Temperature Controllers

TED-2001 and TEA-2001 Pointer Temperature Controllers

Pointer temperature controllers for ovens and griddles: TED-2001 / TEA-2001 in TED 72×72 mm, TEA 96×96 mm panels, with K or E thermocouple input, relay contact output and a ±2.5% FS scale.

TED-2001 and TEA-2001 pointer temperature controllers side by side
TED-2001 on the left in a 72 square front, TEA-2001 on the right in a 96.
Output
relay contact output
Input
K or E thermocouple
Models
TED-2001 / TEA-2001
Panel sizes
TED 72×72 mm, TEA 96×96 mm
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesTED / TEA pointer temperature controller
ModelsTED-2001 / TEA-2001
Panel sizesTED 72×72 mm, TEA 96×96 mm
Ranges300 °C or 400 °C on the TED, 400 °C on the TEA
InputK or E thermocouple
Outputrelay contact output
Controlon/off with a fixed 2 °C differential
Accuracy±2.5% FS
Supply220 VAC, 50/60 Hz, with a 380 VAC build on request
Operating environment0–50 °C, 30–85% RH, no corrosive gas

Product overview

Part no. SE-TED-TEAindustry model TED-TEA

Also known as: TED-2001 · TEA-2001 · pointer-scale On/Off temperature controller

Two pointer instruments for ovens and griddles. The temperature is read on a moving-coil scale, the setpoint is a printed dial, and a relay switches the heater across a fixed differential. Nothing to program and nothing to misread in a dark cabinet.

Key features

  • TED-2001 / TEA-2001
  • 300 °C or 400 °C on the TED, 400 °C on the TEA
  • K or E thermocouple input
  • relay contact output, on/off with a fixed 2 °C differential
  • ±2.5% FS scale accuracy, 220 VAC, 50/60 Hz, with a 380 VAC build on request

Works with

The parts that go into the same panel and are usually ordered with it.

Compatible sensors & outputs

also supplied as pointer-scale on/off temperature controller, analog dial panel thermostat

Output types and what goes with them

OutputRatingOrder with it
Dry-contact relay250 VAC / 3 A (resistive load ≤ 750 W); drives an external contactor for larger heatersCJX2 AC contactor

Two bezels, no display

These are pointer instruments: the temperature is read off a scale, the setpoint is a printed dial, and no number is ever shown digit by digit. That is what makes them the cheapest thing in the panel and the easiest for an operator to set without a manual.

ModelPanel W×H (mm)Ranges
TED-200172 × 72 mm300 °C or 400 °C
TEA-200196 × 96 mm (1/4 DIN)400 °C

What is ordered

Each model is built to one combination of range, thermocouple type and supply. The code on the label stays the same, so the three choices have to be named on the order line.

  • Range300 °C or 400 °C on the TED; 400 °C on the TEA
  • ThermocoupleK or E
  • Supply220 VAC as standard, 380 VAC on request

Reading it on the machine

  • The pointer shows the measured temperature; the setpoint is where the dial's own mark sits, and the two are separate — moving the knob does not move the pointer
  • Two lamps: green on while the heater is being powered, red once the setpoint is reached
  • The switching differential is a fixed two degrees, so the temperature holds in a band either side of the mark rather than sitting on it
  • On a 300 degree version the scale runs to 300 and a 400 degree job needs the other version, not a re-set of the dial

Wiring

Ten terminals in two rows. The thermocouple lands on 1 and 2, the relay on 6 and 7 and 8, and the supply on 9 and 10. On this model the low side of the relay output is bridged to neutral, which is what makes it a single-pole switch rather than a floating contact.

TED-2001 wiring through an AC contactor, and the terminal arrangement
TerminalFunction
1 · 2Thermocouple — red to 1, blue to 2
6Relay common (High side label)
7Relay common terminal (Com)
8Relay low, bridged to 9
9Neutral (N)
10Live (L)

220 V and 380 V versions wire the same way; only the transformer inside the case differs, so a 380 V unit drops into a panel wired for 220 V without changing the terminal plan.

Against the TEL pointer

Both are pointer controllers for ovens; the TEL96 is the larger 96 square body with the dial below the scale, while these two split into a 72 and a 96 with the scale above. Where a panel already has a 72 cut-out, the TED is the one that fits without opening it out.

TED / TEATEL96
Bezels72 and 96 square96 square
Readoutpointer scalepointer scale or LED on the 9001
Ranges300 or 400 °C400 °C
Supply220 V or 380 V220 V or 380 V

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What panel size and cut-out does the TED-2001 need?

TED 72×72 mm, TEA 96×96 mm

Which sensors can the TED-2001 read?

K or E thermocouple

What output options does the TED-2001 have?

relay contact output

What supply voltage does the TED-2001 need?

220 VAC, 50/60 Hz, with a 380 VAC build on request

How accurate is the TED-2001?

±2.5% FS

What is the temperature range?

300 °C or 400 °C on the TED, 400 °C on the TEA

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.