
CComm (RS485)

Bezel size

S
48×48×75mm · 45×45mm cutout
H
48×96×75mm · 45×92mm cutout
M
72×72×75mm · 68×68mm cutout
L
96×96×75mm · 92×92mm cutout
W
96×48×75mm · 92×45mm cutout

Control output

W
Relay contact and SSR drive, fitted together and switched from the keypad

Alarm outputs

1
One alarm relay
2
Two alarm relays

Input type

G
Universal: thermocouple K, E, J, N, T, S, R, B; RTD Pt100 and Cu50; 0–20mA and 4–20mA; 0–5V and 1–5V

Supply voltage

2
100–240VAC/DC
4
24VAC/DC

Communication

—
No RS485
C
RS485 Modbus RTU

Worked example

TC7Bezel sizeSControl outputWAlarm outputs1Input typeGSupply voltage2CommunicationC

48×48mm bezel, relay plus SSR drive, one alarm, universal input, 100–240VAC/DC supply, RS485 Modbus RTU.

  • Shorthand “W1G-2” means output W, 1 alarm, universal input G, 100–240VAC/DC supply 2.
  • Code 2 in supply is 100–240VAC/DC; code 4 is 24VAC/DC. Trailing C adds RS485 Modbus RTU.

Wiring and control loop

The TC7 switches the heating load two ways from the same instrument: a 10A relay contact that switches the load directly, and a 12VDC SSR drive that fires an external solid-state relay for longer life on resistive heaters. A universal input takes the thermocouple or RTD, one or two alarm relays flag a fault, and the optional RS485 port drops the instrument onto a Modbus RTU network.

Terminal block · 14 numbered screw terminals in two columns, 1–7 and 8–141234567891011121314ABB+Power100–240VAC1–2SSR drive12VDC3–4Relay OUT10A / 800W5–7Alarm 1ALM18–9Spare10–11InputTC / RTD / AI12–14TC7-H W1G-2

The relay contact is rated 10A / 800W resistive. Size the load and any external SSR so the switched current stays within that rating; keep the heater well below the limit for long-term reliability.

Dimensions and panel cutout

Five bezel sizes share the same 75mm depth behind the panel and a base-bolt clamp. Pick the face that fits the cutout you already have; the depth and mounting method are identical across the family.

ModelFace (mm)Cutout (mm)Depth
TC7-S48 × 4845 × 4575mm
TC7-H48 × 9645 × 9275mm
TC7-M72 × 7268 × 6875mm
TC7-L96 × 9692 × 9275mm
TC7-W96 × 4892 × 4575mm

Applications and version

A panel-mount PID controller with a 32-segment programmer suits any process that needs a ramp-and-hold temperature profile rather than a single setpoint — ageing ovens, incubators, plastic injection and agricultural drying among them.

Typical uses

  • Curing ovens and industrial ovens
  • Incubators and environmental chambers
  • Plastic injection moulding machines
  • Greenhouses and controlled cultivation
  • Agricultural drying rooms
  • General machine temperature control

What the version gives you

  • Dual 4-digit LED: process value above, setpoint below, with °C/°F, OUT, AT and alarm lamps
  • Relay and SSR drive switchable from the keypad — pick the switching method without opening the case
  • 32-segment programmer runs a full ramp-and-hold cycle on its own, with no external PLC
  • 25% soft start limits inrush so a cold heater is not shocked at switch-on
  • Universal input covers the common thermocouples, RTDs and analogue signals in one instrument
  • Optional RS485 Modbus RTU for setpoint writing and data logging from a PLC or SCADA

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What panel size and cut-out does the TC7 need?

48×48 / 48×96 / 72×72 / 96×96 / 96×48mm. The cut-out is 45×45 / 45×92 / 68×68 / 92×92 / 92×45mm

Which sensors can the TC7 read?

K, J, R, S, B, E, N, T thermocouple; Pt100 and Cu50 RTD; 0–20mA and 4–20mA; 0–5V and 1–5V

What output options does the TC7 have?

Relay plus 12VDC SSR drive on every variant, switchable from the front panel; 4–20mA or 0–10V analogue output to order

What supply voltage does the TC7 need?

100–240VAC/DC, 50/60Hz; 24VAC/DC on the 4 supply code

How accurate is the TC7?

±0.5°C, at 0.1°C resolution

Does the TC7 have alarm outputs?

One alarm as standard (ALM1); the W2G-2 code adds ALM2

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.