Solid State Relays & SCR Power Modules
SCR-100 and SCR-700 Voltage Regulators
Panel voltage regulators with a two-row voltmeter display and a firing output for an external thyristor, in 48 and 72 square fronts.

- Output
- A firing signal for an external thyristor, not the load current itself
- Models
- SCR-100, also supplied as ZKG-2000, and SCR-700
- Panel sizes
- 48×48 mm on the SCR-100, 72×72 mm on the SCR-700
- Panel cutouts
- 45×45 mm and 68×68 mm
Technical specifications
| Product | Panel voltage regulator with a digital display, for resistive heating |
|---|---|
| Models | SCR-100, also supplied as ZKG-2000, and SCR-700 |
| Panel sizes | 48×48 mm on the SCR-100, 72×72 mm on the SCR-700 |
| Panel cutouts | 45×45 mm and 68×68 mm |
| Depth behind panel | 90mm and 112mm behind the panel |
| Display | Two rows: output voltage on PV, setpoint on SV, in volts |
| Front keys | Setpoint and output adjusted from the front keys |
| Supply | 220 VAC ±15%, 50 Hz, about 3 W |
| Output | A firing signal for an external thyristor, not the load current itself |
| Output voltage | 0–220 VAC setting range; the load voltage actually reached is limited by the supply |
| Gate pulse | At least 3 V amplitude and 50 µs width into a 20 Ω gate |
| Conduction angle | Phase-angle firing up to at least 150° |
| Terminals | Seven, with the fuse on the incoming line and a gate terminal for the thyristor |
| Typical use | Bottle-blowing machines, extruder barrels, sealing bars and other manual heating loops |
| Operating environment | 0–50 °C, up to 85% RH, non-condensing, no corrosive gas |
| Weight | 150 g for the 48×48 mm unit |
| Thyristor to match | The unit fires an external thyristor rather than carrying the load; size that device to the heater current and its heatsink to the cabinet |
Product overview
Part no. SE-100-700industry model 100-700
Also known as: SCR-100 / SCR-700 Voltage Regulator · Phase-Angle SCR Controller
A manual voltage regulator for a heating loop where the operator sets the heat and watches the product. The output voltage is on the display and the setpoint below it, so a turn of a key changes the heat directly. The regulator drives an external thyristor rather than switching the load itself.
Key features
- SCR-100, also supplied as ZKG-2000, and SCR-700
- Panels 48×48 mm on the SCR-100, 72×72 mm on the SCR-700, cut-outs 45×45 mm and 68×68 mm
- Two rows: output voltage on PV, setpoint on SV, in volts
- A firing signal for an external thyristor, not the load current itself
- Seven terminals, fuse on the incoming line, gate output for the thyristor
Works with
The parts that go into the same panel and are usually ordered with it.
PID controller (4–20 mA)
SE-TC4
Order the linear 4–20 mA current-output version to drive this analog power regulator; a pulsed SSR drive output will not regulate it
Matched heat sink
SE-HS-SSR
Size the radiator (and cooling fan for high-current three-phase loads) to the module's operating current
Thermocouple or Pt100
SE-TC-WRNK236
K-type or Pt100 sheathed probe matched to the PID controller input
Two bezels
Same regulator in a 48 and a 72 square front. The panel shows the output voltage on the top row and the setpoint below it, and the two keys raise and lower the setpoint while the machine is running.
| Model | Panel (mm) | Cutout (mm) | Depth (mm) |
|---|---|---|---|
| SCR-100 | 48 × 48 | 45 × 45 | 90 |
| SCR-700 | 72 × 72 | 68 × 68 | 112 |


Terminals and what they drive
The regulator does not switch the load itself: it produces a firing angle for an external thyristor, which is bolted to a heatsink beside it. The rear drawing names the seven terminals and the fuse that sits in the incoming line.

| Terminal | Function |
|---|---|
| 1 | Incoming line through the fuse |
| 2 | Neutral |
| 3 | Spare / not used on the drawing |
| 4 | To the thyristor anode side (A1) |
| 5 | To the thyristor cathode side (A2) |
| 6 | Gate (G) |
| 7 | Load return |
When a voltage regulator, not a controller
A PID controller reads a thermocouple and decides for itself; this one does what the operator sets. On a bottle-blowing machine, an extruder barrel or a sealing bar the operator watches the product and turns the voltage up or down, and that is the whole control loop. It is also the cheaper of the two, and it never fights the operator for the setpoint.
- Output voltage is on the display, so the operator sees what the heater is actually getting rather than a temperature that lags behind
- No sensor is needed, which is one less thing to break in a hot cabinet
- Changing the heat is a key press, not a tuning exercise
- It holds a voltage, not a temperature: if the mains moves, the heater follows it
The same unit under two codes
The 48 square regulator is sold as SCR-100 and as ZKG-2000; they are the same instrument, and the older code is the one moulders ask for. Both run from 220 VAC ±15% and regulate the output from zero to the supply voltage by phase angle, firing an external thyristor that carries the load current.
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related guides
SCR Voltage Regulator Circuit Diagram and Wiring Guide
How to read and apply SCR voltage regulator circuit diagrams for single-phase and three-phase four-wire resistive heating, using the current SCR-100 controller and M1DK…
Read guide Product Updates · 2025-03-28BDTY Single-Phase SCR Voltage Regulator: Signal Options, Sizing and Installation
Control signal options, current sizing from 10A to 400A, wiring and isolation practice, thermal design and commissioning steps for the BDTY single-phase SCR power regulator used…
Read guide Product Updates · 2024-02-06SCR-100 / ZKG-2000 Heating Power Controller: Wiring, Setup and Fault Finding
What the SCR-100 / ZKG-2000 actually controls, how the T1, G, N and L terminals connect to an external pulse-triggered SCR module, panel and cutout data, and how to commission and…
Read guideRelated models
All Solid State Relays & SCR Power Modules
SCR3L Three-Phase Intelligent SCR Voltage Regulator 60A–200A
SE-SCR3L
SCR3L Series Three-Phase Intelligent SCR Voltage Regulator is an integrated SCR power control module designed for 380VAC three-phase resistive load…
View details
M1DK / SSR-DV Pulse-Triggered SCR Power Module
SE-M1DK
M1DK / SSR-DV Pulse-Triggered SCR Power Module is a single-phase solid state power module driven by the pulse trigger signal of an SCR heating…
View details
M1DK-80DA SCR Module, 80A
SE-M1DK-80DA
M1DK-80DA Pulse-Triggered SCR Power Module is a single-phase solid state power module driven by the pulse trigger signal of an SCR heating…
View details
SSR-DA Single-Phase SSR — Standard Black Housing, 10A–100A
SE-SSR-DA
SSR-DA Series single-phase solid state relays from Beijing Strong Electric offer fast, silent zero-cross switching for AC resistive loads. Control…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.